Surface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging

被引:38
|
作者
Lightheart, Kurtis G. [1 ]
English, Jeryl D. [1 ]
Kau, Chung H. [2 ]
Akyalcin, Sercan [1 ]
Bussa, Harry I., Jr. [1 ]
McGrory, Kathleen R. [1 ]
McGrory, Kevin J. [1 ]
机构
[1] Univ Texas Houston, Hlth Sci Ctr, Sch Dent, Dept Orthodont, Houston, TX 77030 USA
[2] Univ Alabama Birmingham, Sch Dent, Dept Orthodont, Birmingham, AL USA
关键词
DIGITAL MODELS; PLASTER MODELS; SPACE ANALYSIS; ACCURACY; RELIABILITY; INDEX; VALIDITY; TOOTH;
D O I
10.1016/j.ajodo.2011.12.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this research was to determine the accuracy of digital models generated by cone-beam computed tomography and compare it with that of OrthoCAD models (Cadent, Carlstadt, NJ) for orthodontic diagnosis and treatment planning by using surface area analysis. Materials: Two sets of maxillary and mandibular digital models of 30 subjects were obtained. The models were made from impressions scanned with OrthoCAD and by conversion of related cone-beam computed tomography files. Each patient's matched pairs of maxillary and mandibular models were superimposed by using a software program and a best-fit algorithm; surface-to-surface analysis was then performed. The average linear differences between the 2 files at all points on the surfaces were measured, and tolerance levels of 0.25, 0.5, 0.75, 1.0, 1.25, and 1.5 mm were set to determine the surface correlation amounts between the 2 files. Additionally, 6 linear measurements from predetermined landmarks were also measured and analyzed. Results: The average maxillary model linear difference was 0.28 to 0.60 mm, whereas the average mandibular model linear difference ranged between 0.34 and 0.61 mm. Greater than a 90% surface correlation was obtained on average at 1.00 mm in the maxillary models and at 1.25 mm in the mandibular models. The mean differences obtained from the linear measurements of the maxillary and mandibular models were 0.071 and 0.018 mm, respectively. Conclusions: Surface-to-surface analysis of OrthoCAD and digital models generated by cone-beam computed tomography pointed to a fair overlap between the protocols. The accuracy of digital models generated by cone-beam computed tomography is adequate for initial diagnosis and treatment planning in orthodontics. (Am J Orthod Dentofacial Orthop 2012;141:686-93)
引用
收藏
页码:686 / 693
页数:8
相关论文
共 50 条
  • [1] Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography
    Kim, Jooseong
    Heo, Giseon
    Lagravere, Manuel O.
    ANGLE ORTHODONTIST, 2014, 84 (03) : 443 - 450
  • [2] The validity, reliability, and time requirement of study model analysis using cone-beam computed tomography-generated virtual study models
    Luu, N. S.
    Mandich, M-A.
    Flores-Mir, C.
    El-Bialy, T.
    Heo, G.
    Carey, J. P.
    Major, P. W.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2014, 17 (01) : 14 - 26
  • [3] Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions
    Jiang, Tingting
    Lee, Sang-Mi
    Hou, Yanan
    Chang, Xin
    Hwang, Hyeon-Shik
    KOREAN JOURNAL OF ORTHODONTICS, 2016, 46 (03) : 129 - 136
  • [4] Accuracy of three-dimensional printed models derived from cone-beam computed tomography
    Ferraro, Joshua M.
    Falter, Jacob
    Lee, Sanghee
    Watanabe, Keiichiro
    Wu, Tai-Hsien
    Kim, Do-Gyoon
    Ko, Ching-Chang
    Tanaka, Eiji
    Deguchi, Toru
    ANGLE ORTHODONTIST, 2022, 92 (06) : 722 - 727
  • [5] Comparison of linear and angular changes assessed in digital dental models and cone-beam computed tomography
    Massaro, Camila
    Losada, Carolina
    Cevidanes, Lucia
    Yatabe, Marilia
    Garib, Daniela
    Pereira Lauris, Jose Roberto
    Ioshida, Marcos
    Rey, Diego
    Antonia Alvarez, Maria
    Benavides, Erika
    Rios, Hector
    Fernando Aristizabal, Juan
    Ruellas, Antonio Carlos
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2020, 23 (01) : 118 - 128
  • [6] Cone-Beam Computed Tomography for Temporomandibular Joint Imaging
    Dhabale, Gunjan S.
    Bhowate, Rahul R.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [7] Reliability of cone-beam computed tomography for temporomandibular joint analysis
    Gorucu-Coskuner, Hande
    Atik, Ezgi
    El, Hakan
    KOREAN JOURNAL OF ORTHODONTICS, 2019, 49 (02) : 81 - 88
  • [8] The reliability of cone-beam computed tomography (CBCT) - Generated frontal cephalogramsq
    Kim, So-Jin
    Park, Soo-Byung
    Kim, Yong-Il
    Cho, Bong-Hae
    Hwang, Dae-Seok
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (08) : E331 - E336
  • [9] Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts
    de Waard, Olivier
    Rangel, Frits Andreas
    Fudalej, Piotr Stanislaw
    Bronkhorst, Ewald Maria
    Kuijpers-Jagtman, Anne Marie
    Breuning, Karel Hero
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 146 (03) : 328 - 336
  • [10] Cone-beam computed tomography is not the imaging technique of choice for comprehensive orthodontic assessment
    Halazonetis, Demetrios J.