Validation of a 5-minute steady state indirect calorimetry protocol for resting energy expenditure in critically ill patients

被引:0
作者
Frankenfield, DC
Sarson, GY
Blosser, SA
Cooney, RN
Smith, JS
机构
[1] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT SURG,HERSHEY,PA 17033
[2] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT ANESTHESIA,HERSHEY,PA 17033
[3] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT MED,HERSHEY,PA 17033
关键词
critical care; nutrition assessment; energy metabolism; nutritional requirements; calorimetry; indirect; oxygen consumption; nutritional support;
D O I
暂无
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: Numerous protocols are used for indirect calorimetry in research and clinical settings. The objective of the current study was to validate in critically ill patients an abbreviated protocol that uses five consecutive stable 1-minute readings of oxygen consumption (VO2), carbon dioxide production (VCO2), and minute ventilation (V-E) in a range of +/- 5%, versus a more standard protocol that uses 30 consecutive stable one minute readings of VO2, VCO2, and V-E in a range of +/- 10%. Methods: Indirect calorimetry was performed on resting, mechanically ventilated, critically ill patients. The first 5-minute period in which coefficients of variation for VO2, VCO2 and V-E were less than or equal to 5% was compared to the first 30-minute period in which coefficients of variation for these variables were less than or equal to 10%. Results: Thirty-four critically ill patients were studied. Twenty four patients (70%) successfully completed both protocols (Success Group). Eighteen percent of subjects completed neither the abbreviated nor the 30 minute protocol, and 12% completed only one protocol (Fail Group). The Success Group was marked by a higher incidence of sedation and/or medical paralysis. There were no significant differences in V-E, VO2, VCO2, respiratory quotient, or energy expenditure between the protocols in the Success Group or the Fail Group. Coefficients of determination (R(2)) for VO2 and VCO2 between the two methods in the Success Group were 0.99. In the Fail Group, R(2) values ranged from 0.75 for VCO2 to 0.91 for VO2. Conclusion: In sedated, mechanically ventilated patients, an indirect calorimetry test of five consecutive 1-minute periods with coefficient of variation less than or equal to 5% is equivalent to a longer test consisting of 30 consecutive 1-minute periods with coefficient of variation less than or equal to 10%.
引用
收藏
页码:397 / 402
页数:6
相关论文
共 16 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BURSZTEIN S, 1989, ENERGY METABOLISM IN, P200
[3]  
CHIOLERO RL, 1993, METABOLIC SUPPORT CR, P95
[4]   MEASURED AND PREDICTED RESTING ENERGY-EXPENDITURE IN CLINICALLY STABLE PATIENTS [J].
FEURER, ID ;
CROSBY, LO ;
MULLEN, JL .
CLINICAL NUTRITION, 1984, 3 (01) :27-34
[5]  
FOSTER GD, 1987, J AM COLL NUTR, V6, P231
[6]  
FRANKENFIELD DC, 1994, CRIT CARE MED, V22, P1796
[7]   OXYGEN-CONSUMPTION AND RESTING METABOLIC-RATE IN SEPSIS, SEPSIS SYNDROME, AND SEPTIC SHOCK [J].
KREYMANN, G ;
GROSSER, S ;
BUGGISCH, P ;
GOTTSCHALL, C ;
MATTHAEI, S ;
GRETEN, H .
CRITICAL CARE MEDICINE, 1993, 21 (07) :1012-1019
[8]   VENTILATION PERFUSION INDEXES DO NOT CORRELATE WITH THE DIFFERENCE BETWEEN OXYGEN-CONSUMPTION MEASURED BY THE FICK PRINCIPLE AND METABOLIC MONITORING SYSTEMS IN CRITICALLY ILL PATIENTS [J].
MYBURGH, JA ;
WEBB, RK ;
WORTHLEY, LIG .
CRITICAL CARE MEDICINE, 1992, 20 (04) :479-482
[9]   A VALIDATION AND COMPARISON STUDY OF 2 METABOLIC MONITORS [J].
PHANG, PT ;
RICH, T ;
RONCO, J .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1990, 14 (03) :259-261
[10]   A RE-EVALUATION OF ENERGY-EXPENDITURE DURING PARENTERAL-NUTRITION [J].
QUEBBEMAN, EJ ;
AUSMAN, RK ;
SCHNEIDER, TC .
ANNALS OF SURGERY, 1982, 195 (03) :282-286