Diesel plant sizing and performance analysis of a remote wind-diesel Microgrid

被引:0
|
作者
Katiraei, Farid [1 ]
Abbey, Chad [1 ]
机构
[1] CANMET Energy Technol Ctr Varennes, Nat Resources Canada, 1615 Lionet Boulet Blvd, Quebec City, PQ J3X 1S61, Canada
关键词
autonomous wind-diesel; unit sizing; distributed generation; energy flow; Microgrid;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces an energy-flow model developed for performance analysis and unit sizing of an autonomous wind-diesel Microgrid. A remote community in Canada is used as the study system, for which a medium penetration wind power plant has been integrated into a system served by a diesel plant with three equally sized diesel generators. Based on field observations and monitored data for almost two years of operation, an energy-flow model is developed which incorporates operating constraints and control requirements of the autonomous wind-diesel system. The model is employed to analyze the interaction of wind and diesel power plants in order to identify alternative unit sizing approaches that improve wind-energy absorption rate of the wind plant, fuel savings and overall efficiency of the diesel plant. Optimization criteria for unit sizing of the diesel plant in the presence of the wind farm are discussed and system performance for several configurations based on multiple units with reduced-size diesel unit are investigated. The simulation results from the energy-flow model for two operation scenarios are compared with the field observations and an optimum combination of multiple diesels with reduced-size units is suggested.
引用
收藏
页码:4820 / +
页数:2
相关论文
共 50 条
  • [41] Tuning the Regulators of Wind-Diesel Power Plant Operating on the DC-bus
    Lukutin, Boris V.
    Sarsikeyev, Yermek Zh.
    Surkov, Mikhail A.
    Lyapunov, Danil Yu.
    2014 14TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2014, : 459 - 463
  • [42] Optimal sizing of energy storage devices in wind-diesel systems considering load growth uncertainty
    Nhung Nguyen-Hong
    Huy Nguyen-Due
    2016 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), 2016, : 54 - 59
  • [43] Optimal Design and Control of Wind-Diesel Hybrid Energy Systems for Remote Arctic Mines
    Romero, Alberto
    Carvalho, Monica
    Millar, Dean L.
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2016, 138 (06):
  • [44] Regenerative air energy storage for remote wind-diesel micro-grid communities
    Manchester, Sebastian C.
    Swan, Lukas G.
    Groulx, Dominic
    APPLIED ENERGY, 2015, 137 : 490 - 500
  • [45] Power Quality Estimation in a Remote Wind-Diesel Hybrid Power System in Cartwright, Labrador
    Islam, Sheikh Mominul
    Iqbal, M. Tariq
    ISTANBUL UNIVERSITY-JOURNAL OF ELECTRICAL AND ELECTRONICS ENGINEERING, 2011, 11 (01): : 1319 - 1326
  • [46] Introducing well-being analysis for wind-diesel islanded grid
    Aghaebrahimi, M. R.
    Mehdizadeh, M.
    Heshmati, A.
    Najafi, H. R.
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2013, 23 (08): : 1490 - 1503
  • [47] Power smoothing in a variable speed wind-diesel system
    Cárdenas, R
    Peña, R
    Clare, J
    Asher, G
    PESC'03: 2003 IEEE 34TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 754 - 759
  • [48] Modelling an autonomous wind-diesel system using SIMULINK
    Tomilson, A
    Quaicoe, J
    Gosine, R
    Hinchey, M
    Bose, N
    1997 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, CONFERENCE PROCEEDINGS, VOLS I AND II: ENGINEERING INNOVATION: VOYAGE OF DISCOVERY, 1997, : 35 - 38
  • [49] Ecological Analysis of a Wind-Diesel Hybrid Power System in the South Algeria
    Allali, Khaireddine
    Azzag, El Bahi
    EXERGY FOR A BETTER ENVIRONMENT AND IMPROVED SUSTAINABILITY 2: APPLICATIONS, 2018, : 925 - 934
  • [50] Performance Evaluation of Wind-Diesel Hybrid System with Capacitive Energy Storage System
    Dhundhara, Sandeep
    Verma, Yajvender Pal
    2015 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2015,