Trace analysis of environmental matrices by large-volume injection and liquid chromatography-mass spectrometry

被引:58
作者
Busetti, Francesco [2 ]
Backe, Will J. [3 ]
Bendixen, Nina [4 ]
Maier, Urs [4 ]
Place, Benjamin [3 ]
Giger, Walter [5 ]
Field, Jennifer A. [1 ]
机构
[1] Oregon State Univ, Dept Environm & Mol Toxicol, Corvallis, OR 97331 USA
[2] Curtin Univ Technol, Curtin Water Qual Res Ctr, Dept Chem, Perth, WA 6102, Australia
[3] Oregon State Univ, Dept Chem, Corvallis, OR 97331 USA
[4] Bachema Analyt Labs, CH-8952 Schlieren, Switzerland
[5] Giger Res Consulting, GRC, CH-8049 Zurich, Switzerland
关键词
Large-volume injection; Direct injection; Liquid chromatography; LC-MS-MS; Soil; Solid-phase extraction; Sample preparation; Water; Wastewater; SOLID-PHASE EXTRACTION; FLOW-THROUGH EXTRACTION; RAY CONTRAST-MEDIA; WATER SAMPLES; WASTE-WATER; QUANTITATIVE-DETERMINATION; LEVEL DETERMINATION; POLAR PESTICIDES; LC-MS/MS; DETECTION SENSITIVITY;
D O I
10.1007/s00216-011-5290-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The time-honored convention of concentrating aqueous samples by solid-phase extraction (SPE) is being challenged by the increasingly widespread use of large-volume injection (LVI) liquid chromatography-mass spectrometry (LC-MS) for the determination of traces of polar organic contaminants in environmental samples. Although different LVI approaches have been proposed over the last 40 years, the simplest and most popular way of performing LVI is known as single-column LVI (SC-LVI), in which a large-volume of an aqueous sample is directly injected into an analytical column. For the purposes of this critical review, LVI is defined as an injected sample volume that is a parts per thousand yen10% of the void volume of the analytical column. Compared with other techniques, SC-LVI is easier to set up, because it requires only small hardware modifications to existing autosamplers and, thus, it will be the main focus of this review. Although not new, SC-LVI is gaining acceptance and the approach is emerging as a technique that will render SPE nearly obsolete for many environmental applications. In this review, we discuss: the history and development of various forms of LVI; the critical factors that must be considered when creating and optimizing SC-LVI methods; and typical applications that demonstrate the range of environmental matrices to which LVI is applicable, for example drinking water, groundwater, and surface water including seawater and wastewater. Furthermore, we indicate direction and areas that must be addressed to fully delineate the limits of SC-LVI.
引用
收藏
页码:175 / 186
页数:12
相关论文
共 68 条
[1]   DETERMINATION OF BENZENESULFONATES AND NAPHTHALENESULFONATES IN WASTE-WATER BY SOLID-PHASE EXTRACTION WITH GRAPHITIZED CARBON-BLACK AND ION-PAIR LIQUID-CHROMATOGRAPHY WITH UV DETECTION [J].
ALTENBACH, B ;
GIGER, W .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2325-2333
[2]   Determination of alkylbenzene metabolites in groundwater by solid-phase extraction and liquid chromatography-tandem mass spectrometry [J].
Alumbaugh, RE ;
Gieg, LM ;
Field, JA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1042 (1-2) :89-97
[3]   Analysis of Androgenic Steroids in Environmental Waters by Large-Volume Injection Liquid Chromatography Tandem Mass Spectrometry [J].
Backe, Will J. ;
Ort, Christoph ;
Brewer, Alex J. ;
Fidel, Jennifer A. .
ANALYTICAL CHEMISTRY, 2011, 83 (07) :2622-2630
[4]   Choosing sample volume to achieve maximum detection sensitivity and resolution with high-performance liquid chromatography columns of 1.0, 2.1 and 4.6 mm ID [J].
Bakalyar, SR ;
Phipps, C ;
Spruce, B ;
Olsen, K .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :167-185
[5]   Analysis of llicit and illicit drugs in waste, surface and lake water samples using large volume direct injection high performance liquid chromatography - Electrospray tandem mass spectrometry (HPLC-MS/MS) [J].
Berset, Jean-Daniel ;
Brenneisen, Rudolf ;
Mathieu, Christoph .
CHEMOSPHERE, 2010, 81 (07) :859-866
[6]   Quantification of drugs of abuse in municipal wastewater via SPE and direct injection liquid chromatography mass spectrometry [J].
Bisceglia, Kevin J. ;
Roberts, A. Lynn ;
Schantz, Michele M. ;
Lippa, Katrice A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (06) :2701-2712
[7]   Determination of sixteen polycyclic aromatic hydrocarbons in aqueous and solid samples from an Italian wastewater treatment plant [J].
Busetti, F ;
Heitz, A ;
Cuomo, M ;
Badoer, S ;
Traverso, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) :104-115
[8]   Rapid analysis of iodinated X-ray contrast media in secondary and tertiary treated wastewater by direct injection liquid chromatography-tandem mass spectrometry [J].
Busetti, Francesco ;
Linge, Kathryn L. ;
Blythe, Justin W. ;
Heitz, Anna .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (02) :200-208
[9]   Occurrence of iodinated X-ray contrast media in indirect potable reuse systems [J].
Busetti, Francesco ;
Linge, Kathryn L. ;
Rodriguez, Clemencia ;
Heitz, Anna .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2010, 45 (05) :542-548
[10]   Large volume injection of acidic pesticides by reversed-phase micro high-performance liquid chromatography [J].
Cappiello, A ;
Famiglini, G ;
Berloni, A .
JOURNAL OF CHROMATOGRAPHY A, 1997, 768 (02) :215-222