Computational and experimental assessment of solar air heater roughened with six different baffles
被引:51
作者:
Sharma, Sachin
论文数: 0引用数: 0
h-index: 0
机构:
Univ Petr & Energy Studies, Sch Engn, Dept Mech Engn, Dehra Dun 248007, Uttarakhand, IndiaUniv Petr & Energy Studies, Sch Engn, Dept Mech Engn, Dehra Dun 248007, Uttarakhand, India
Sharma, Sachin
[1
]
Das, Randip Kumar
论文数: 0引用数: 0
h-index: 0
机构:
IIT ISM, Dept Mech Engn, Dhanbad, Bihar, IndiaUniv Petr & Energy Studies, Sch Engn, Dept Mech Engn, Dehra Dun 248007, Uttarakhand, India
Das, Randip Kumar
[2
]
Kulkarni, Kishor
论文数: 0引用数: 0
h-index: 0
机构:
Maharashtra Inst Technol MIT, Dept Mech Engn, Aurangabad, Maharashtra, IndiaUniv Petr & Energy Studies, Sch Engn, Dept Mech Engn, Dehra Dun 248007, Uttarakhand, India
Kulkarni, Kishor
[3
]
机构:
[1] Univ Petr & Energy Studies, Sch Engn, Dept Mech Engn, Dehra Dun 248007, Uttarakhand, India
[2] IIT ISM, Dept Mech Engn, Dhanbad, Bihar, India
Baffles;
CFD;
Local Nusselt number and friction factor;
Thermo-hydraulic performance;
FRICTION FACTOR CORRELATIONS;
BROKEN TRANSVERSE RIBS;
TRANSFER ENHANCEMENT;
ABSORBER PLATE;
THERMOHYDRAULIC PERFORMANCE;
RECTANGULAR DUCT;
TRANSFER AUGMENTATION;
FLOW CHARACTERISTICS;
THERMAL PERFORMANCE;
NUSSELT NUMBER;
D O I:
10.1016/j.csite.2021.101350
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
The present study emphasizes on a comparative assessment of solar air heater (SAH) roughened with six different baffles viz. Transverse, inclined transverse, dimple, inclined dimple, arc and sine wave, using computational fluid dynamics (CFD) analysis. The comparison has performed to investigate the augmentation in the heat transfer and friction factor of SAH with different baffles. The CFD study has been accomplished by varying Reynolds number (Re) from 3000 to 18000 whereas, Relative roughness pitch (P/e=10) and Relative roughness height (e/D-h= 0.271) were kept fixed. Flow patterns by varying (Re), local and average Nusselt number, local and average friction factor, thermo-hydraulic performance (THP) have reported and elaborated. The computational results have verified by performing experiments on the same set of operating and geometric parameters. The deviation among numerical and experimental results of THP have found +11%, which are in acceptable range. The results reveals that the positioning and shape of baffle unswervingly affect the THP of the solar air heater. The maximum THP of 2.05 has been recorded with a sine wave shape baffles at Re = 15000. The sine wave baffle shape has judged as the best among the studied baffles on a given range of operating and geometric parameters.
机构:
Mustansiriyah Univ, Fac Engn, Dept Mech Engn, Baghdad, IraqMustansiriyah Univ, Fac Engn, Dept Mech Engn, Baghdad, Iraq
Al-Obaidi, Ahmed Ramadhan
Chaer, Issa
论文数: 0引用数: 0
h-index: 0
机构:
London South Bank Univ, Sch Built Environm & Architecture, Res & Enterprise, London, EnglandMustansiriyah Univ, Fac Engn, Dept Mech Engn, Baghdad, Iraq
机构:
Uttarakhand Tech Univ, Fac Technol, Dept Thermal Engn, Dehra Dun, Uttarakhand, IndiaUttarakhand Tech Univ, Fac Technol, Dept Thermal Engn, Dehra Dun, Uttarakhand, India
Bahuguna, Rahul
Mer, K. K. S.
论文数: 0引用数: 0
h-index: 0
机构:
GBPIET, Dept Mech Engn, Pauri Garhwal, Uttarakhand, IndiaUttarakhand Tech Univ, Fac Technol, Dept Thermal Engn, Dehra Dun, Uttarakhand, India
Mer, K. K. S.
Kumar, Manoj
论文数: 0引用数: 0
h-index: 0
机构:
DIT Univ, Dept Mech Engn, Dehra Dun, Uttarakhand, IndiaUttarakhand Tech Univ, Fac Technol, Dept Thermal Engn, Dehra Dun, Uttarakhand, India
Kumar, Manoj
Chamoli, Sunil
论文数: 0引用数: 0
h-index: 0
机构:
GBPIET, Dept Mech Engn, Pauri Garhwal, Uttarakhand, IndiaUttarakhand Tech Univ, Fac Technol, Dept Thermal Engn, Dehra Dun, Uttarakhand, India
机构:
Mustansiriyah Univ, Fac Engn, Dept Mech Engn, Baghdad, IraqMustansiriyah Univ, Fac Engn, Dept Mech Engn, Baghdad, Iraq
Al-Obaidi, Ahmed Ramadhan
Chaer, Issa
论文数: 0引用数: 0
h-index: 0
机构:
London South Bank Univ, Sch Built Environm & Architecture, Res & Enterprise, London, EnglandMustansiriyah Univ, Fac Engn, Dept Mech Engn, Baghdad, Iraq
机构:
Uttarakhand Tech Univ, Fac Technol, Dept Thermal Engn, Dehra Dun, Uttarakhand, IndiaUttarakhand Tech Univ, Fac Technol, Dept Thermal Engn, Dehra Dun, Uttarakhand, India
Bahuguna, Rahul
Mer, K. K. S.
论文数: 0引用数: 0
h-index: 0
机构:
GBPIET, Dept Mech Engn, Pauri Garhwal, Uttarakhand, IndiaUttarakhand Tech Univ, Fac Technol, Dept Thermal Engn, Dehra Dun, Uttarakhand, India
Mer, K. K. S.
Kumar, Manoj
论文数: 0引用数: 0
h-index: 0
机构:
DIT Univ, Dept Mech Engn, Dehra Dun, Uttarakhand, IndiaUttarakhand Tech Univ, Fac Technol, Dept Thermal Engn, Dehra Dun, Uttarakhand, India
Kumar, Manoj
Chamoli, Sunil
论文数: 0引用数: 0
h-index: 0
机构:
GBPIET, Dept Mech Engn, Pauri Garhwal, Uttarakhand, IndiaUttarakhand Tech Univ, Fac Technol, Dept Thermal Engn, Dehra Dun, Uttarakhand, India