摘要
An amperometric method for the determination of iodide ions has been developed using disposable, screen-printed electrodes. The used sensors have a gold, graphite and platinum working electrodes with an area of about 7 mm(2). Calibration curves exhibit a linear relationship between the electrode response and the iodide concentration up to 3.00 mM. The correlation coefficients for all calibration curves varied from 0.988 to 0.998. The relative standard deviations were equal to or less than 5.26% (n=5). The lowest iodide concentration measured was 100 mu M.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 12 条
[1]  
American Public Health Association, 1998, STANDARD METHODS EXA
[2]   POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF IODIDE AND IODINE [J].
DAVEY, DE ;
MULCAHY, DE ;
OCONNELL, GR .
TALANTA, 1990, 37 (03) :313-316
[3]   SURFACTANT MODIFIED CARBON-PASTE ELECTRODE .2. ANALYTICAL PERFORMANCES [J].
DIGUA, K ;
KAUFFMANN, JM ;
KHODARI, M .
ELECTROANALYSIS, 1994, 6 (5-6) :459-462
[4]  
Khodari M., 2014, ANALYST UNPUB
[5]   Flow injection determination of iodide ion in a photographic developing solution using iodide ion-selective electrode detector [J].
Masadome, T ;
Sonoda, R ;
Asano, Y .
TALANTA, 2000, 52 (06) :1123-1130
[6]   Optimisation of the composition of a screen-printed acrylate polymer enzyme layer with respect to an improved selectivity and stability of enzyme electrodes [J].
Mersal, GAM ;
Khodari, M ;
Bilitewski, U .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (02) :305-314
[7]   STATE OF IODINE IN SEA WATER [J].
SHAW, TI ;
COOPER, LHN .
NATURE, 1957, 180 (4579) :250-250
[8]   Electrochemical characterization of screen-printed carbonaceous electrodes for the determination of peroxidase activity in novel screen-printed flow-through modules [J].
Stiene, M ;
Bilitewski, U .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (02) :240-247
[9]  
SUGAWARA K, 1958, NATURE, V182, P250, DOI 10.1038/182250a0
[10]  
TRUESDALE V W, 1975, Marine Chemistry, V3, P111, DOI 10.1016/0304-4203(75)90018-3