Electroporation-Induced Electrosensitization

被引:83
作者
Pakhomova, Olga N. [1 ]
Gregory, Betsy W. [1 ]
Khorokhorina, Vera A. [1 ]
Bowman, Angela M. [1 ]
Xiao, Shu [1 ,2 ]
Pakhomov, Andrei G. [1 ]
机构
[1] Old Dominion Univ, Frank Reidy Res Ctr Bioelect, Norfolk, VA 23529 USA
[2] Old Dominion Univ, Dept Elect & Comp Engn, Norfolk, VA USA
关键词
ELECTRIC-FIELD THERAPY; PLASMA-MEMBRANE; IRREVERSIBLE ELECTROPORATION; REPETITION FREQUENCY; HIGH-INTENSITY; GENE-TRANSFER; ELECTROCHEMOTHERAPY; CELLS; PULSES; TUMORS;
D O I
10.1371/journal.pone.0017100
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Electroporation is a method of disrupting the integrity of cell membrane by electric pulses (EPs). Electrical modeling is widely employed to explain and study electroporation, but even most advanced models show limited predictive power. No studies have accounted for the biological consequences of electroporation as a factor that alters the cell's susceptibility to forthcoming EPs. Methodology/Principal Findings: We focused first on the role of EP rate for membrane permeabilization and lethal effects in mammalian cells. The rate was varied from 0.001 to 2,000 Hz while keeping other parameters constant (2 to 3,750 pulses of 60-ns to 9-mu s duration, 1.8 to 13.3 kV/cm). The efficiency of all EP treatments was minimal at high rates and started to increase gradually when the rate decreased below a certain value. Although this value ranged widely (0.1-500 Hz), it always corresponded to the overall treatment duration near 10 s. We further found that longer exposures were more efficient irrespective of the EP rate, and that splitting a high-rate EP train in two fractions with 1-5 min delay enhanced the effects severalfold. Conclusions/Significance: For varied experimental conditions, EPs triggered a delayed and gradual sensitization to EPs. When a portion of a multi-pulse exposure was delivered to already sensitized cells, the overall effect markedly increased. Because of the sensitization, the lethality in EP-treated cells could be increased from 0 to 90% simply by increasing the exposure duration, or the exposure dose could be reduced twofold without reducing the effect. Many applications of electroporation can benefit from accounting for sensitization, by organizing the exposure either to maximize sensitization (e.g., for sterilization) or, for other applications, to completely or partially avoid it. In particular, harmful side effects of electroporation-based therapies (electrochemotherapy, gene therapies, tumor ablation) include convulsions, pain, heart fibrillation, and thermal damage. Sensitization can potentially be employed to reduce these side effects while preserving or increasing therapeutic efficiency.
引用
收藏
页数:10
相关论文
共 53 条
[1]   Tumor Ablation with Irreversible Electroporation [J].
Al-Sakere, Bassim ;
Andre, Franck ;
Bernat, Claire ;
Connault, Elisabeth ;
Opolon, Paule ;
Davalos, Rafael V. ;
Rubinsky, Boris ;
Mir, Lluis M. .
PLOS ONE, 2007, 2 (11)
[2]  
André FM, 2008, HUM GENE THER, V19, P1261, DOI 10.1089/hgt.2008.060
[3]  
[Anonymous], 2010, ADV ELECTROPORATION
[4]  
[Anonymous], 2010, ADV ELECTROPORATION
[5]   Irreversible Electroporation: A New Challenge in "Out of Operating Theater" Anesthesia [J].
Ball, Christine ;
Thomson, Kenneth R. ;
Kavnoudias, Helen .
ANESTHESIA AND ANALGESIA, 2010, 110 (05) :1305-1309
[6]   Theoretical modeling of the effects of shock duration, frequency, and strength on the degree of electroporation [J].
Bilska, AO ;
DeBruin, KA ;
Krassowska, W .
BIOELECTROCHEMISTRY, 2000, 51 (02) :133-143
[7]   The generation of reactive-oxygen species associated with long-lasting pulse-induced electropermeabilisation of mammalian cells is based on a non-destructive alteration of the plasma membrane [J].
Bonnafous, P ;
Vernhes, MC ;
Teissié, J ;
Gabriel, B .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1999, 1461 (01) :123-134
[8]   Analysis of Plasma Membrane Integrity by Fluorescent Detection of Tl+ Uptake [J].
Bowman, Angela M. ;
Nesin, Olena M. ;
Pakhomova, Olga N. ;
Pakhomov, Andrei G. .
JOURNAL OF MEMBRANE BIOLOGY, 2010, 236 (01) :15-26
[9]   Inactivation of naturally grown microorganisms in orange juice using pulsed electric fields [J].
El-Hag, Ayman H. ;
Jayaram, Shesha H. ;
Griffiths, Mansel W. .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2006, 34 (04) :1412-1415
[10]   What is (Still not) Known of the Mechanism by Which Electroporation Mediates Gene Transfer and Expression in Cells and Tissues [J].
Escoffre, Jean-Michel ;
Portet, Thomas ;
Wasungu, Luc ;
Teissie, Justin ;
Dean, David ;
Rols, Marie-Pierre .
MOLECULAR BIOTECHNOLOGY, 2009, 41 (03) :286-295