A quantitative pressure and microbubble-size dependence study of focused ultrasound-induced blood-brain barrier opening reversibility in vivo using MRI

被引:131
|
作者
Samiotaki, Gesthimani [1 ]
Vlachos, Fotios [1 ]
Tung, Yao-Sheng [1 ]
Konofagou, Elisa E. [1 ,2 ]
机构
[1] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
[2] Columbia Univ, Dept Radiol, New York, NY 10027 USA
关键词
blood-brain barrier; focused ultrasound; Gd-DTPA-BMA; CE-T1; CONTRAST AGENT; CAVITATION THRESHOLD; MOUSE-BRAIN; DISRUPTION; MICE; PERMEABILITY; DELIVERY; MICROVESSELS; DESTRUCTION; FREQUENCIES;
D O I
10.1002/mrm.23063
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Focused ultrasound in conjunction with the systemic administration of microbubbles has been shown to open the blood-brain barrier (BBB) selectively, noninvasively and reversibly. In this study, we investigate the dependence of the BBB opening's reversibility on the peak-rarefactional pressure (0.300.60 MPa) as well as the microbubble size (diameters of 12, 45, or 68 mu m) in mice using contrast-enhanced T1-weighted (CE-T1) MR images (9.4 T). Volumetric measurements of the diffusion of Gd-DTPA-BMA into the brain parenchyma were used for the quantification of the BBB-opened region on the day of sonication and up to 5 days thereafter. The volume of opening was found to increase with both pressure and microbubble diameter. The duration required for closing was found to be proportional to the volume of opening on the day of opening, and ranged from 24 h, for the smaller microbubbles, to 5 days at high peak-rarefactional pressures. Overall, larger bubbles did not show significant differences. Also, the extent of BBB opening decreased radially towards the focal region until the BBB's integrity was restored. In the cases where histological damage was detected, it was found to be highly correlated with hyperintensity on the precontrast T1 images. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:769 / 777
页数:9
相关论文
共 50 条
  • [31] Bubble Dependence of the Mechanism of FUS-Induced Blood-Brain Barrier Opening In Mice and In Monkeys In Vivo
    Tung, Yao-Sheng
    Marquet, Fabrice
    Teichert, Tobias
    Ferrera, Vincent
    Konofagou, Elisa E.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1898 - 1901
  • [32] Permeability assessment of the focused ultrasound-induced blood-brain barrier opening using dynamic contrast-enhanced MRI
    Vlachos, F.
    Tung, Y-S
    Konofagou, E. E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18) : 5451 - 5466
  • [33] Focused Ultrasound-Induced Blood-Brain Barrier Opening to Enhance Temozolomide Delivery for Glioblastoma Treatment: A Preclinical Study
    Wei, Kuo-Chen
    Chu, Po-Chun
    Wang, Hay-Yan Jack
    Huang, Chiung-Yin
    Chen, Pin-Yuan
    Tsai, Hong-Chieh
    Lu, Yu-Jen
    Lee, Pei-Yun
    Tseng, I-Chou
    Feng, Li-Ying
    Hsu, Peng-Wei
    Yen, Tzu-Chen
    Liu, Hao-Li
    PLOS ONE, 2013, 8 (03):
  • [34] Characterization of Different Microbubbles in Assisting Focused Ultrasound-Induced Blood-Brain Barrier Opening
    Wu, Sheng-Kai
    Chu, Po-Chun
    Chai, Wen-Yen
    Kang, Shih-Tsung
    Tsai, Chih-Hung
    Fan, Ching-Hsiang
    Yeh, Chih-Kuang
    Liu, Hao-Li
    SCIENTIFIC REPORTS, 2017, 7
  • [35] Glymphatics Visualization after Focused Ultrasound-Induced Blood-Brain Barrier Opening in Humans
    Meng, Ying
    Abrahao, Agessandro
    Heyn, Chinthaka C.
    Bethune, Allison J.
    Huang, Yuexi
    Pople, Christopher B.
    Aubert, Isabelle
    Hamani, Clement
    Zinman, Lorne
    Hynynen, Kullervo
    Black, Sandra E.
    Lipsman, Nir
    ANNALS OF NEUROLOGY, 2019, 86 (06) : 975 - 980
  • [36] Focused ultrasound-induced molecular delivery through the blood-brain barrier
    Choi, James J.
    Wang, Shougang
    Morrison, Barclay, III
    Konofagou, Elisa E.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1192 - 1195
  • [37] Optimization of Blood-Brain Barrier Opening in Mice using Focused Ultrasound
    Choi, James J.
    Small, Scott A.
    Konofagou, Elisa E.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 540 - +
  • [38] Microbubble volume: A definitive dose parameter in blood-brain barrier opening by focused ultrasound
    Song, Kang-Ho
    Fan, Alexander C.
    Harvey, Brandon K.
    Borden, Mark A.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 5 - 7
  • [39] Microbubble-enhanced Focused Ultrasound-induced Blood-brain Barrier Opening for Local and Transient Drug Delivery in Central Nervous System Disease
    Fan, Ching-Hsiang
    Yeh, Chih-Kuang
    JOURNAL OF MEDICAL ULTRASOUND, 2014, 22 (04) : 183 - 193
  • [40] Effect of Microbubble Size, Composition, and Multiple Sonication Points on Sterile Inflammatory Response in Focused Ultrasound-Mediated Blood-Brain Barrier Opening
    Martinez, Payton J.
    Song, Jane J.
    Castillo, Jair I.
    DeSisto, John
    Song, Kang-Ho
    Green, Adam L.
    Borden, Mark
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2024, 10 (12): : 7451 - 7465