A 1.5 kW Radio-Frequency Tunable Matching Network Based on Phase-Switched Impedance Modulation

被引:27
作者
Al Bastami, Anas [1 ]
Jurkov, Alexander [2 ]
Otten, David [1 ]
Nguyen, Duy T. [2 ]
Radomski, Aaron [2 ]
Perreault, David J. [1 ]
机构
[1] MIT, Dept Elect & Comp Sci, Cambridge, MA 02139 USA
[2] MKS Instruments Inc, Rochester, NY 14623 USA
来源
IEEE OPEN JOURNAL OF POWER ELECTRONICS | 2020年 / 1卷
关键词
Impedance matching; impedance transformation; impedance modulation; plasma generation; phase-switched impedance; PSIM; tunable matching network; antenna tuning unit; capacitively-coupled plasma; POWER; DESIGN; SYSTEM;
D O I
10.1109/OJPEL.2020.2987782
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dynamically-tunable impedance matching is a key feature in numerous radio-frequency (RF) applications at high frequencies (10 s of MHz) and power levels (100s-1000 s of Watts and above). This work develops techniques that enable the design of high power tunable matching networks (TMN) that can be tuned orders of magnitude faster than with conventional tunable impedance matching techniques, while realizing the high power levels required for many industrial applications. This is achieved by leveraging an emerging technique - known as phase-switched impedance modulation (PSIM), which involves switching passive elements at the rf operating frequency - that has previously been demonstrated at rf frequencies at up to a few hundred Watts. In this paper, we develop design approaches that enable it to be practically used at up to many kilowatts of power at frequencies in the 10 s of MHz. A detailed analysis of the factors affecting the losses as well as the tradeoffs of a basic PSIM-based element is provided. Furthermore, it is shown how incorporating additional stages to the PSIM-based element, including impedance scaling and/or the addition of series or shunt passive elements, influences the losses and enables the efficient processing of high power levels given the limitations of available switches. A PSIM-based TMN that matches load impedances to 50 and delivers up to 1.5 kW of power at frequencies centered around 13.56 MHz is implemented and tested over a load impedance range suitable for various industrial plasma processes.
引用
收藏
页码:124 / 138
页数:15
相关论文
共 39 条
  • [1] Abuelhaija A, 2015, 2015 GERMAN MICROWAVE CONFERENCE, P119, DOI 10.1109/GEMIC.2015.7107767
  • [2] Dynamic Matching System for Radio-Frequency Plasma Generation
    Al Bastami, Anas
    Jurkov, Alexander
    Gould, Parker
    Hsing, Mitchell
    Schmidt, Martin
    Ha, Jung-Ik
    Perreault, David J.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (03) : 1940 - 1951
  • [3] [Anonymous], 2016, P IEEE 17 WORKSH CON
  • [4] [Anonymous], 2001, QEX
  • [5] A High-Frequency Inverter for Variable-Load Operation
    Braun, Weston D.
    Perreault, David J.
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2019, 7 (02) : 706 - 721
  • [6] Chung E, 2019, IEEE ENER CONV, P2178, DOI [10.1109/ECCE.2019.8912491, 10.1109/ecce.2019.8912491]
  • [7] Davis W.Alan., 2001, WILEY MICRO
  • [8] High-Power Transmission Line Transformer Design for Plasma Generators
    Eroglu, Abdullah
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (04) : 969 - 975
  • [9] Improving Power Amplifier Efficiency and Linearity Using a Dynamically Controlled Tunable Matching Network
    Fu, Jia-Shiang
    Mortazawi, Amir
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (12) : 3239 - 3244
  • [10] Galapon B.J., 2018, 2018 IEEE 19 WORKSHO, P1, DOI 10.1109/COMPEL.2018.8460051