Introduction: The purpose of this research was to determine the accuracy of digital models generated by cone-beam computed tomography and compare it with that of OrthoCAD models (Cadent, Carlstadt, NJ) for orthodontic diagnosis and treatment planning by using surface area analysis. Materials: Two sets of maxillary and mandibular digital models of 30 subjects were obtained. The models were made from impressions scanned with OrthoCAD and by conversion of related cone-beam computed tomography files. Each patient's matched pairs of maxillary and mandibular models were superimposed by using a software program and a best-fit algorithm; surface-to-surface analysis was then performed. The average linear differences between the 2 files at all points on the surfaces were measured, and tolerance levels of 0.25, 0.5, 0.75, 1.0, 1.25, and 1.5 mm were set to determine the surface correlation amounts between the 2 files. Additionally, 6 linear measurements from predetermined landmarks were also measured and analyzed. Results: The average maxillary model linear difference was 0.28 to 0.60 mm, whereas the average mandibular model linear difference ranged between 0.34 and 0.61 mm. Greater than a 90% surface correlation was obtained on average at 1.00 mm in the maxillary models and at 1.25 mm in the mandibular models. The mean differences obtained from the linear measurements of the maxillary and mandibular models were 0.071 and 0.018 mm, respectively. Conclusions: Surface-to-surface analysis of OrthoCAD and digital models generated by cone-beam computed tomography pointed to a fair overlap between the protocols. The accuracy of digital models generated by cone-beam computed tomography is adequate for initial diagnosis and treatment planning in orthodontics. (Am J Orthod Dentofacial Orthop 2012;141:686-93)
引用
收藏
页码:686 / 693
页数:8
相关论文
共 50 条
[1]   Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography [J].
Kim, Jooseong ;
Heo, Giseon ;
Lagravere, Manuel O. .
ANGLE ORTHODONTIST, 2014, 84 (03) :443-450
[2]   The validity, reliability, and time requirement of study model analysis using cone-beam computed tomography-generated virtual study models [J].
Luu, N. S. ;
Mandich, M-A. ;
Flores-Mir, C. ;
El-Bialy, T. ;
Heo, G. ;
Carey, J. P. ;
Major, P. W. .
ORTHODONTICS & CRANIOFACIAL RESEARCH, 2014, 17 (01) :14-26
[3]   Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions [J].
Jiang, Tingting ;
Lee, Sang-Mi ;
Hou, Yanan ;
Chang, Xin ;
Hwang, Hyeon-Shik .
KOREAN JOURNAL OF ORTHODONTICS, 2016, 46 (03) :129-136
[4]   Accuracy of three-dimensional printed models derived from cone-beam computed tomography [J].
Ferraro, Joshua M. ;
Falter, Jacob ;
Lee, Sanghee ;
Watanabe, Keiichiro ;
Wu, Tai-Hsien ;
Kim, Do-Gyoon ;
Ko, Ching-Chang ;
Tanaka, Eiji ;
Deguchi, Toru .
ANGLE ORTHODONTIST, 2022, 92 (06) :722-727
[5]   Comparison of linear and angular changes assessed in digital dental models and cone-beam computed tomography [J].
Massaro, Camila ;
Losada, Carolina ;
Cevidanes, Lucia ;
Yatabe, Marilia ;
Garib, Daniela ;
Pereira Lauris, Jose Roberto ;
Ioshida, Marcos ;
Rey, Diego ;
Antonia Alvarez, Maria ;
Benavides, Erika ;
Rios, Hector ;
Fernando Aristizabal, Juan ;
Ruellas, Antonio Carlos .
ORTHODONTICS & CRANIOFACIAL RESEARCH, 2020, 23 (01) :118-128
[6]   Cone-Beam Computed Tomography for Temporomandibular Joint Imaging [J].
Dhabale, Gunjan S. ;
Bhowate, Rahul R. .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
[7]   Reliability of cone-beam computed tomography for temporomandibular joint analysis [J].
Gorucu-Coskuner, Hande ;
Atik, Ezgi ;
El, Hakan .
KOREAN JOURNAL OF ORTHODONTICS, 2019, 49 (02) :81-88
[8]   The reliability of cone-beam computed tomography (CBCT) - Generated frontal cephalogramsq [J].
Kim, So-Jin ;
Park, Soo-Byung ;
Kim, Yong-Il ;
Cho, Bong-Hae ;
Hwang, Dae-Seok .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (08) :E331-E336
[9]   Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts [J].
de Waard, Olivier ;
Rangel, Frits Andreas ;
Fudalej, Piotr Stanislaw ;
Bronkhorst, Ewald Maria ;
Kuijpers-Jagtman, Anne Marie ;
Breuning, Karel Hero .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 146 (03) :328-336
[10]   Cone-beam computed tomography is not the imaging technique of choice for comprehensive orthodontic assessment [J].
Halazonetis, Demetrios J. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 141 (04) :407-411