Continuous measurement of radon exhalation rate of soil in Beijing

被引:12
|
作者
Zhang, Lei [1 ,2 ]
Guo, Qiuju [1 ]
Sun, Ke [1 ]
机构
[1] Peking Univ, State Key Lab Nucl Phys & Technol, Sch Phys, Beijing 102205, Peoples R China
[2] Solid Dosimetr Detector & Method Lab, Beijing 102205, Peoples R China
基金
中国国家自然科学基金;
关键词
Radon exhalation rate; Continuous measurement; Soil; Precipitation;
D O I
10.1007/s10967-014-3783-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To understand the level of radon exhalation rate from soil surface and its variation, a continuous measurement system was developed and applied for a field measurement in Beijing from April 2012 to February 2013. For seasonal variation, It was indicated by measurement results that radon exhalation rate was higher in spring (52.9 mBq m(-2) s(-1) in average) and lower in winter (17.0 mBq m(-2) s(-1) in average). The precipitation had a strong influence on the radon exhalation rate, usually radon exhalation rate increased quickly after rain. Daily variation of radon exhalation rate was also observed in spring, usually higher at noon and lower at midnight.
引用
收藏
页码:1623 / 1627
页数:5
相关论文
共 50 条
  • [1] Continuous measurement of radon exhalation rate of soil in Beijing
    Lei Zhang
    Qiuju Guo
    Ke Sun
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 303 : 1623 - 1627
  • [2] Development and application of a continuous measurement system for radon exhalation rate
    Hosoda, Masahiro
    Ishikawa, Tetsuo
    Sorimachi, Atsuyuki
    Tokonami, Shinji
    Uchida, Shigeo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (01):
  • [3] SOIL RADON EXHALATION RATE MEASUREMENT IN DUHOK CITY BY TWO TECHNIQUES
    Alhamdi, Walat A. H.
    Abdullah, Khairi M-S
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2022, 37 (03): : 229 - 234
  • [4] Measurement of radon exhalation rate in various building materials and soil samples
    Bala, Pankaj
    Kumar, Vinod
    Mehra, Rohit
    JOURNAL OF EARTH SYSTEM SCIENCE, 2017, 126 (02)
  • [5] Measurement of radon exhalation rate in various building materials and soil samples
    Pankaj Bala
    Vinod Kumar
    Rohit Mehra
    Journal of Earth System Science, 2017, 126
  • [6] Measurement of radon exhalation rate and soil gas radon concentration in areas of southern Punjab, Pakistan
    Mujahid, S. A.
    Hussain, S.
    Ramzan, M.
    RADIATION PROTECTION DOSIMETRY, 2010, 140 (03) : 300 - 303
  • [7] Measurement of Radium Concentration and Radon Exhalation Rate in Soil Samples Using SSNTDs
    Baruah, D. M. B.
    Deka, P. C.
    Rahman, M.
    AFRICAN REVIEW OF PHYSICS, 2013, 8 : 215 - 218
  • [8] Measurement of radon exhalation rate from soil samples of Garhwal Himalaya, India
    Ramola, RC
    Choubey, VM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 256 (02) : 219 - 223
  • [9] Measurement of radon exhalation rate from soil samples of Garhwal Himalaya, India
    R. C. Ramola
    V. M Choubey
    Journal of Radioanalytical and Nuclear Chemistry, 2003, 256 : 219 - 223
  • [10] Simultaneous measurement of radon and thoron exhalation rate from soil and building materials
    Cosma, C
    Cozar, O
    Jurcut, T
    Baciu, C
    Pop, I
    NATURAL RADIATION ENVIRONMENT VII, 2005, 7 : 699 - 705