The dependence of the modulation transfer function on the blocking layer thickness in amorphous selenium x-ray detectors

被引:6
|
作者
Hunter, David M.
Belev, Gueorgi
DeCrescenzo, Giovanni
Kasap, Safa O.
Mainprize, James G.
Rowlands, J. A.
Smith, Charles
Tuemer, Tuemay
Verpakhovski, Vladimir
Yin, Shi
Yaffe, Martin J.
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Saskatchewan, Dept Elect Engn, Saskatoon, SK S7N 5A9, Canada
[3] DALSA Inc, Waterloo, ON N2V 2E9, Canada
[4] NOVA R&D, Riverside, CA 92507 USA
关键词
amorphous selenium; modulation transfer function; CCD; blocking layer; x-ray; digital mammography;
D O I
10.1118/1.2757002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Blocking layers are used to reduce leakage current in amorphous selenium detectors. The effect of the thickness of the blocking layer on the presampling modulation transfer function (MTF) and on dark current was experimentally determined in prototype single-line CCD-based amorphous selenium (a-Se) x-ray detectors. The sampling pitch of the detectors evaluated was 25 mu m and the blocking layer thicknesses varied from 1 to 51 mu m. The blocking layers resided on the signal collection electrodes which, in this configuration, were used to collect electrons. The combined thickness of the blocking layer and a-Se bulk in each detector was similar to 200 mu m. As expected, the dark current increased monotonically as the thickness of the blocking layer was decreased. It was found that if the blocking layer thickness was small compared to the sampling pitch, it caused a negligible reduction in MTF. However, the MTF was observed to decrease dramatically at spatial frequencies near the Nyquist frequency as the blocking layer thickness approached or exceeded the electrode sampling pitch. This observed reduction in MTF is shown to be consistent with predictions of an electrostatic model wherein the image charge from the a-Se is trapped at a characteristic depth within the blocking layer, generally near the interface between the blocking layer and the a-Se bulk. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3358 / 3373
页数:16
相关论文
共 50 条
  • [11] Modeling of dark current and ghosting in multilayer amorphous selenium X-ray detectors
    Kabir, M. Z.
    Manouchehri, F.
    Mahmood, S. A.
    Devabhaktuni, V. K.
    Tousignant, O.
    Mani, H.
    Greenspan, J.
    Botka, P.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [12] Time and exposure dependent x-ray sensitivity in multilayer amorphous selenium detectors
    Manouchehri, F.
    Kabir, M. Z.
    Tousignant, O.
    Mani, H.
    Devabhaktuni, V. K.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2008, 41 (23)
  • [13] Physical properties of amorphous Selenium superlattice structures for future X-ray detectors
    John, Joshua D.
    Miyachi, Noritoshi
    Enomoto, Kunitaka
    Okano, Ken
    Masuzawa, Tomoaki
    Yamada, Takatoshi
    Okano, Shun
    Zahn, Dietrich R. T.
    Chua, Daniel H. C.
    2020 33RD INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2018, : 50 - 51
  • [14] Amorphous silicon X-ray detectors
    Hoheisel, M.
    Arques, M.
    Chabbal, J.
    Chaussat, C.
    Ducourant, T.
    Hahm, G.
    Horbaschek, H.
    Schulz, R.
    Spahn, M.
    Journal of Non-Crystalline Solids, 227-230 (Pt 2): : 1300 - 1305
  • [15] Amorphous silicon X-ray detectors
    Hoheisel, M
    Arques, M
    Chabbal, J
    Chaussat, C
    Ducourant, T
    Hahm, G
    Horbaschek, H
    Schulz, R
    Spahn, M
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1998, 227 : 1300 - 1305
  • [16] Amorphous selenium as an X-ray photoconductor
    Belev, G
    Kasap, SO
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2004, 345 : 484 - 488
  • [17] Modulation transfer function of photoconductive x-ray image detectors: effects of charge carrier trapping
    Kabir, MZ
    Kasap, SO
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (19) : 2352 - 2358
  • [18] A Low-Temperature Processed Organic Hole-Blocking Contact Layer for Amorphous Selenium X-Ray Photoconductor
    Adnani, Sahar
    Pil-Ali, Abdollah
    Karim, Karim S.
    IEEE ELECTRON DEVICE LETTERS, 2023, 44 (09) : 1528 - 1530
  • [19] Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors
    Zhao, W
    DeCrescenzo, G
    Rowlands, JA
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 9 - 20
  • [20] Metallic electrical contacts to stabilized amorphous selenium for use in X-ray image detectors
    Johanson, RE
    Kasap, SO
    Rowlands, J
    Polischuk, B
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1998, 227 : 1359 - 1362