Effective dose conversion coefficients for health care provider exposed to pediatric and adult victims in radiological dispersal device incident

被引:4
作者
Han, Eun Young [1 ]
Ha, Wi-Ho [2 ]
Jin, Young-Woo [2 ]
Bolch, Wesley E. [3 ]
Lee, Choonsik [4 ]
机构
[1] Univ Arkansas Med Sci, Dept Radiat Oncol, Little Rock, AR 72205 USA
[2] Korea Inst Radiol & Med Sci, Natl Radiat Emergency Med Ctr, Seoul, South Korea
[3] Univ Florida, J Crayton Pruitt Family Dept Biomed Engn, Gainesville, FL 32611 USA
[4] NCI, Div Canc Epidemiol & Genet, NIH, Rockville, MD 20850 USA
关键词
radiological dispersal device; effective dose; hybrid phantoms; Monte Carlo calculation; HYBRID COMPUTATIONAL PHANTOMS;
D O I
10.1088/0952-4746/35/1/37
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
After an incident of radiological dispersal devices (RDD), health care providers will be exposed to the contaminated patients in the extended medical treatments. Assessment of potential radiation dose to the health care providers will be crucial to minimize their health risk. In this study, we compiled a set of conversion coefficients (mSv MBq(-1) s(-1)) to readily estimate the effective dose from the time-integrated activity for the health care providers while they deal with internally contaminated patients at different ages. We selected Co-60, Ir-192, Am-241, Cs-137, and I-131 as the major radionuclides that may be used for RDD. We obtained the age-specific organ burdens after the inhalation of those radionuclides from the Dose and Risk Calculation Software (DCAL) program. A series of hybrid computational phantoms (1-, 5-, 10-, and 15 year-old, and adult males) were implemented in a general purpose Monte Carlo (MC) transport code, MCNPX v 2.7, to simulate an adult male health care provider exposed to contaminated patients at different ages. Two exposure scenarios were taken into account: a health care provider (a) standing at the side of patients lying in bed and (b) sitting face to face with patients. The conversion coefficients overall depended on radionuclides, the age of the patients, and the orientation of the patients. The conversion coefficient was greatest for Co-60 and smallest for Am-241. The dose from the 1 year-old patient phantom was up to three times greater than that from the adult patient phantom. The conversion coefficients were less dependent on the age of the patients in the scenario of a health care provider sitting face to face with patients. The dose conversion coefficients established in this study will be useful to readily estimate the effective dose to the health care providers in RDD events.
引用
收藏
页码:37 / 45
页数:9
相关论文
共 19 条
[1]  
[Anonymous], 1994, Ann ICRP, V24, P1
[2]  
[Anonymous], 1995, ANN ICRP, V26, DOI DOI 10.2307/27757755
[3]  
[Anonymous], 2001, 138 NCRP
[4]   GUIDANCE ON THE USE OF HANDHELD SURVEY METERS FOR RADIOLOGICAL TRIAGE: TIME-DEPENDENT DETECTOR COUNT RATES CORRESPONDING TO 50, 250, AND 500 mSV EFFECTIVE DOSE FOR ADULT MALES AND ADULT FEMALES [J].
Bolch, Wesley E. ;
Hurtado, Jorge L. ;
Lee, Choonsik ;
Manger, Ryan ;
Burgett, Eric ;
Hertel, Nolan ;
Dickerson, William .
HEALTH PHYSICS, 2012, 102 (03) :305-325
[5]  
DOE/NRC Interagency Working Group on Radiological Dispersal Devices, 2003, RAD DISP DEV IN STUD
[6]  
Eckerman K., 2008, Annals of the ICRP, V38, P9
[7]  
Eckerman K F, 2006, ORNLTM2001190
[8]   Organ S values and effective doses for family members exposed to adult patients following I-131 treatment: A Monte Carlo simulation study [J].
Han, Eun Young ;
Lee, Choonsik ;
Mcguire, Lynn ;
Brown, Tracy L. Y. ;
Bolch, Wesley E. .
MEDICAL PHYSICS, 2013, 40 (08)
[9]  
ICRU, 1992, 46 ICRU
[10]   Hybrid computational phantoms of the 15-year male and female adolescent: Applications to CT organ dosimetry for patients of variable morphometry [J].
Lee, Choonsik ;
Lodwick, Daniel ;
Williams, Jonathan L. ;
Bolch, Wesley E. .
MEDICAL PHYSICS, 2008, 35 (06) :2366-2382