Effective Dose to Patients from SPECT and CT During Myocardial Perfusion Imaging

被引:7
|
作者
Brindhaban, Ajit [1 ]
机构
[1] Kuwait Univ, Dept Radiol Sci, POB 31470, Sulibikhat 90805, Kuwait
关键词
myocardial perfusion imaging; SPECT/CT; administered activity; CT dose index; effective dose; ATTENUATION CORRECTION; NATIONAL-SURVEY;
D O I
10.2967/jnmt.119.233874
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiation dose to patients from imaging modalities is measured or calculated to assess the risk of the procedure and compare it with the benefits. Periodic review of image acquisition methods and the radiation dose used are an essential part of optimization in medical imaging. The aim of this study was to estimate patient radiation dose from SPECT myocardial perfusion imaging (MPI) using CT images for attenuation correction. Methods: SPECT and CT image acquisition parameters such as administered activity (AA), CT dose index (CTDIvol), and dose-length product for 415 patients who had undergone SPECT MPI using CT attenuation correction were reviewed. Effective dose (ED) for the SPECT part, the CT part and the total ED for the procedure were calculated. AA, CTDIvol, and ED values were compared between the 2 sexes and between body mass indexes (BMIs), imaging scanner models, and imaging centers. Statistical analyses were performed using t tests and 1-way ANOVA at P < 0.05 level of significance. Results: The range of AAs used for MPI was found to be 1,206-1,964 MBq per patient regardless of sex. The resulting mean ED of 8.8 mSv for men was significantly lower (P = 0.002) than the 10.4 mSv for women for SPECT. The range of CTDIvol was 1.12-3.97 mGy, resulting in an mean ED of 0.8 mSv for men, significantly lower (P, 0.001) than the 1.1 mSv for women for CT. The average combined EDs for male and female patients were 9.6 and 11.5 mSv, respectively. A positive correlation was found between AA and patient BMI (r = 0.48; P < 0.001), indicating patient size-related AAs. However, CTDIvol was found to depend only on the scanner model, regardless of BMI. Conclusion: The ED from SPECT/CT MPI studies was around 11 mSv, with 10 mSv being from the SPECT part of the study. The extra risk to the patients from CT imaging for attenuation correction is small compared with the benefit incurred from accurate diagnosis.
引用
收藏
页码:143 / 147
页数:5
相关论文
共 50 条
  • [21] Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration
    Goetze, Sibyll
    Brown, Tracy L.
    Lavely, William C.
    Zhang, Zhe
    Bengel, Frank M.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) : 1090 - 1095
  • [22] Diagnostic reference level, achievable dose, and effective dose estimation in adult hybrid SPECT myocardial perfusion imaging in Institut Jantung Negara
    Haniff Shazwan Safwan Selvam
    Ahmad Khairuddin Mohamed Yusof
    Muhammad Azuan Nazri
    Norizan Omar
    Ali Hazizi Jamal Harizan
    Norizam Mois
    Muhd Zaidi Ab Rahman
    Scientific Reports, 15 (1)
  • [23] Myocardial perfusion imaging and coronary calcium scoring with a two-slice SPECT/CT system: can the attenuation map be calculated from the calcium scoring CT scan?
    Christian Wenning
    Kambiz Rahbar
    Alexis Vrachimis
    Otmar Schober
    Michael Schäfers
    Lars Stegger
    European Journal of Nuclear Medicine and Molecular Imaging, 2013, 40 : 1069 - 1076
  • [24] SPECT/PET myocardial perfusion imaging versus coronary CT angiography in patients with known or suspected CAD
    Berman, D. S.
    Shaw, L. J.
    Min, J. K.
    Hachamovitch, R.
    Abidov, A.
    Germano, G.
    Hayes, S. W.
    Friedman, J. D.
    Thomson, L. E. J.
    Kang, X.
    Slomka, P.
    Rozanski, A.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 54 (02) : 177 - 200
  • [25] Myocardial perfusion imaging and coronary calcium scoring with a two-slice SPECT/CT system: can the attenuation map be calculated from the calcium scoring CT scan?
    Wenning, Christian
    Rahbar, Kambiz
    Vrachimis, Alexis
    Schober, Otmar
    Schaefers, Michael
    Stegger, Lars
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (07) : 1069 - 1076
  • [26] Myocardial perfusion imaging with a novel SPECT/CT system: all that glitters is not gold
    Jyrki T. Kuikka
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 611 - 612
  • [27] Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?
    Vera Froeling
    Uwe Heimann
    Ralf-Harto Huebner
    Thomas J. Kroencke
    Martin H. Maurer
    Felix Doellinger
    Dominik Geisel
    Bernd Hamm
    Winfried Brenner
    Nils F. Schreiter
    Annals of Nuclear Medicine, 2015, 29 : 528 - 534
  • [28] Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?
    Froeling, Vera
    Heimann, Uwe
    Huebner, Ralf-Harto
    Kroencke, Thomas J.
    Maurer, Martin H.
    Doellinger, Felix
    Geisel, Dominik
    Hamm, Bernd
    Brenner, Winfried
    Schreiter, Nils F.
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (06) : 528 - 534
  • [29] Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations
    Carlos Montes
    Pilar Tamayo
    Jorge Hernandez
    Felipe Gomez-Caminero
    Sofia García
    Carlos Martín
    Angela Rosero
    Annals of Nuclear Medicine, 2013, 27 : 610 - 617
  • [30] IQ SPECT Allows a Significant Reduction in Administered Dose and Acquisition Time for Myocardial Perfusion Imaging: Evidence from a Phantom Study
    Caobelli, Federico
    Kaiser, Stefano Ren
    Thackeray, James T.
    Bengel, Frank M.
    Chieregato, Matteo
    Soffientini, Alberto
    Pizzocaro, Claudio
    Savelli, Giordano
    Galelli, Marco
    Guerra, Ugo Paolo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (12) : 2064 - 2070