Surface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging

被引:38
作者
Lightheart, Kurtis G. [1 ]
English, Jeryl D. [1 ]
Kau, Chung H. [2 ]
Akyalcin, Sercan [1 ]
Bussa, Harry I., Jr. [1 ]
McGrory, Kathleen R. [1 ]
McGrory, Kevin J. [1 ]
机构
[1] Univ Texas Houston, Hlth Sci Ctr, Sch Dent, Dept Orthodont, Houston, TX 77030 USA
[2] Univ Alabama Birmingham, Sch Dent, Dept Orthodont, Birmingham, AL USA
关键词
DIGITAL MODELS; PLASTER MODELS; SPACE ANALYSIS; ACCURACY; RELIABILITY; INDEX; VALIDITY; TOOTH;
D O I
10.1016/j.ajodo.2011.12.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this research was to determine the accuracy of digital models generated by cone-beam computed tomography and compare it with that of OrthoCAD models (Cadent, Carlstadt, NJ) for orthodontic diagnosis and treatment planning by using surface area analysis. Materials: Two sets of maxillary and mandibular digital models of 30 subjects were obtained. The models were made from impressions scanned with OrthoCAD and by conversion of related cone-beam computed tomography files. Each patient's matched pairs of maxillary and mandibular models were superimposed by using a software program and a best-fit algorithm; surface-to-surface analysis was then performed. The average linear differences between the 2 files at all points on the surfaces were measured, and tolerance levels of 0.25, 0.5, 0.75, 1.0, 1.25, and 1.5 mm were set to determine the surface correlation amounts between the 2 files. Additionally, 6 linear measurements from predetermined landmarks were also measured and analyzed. Results: The average maxillary model linear difference was 0.28 to 0.60 mm, whereas the average mandibular model linear difference ranged between 0.34 and 0.61 mm. Greater than a 90% surface correlation was obtained on average at 1.00 mm in the maxillary models and at 1.25 mm in the mandibular models. The mean differences obtained from the linear measurements of the maxillary and mandibular models were 0.071 and 0.018 mm, respectively. Conclusions: Surface-to-surface analysis of OrthoCAD and digital models generated by cone-beam computed tomography pointed to a fair overlap between the protocols. The accuracy of digital models generated by cone-beam computed tomography is adequate for initial diagnosis and treatment planning in orthodontics. (Am J Orthod Dentofacial Orthop 2012;141:686-93)
引用
收藏
页码:686 / 693
页数:8
相关论文
共 50 条
[21]   Cone-beam computed tomography is the imaging technique of choice for comprehensive orthodontic assessment [J].
Larson, Brent E. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 141 (04) :402-406
[22]   Accuracy Assessment of Three-dimensional Surface Reconstructions of In vivo Teeth from Cone-beam Computed Tomography [J].
Sang, Yan-Hui ;
Hu, Hong-Cheng ;
Lu, Song-He ;
Wu, Yu-Wei ;
Li, Wei-Ran ;
Tang, Zhi-Hui .
CHINESE MEDICAL JOURNAL, 2016, 129 (12) :1464-1470
[23]   Accuracy Assessment of Three-dimensional Surface Reconstructions of In vivo Teeth from Cone-beam Computed Tomography [J].
Sang YanHui ;
Hu HongCheng ;
Lu SongHe ;
Wu YuWei ;
Li WeiRan ;
Tang ZhiHui .
中华医学杂志英文版, 2016, 129 (12) :1464-1470
[24]   Reliability assessment of craniofacial and airway measurements: a comparative study between multidetector computed tomography and cone-beam computed tomography [J].
Sun, Jui-Sheng ;
Hung, Min-Chih ;
Hsieh, Chi-Yeh ;
Lin, Shih-Ying ;
Tai, Han-Cheng ;
Chang, Jenny Zwei-Chieng .
ANGLE ORTHODONTIST, 2025, 95 (01) :57-77
[25]   Evaluation of WALA ridge in different facial patterns: A cone-beam computed tomography study [J].
Tonial, Fernanda Guzzo ;
Ferreira, Marcos Cezar ;
Araki, Janine ;
Ferreira, Vinicius de Mello ;
Silva Lima, Marcelo da Luz ;
Guimaraes Jr, Carlos Henrique .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 161 (06) :E580-E587
[26]   Movement of mandibular molar into edentulous alveolar ridge: A cone-beam computed tomography study [J].
Dutra dos Santos, Patricia Bittencourt ;
Herrera Sanches, Francyle Simoes ;
Ferreira, Marcos Cezar ;
Pompeia Fraga de Almeida, Ana Lucia ;
Janson, Guilherme ;
Garib, Daniela .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 151 (05) :907-913
[27]   Practical applications of cone-beam computed tomography in orthodontics [J].
Mah, James K. ;
Huang, John C. ;
Choo, HyeRan .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10) :7S-13S
[28]   Quality Control in Dental Cone-Beam Computed Tomography [J].
Huang, Jin-Feng ;
Chen, Xiao-Zhao ;
Wang, Hong .
APPLIED SCIENCES-BASEL, 2021, 11 (17)
[29]   Osteoporosis detection using cone-beam computed tomography [J].
Geibel, M-A. ;
Loeffler, F. ;
Kildal, D. .
ORTHOPADE, 2016, 45 (12) :1066-1071
[30]   Automatic landmark identification in cone-beam computed tomography [J].
Gillot, Maxime ;
Miranda, Felicia ;
Baquero, Baptiste ;
Ruellas, Antonio ;
Gurgel, Marcela ;
Al Turkestani, Najla ;
Anchling, Luc ;
Hutin, Nathan ;
Biggs, Elizabeth ;
Yatabe, Marilia ;
Paniagua, Beatriz ;
Fillion-Robin, Jean-Christophe ;
Allemang, David ;
Bianchi, Jonas ;
Cevidanes, Lucia ;
Prieto, Juan Carlos .
ORTHODONTICS & CRANIOFACIAL RESEARCH, 2023, 26 (04) :560-567