Quantitative Analysis of Pharmaceutical Bilayer Tablets Using Transmission Raman Spectroscopy

被引:15
作者
Zhang, Yan [1 ]
McGeorge, Gary [1 ]
机构
[1] Bristol Myers Squibb Co, Analyt & Bioanalyt Dev, New Brunswick, NJ 08901 USA
关键词
Bilayer; Tablets; Transmission; Raman; Schrader; Kubelka-Munk; Diffusion; SIGNAL; SENSITIVITY; DEPENDENCE; SCATTERING;
D O I
10.1007/s12247-015-9223-8
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction Transmission Raman Spectroscopy (TRS) has become an increasingly applied technology in the analysis of pharmaceutical tablets for quality control purposes and developing formulation and process understanding. One area that has received only cursory attention to date is that of bilayered tablets that represents an unusually challenging situation. This study aims to provide an understanding of the relationship of the active pharmaceutical ingredient (API) content and the transmission Raman spectral response in bilayered pharmaceutical tablets to facilitate development of quantitative models for the prediction of API content in multilayer tablets. Methods and Results The Raman intensity was considered as a function of the Raman photon generation and decay in a layer of interest (the API layer) and Raman photon decay from a second layer (the non-API layer). To separate and understand the various contributions, a variety of tablet configurations were studied and it was found that (1) with increasing the thickness of the non-API layer, the API Raman signal displayed an exponential decay as a function of the non-API layer thickness as well as the total tablet thickness; (2) when only changing API concentration, the Raman signal linearly responds to the API content; and (3) when increasing the weight/thickness of the API layer and keeping the non-API layer constant, the Raman signal reaches a maximum at a particular thickness and then decays as tablets become thicker. The complex spectral response was effectively modeled according to a modified Schrader, Kubelka-Munk model where both the Raman photon generation factor and photon losses were accounted for. Coupling the results of these studies together yields a comprehensive approach for modeling multi-component bilayer tablets. The addition of a beam enhancer on the bottom surface allowed for a selective overenhancement of the bottom layer, which helps in the analysis of thin layers or coatings.
引用
收藏
页码:269 / 280
页数:12
相关论文
共 50 条
  • [21] Analytical Method Development Using Transmission Raman Spectroscopy for Pharmaceutical Assays and Compliance with Regulatory Guidelines-Part I: Transmission Raman Spectroscopy and Method Development
    Andrews, Darren
    Geentjens, Kris
    Igne, Benoit
    McGeorge, Gary
    Owen, Andrew
    Pedge, Nicholas
    Villaumie, Julien
    Woodward, Vicki
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2018, 13 (02) : 121 - 132
  • [22] Assessment and prediction of tablet properties using transmission and backscattering Raman spectroscopy and transmission NIR spectroscopy
    Peeters, Elisabeth
    Tavares da Silva, Ana Filipa
    Toiviainen, Maunu
    Van Renterghem, Jeroen
    Vercruysse, Jurgen
    Juuti, Mikko
    Lopes, Joao Almeida
    De Beer, Thomas
    Vervaet, Chris
    Remon, Jean-Paul
    ASIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2016, 11 (04) : 547 - 558
  • [23] Quantitative analysis of anatase in Georgia kaolins using Raman spectroscopy
    Schroeder, PA
    Melear, ND
    Pruett, RJ
    APPLIED CLAY SCIENCE, 2003, 23 (5-6) : 299 - 308
  • [24] Transmission Raman spectroscopy as a tool for quantifying polymorphic content of pharmaceutical formulations
    Aina, Adeyinka
    Hargreaves, Michael D.
    Matousek, Pavel
    Burley, Jonathan C.
    ANALYST, 2010, 135 (09) : 2328 - 2333
  • [25] Surface enhanced transmission Raman spectroscopy: Quantitative performances for impurity analysis in complex matrices
    Horne, Julie
    Beckers, Pierre
    Sacre, Pierre-Yves
    Francotte, Pierre
    Caudron, Eric
    Hubert, Philippe
    De Bleye, Charlotte
    Ziemons, Eric
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 252
  • [26] Influence of moisture variation on the performance of Raman spectroscopy in quantitative pharmaceutical analyses
    Hossain, Md Nayeem
    Igne, Benoit
    Anderson, Carl A.
    Drennen, James K., III
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 164 : 528 - 535
  • [27] An in-depth analysis of Raman and near-infrared chemical images of common pharmaceutical tablets
    Sasic, Slobodan
    APPLIED SPECTROSCOPY, 2007, 61 (03) : 239 - 250
  • [28] Analysis of the dehydration process of caffeine using backscattering and transmission Raman spectroscopy
    Takeshima, Rina
    Hattori, Yusuke
    Managaki, Satoshi
    Otsuka, Makoto
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2017, 530 (1-2) : 256 - 262
  • [29] A Rapid and Sensitive Quantitative Analysis Method for TNT using Raman Spectroscopy
    Gao, Feng
    Liu, Wenfang
    Meng, Zihui
    Su, Pengfei
    Li, Zhixue
    Wang, Minghui
    PROPELLANTS EXPLOSIVES PYROTECHNICS, 2019, 44 (03) : 337 - 344
  • [30] Recent advancements and applications of Raman spectroscopy in pharmaceutical analysis
    Shah, Kashvi C.
    Shah, Maitri B.
    Solanki, Sakshi J.
    Makwana, Vikas D.
    Sureja, Dipen K.
    Gajjar, Anuradha K.
    Bodiwala, Kunjan B.
    Dhameliya, Tejas M.
    JOURNAL OF MOLECULAR STRUCTURE, 2023, 1278