Thirty-minute compared to standardised office blood pressure measurement in general practice

被引:13
作者
Scherpbier-de Haan, Nynke [1 ]
van der Wel, Mark [1 ]
Schoenmakers, Gijs [1 ]
Boudewijns, Steve [1 ]
Peer, Petronella [1 ]
van Weel, Chris [1 ]
Thien, Theo [1 ]
Bakx, Carel [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Primary & Community Care, NL-6500 HB Nijmegen, Netherlands
关键词
AMERICAN-HEART-ASSOCIATION; PRIMARY-CARE; HYPERTENSION; AGREEMENT; RECOMMENDATIONS; STATEMENT; DESIGN; HOME;
D O I
10.3399/bjgp11X593875
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background Although blood pressure measurement is one of the most frequently performed measurements in clinical practice, there are concerns about its reliability. Serial, automated oscillometric blood pressure measurement has the potential to reduce measurement bias and 'white-coat effect' Aim To study agreement of 30-minute office blood pressure measurement (OBPM) with standardised OBPM, and to compare repeatability Design and setting Method comparison study in two general practices in the Netherlands Method Thirty-minute and standardised OBPM was carried out with the same, validated device in 83 adult patients, and the procedure was repeated after 2 weeks. During 30-minute OBPM, blood pressure was measured automatically every 3 minutes, with the patient in a sitting position, alone in a quiet room. Agreement between 30-minute and standardised OBPM was assessed by Bland-Altman analysis. Repeatability of the blood pressure measurement methods after 2 weeks was expressed as the mean difference in combination with the standard deviation of difference (SDD) Results Mean 30-minute OBPM readings were 7.6/2.5 mmHg (95% confidence interval [CI] = 6.1 to 9.1/1.5 to 3.4 mmHg) lower than standardised OBPM readings. The mean difference and SDD between repeated 30-minute OBPMs (mean difference = 3/1 mmHg, 95% CI = 1 to 5/0 to 2 mmHg; SDD 9.5/5.3 mmHg) were lower than those of standardised OBPMs (mean difference = 6/2 mmHg, 95% CI = 4 to 8/1 to 4 mmHg; SDD 10.9/6.3 mmHg). Conclusion Thirty-minute OBPM resulted in lower readings than standardised OBPM and had a better repeatability. These results suggest that 30-minute OBPM better reflects the patient's true blood pressure than standardised OBPM does.
引用
收藏
页码:e590 / e597
页数:2
相关论文
共 26 条
[1]   The Effect of Measuring Ambulatory Blood Pressure on Nighttime Sleep and Daytime Activity-Implications for Dipping [J].
Agarwal, Rajiv ;
Light, Robert P. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2010, 5 (02) :281-285
[2]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Misclassification of blood pressure by usual measurement in ambulatory physician practices [J].
Campbell, NRC ;
Culleton, BW ;
McKay, DW .
AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (12) :1522-1527
[5]   Performance of the automated BpTRU™ measurement device in the assessment of white-coat hypertension and white-coat effect [J].
Culleton, BF ;
McKay, DW ;
Campbell, NR .
BLOOD PRESSURE MONITORING, 2006, 11 (01) :37-42
[6]   A practical approach to Bland-Altman plots and variation coefficients for log transformed variables [J].
Euser, Anne M. ;
Dekker, Friedo W. ;
le Cessie, Saskia .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2008, 61 (10) :978-982
[7]   How should we measure blood pressure in the doctor's office? [J].
Gerin, W ;
Marion, RM ;
Friedman, R ;
James, GD ;
Bovbjerg, DH ;
Pickering, TG .
BLOOD PRESSURE MONITORING, 2001, 6 (05) :257-262
[8]   Reliability of self-reported blood pressure measurements [J].
Johnson, KA ;
Partsch, DJ ;
Rippole, LL ;
McVey, DM .
ARCHIVES OF INTERNAL MEDICINE, 1999, 159 (22) :2689-2693
[9]   A validation of the Mobil O Graph (version 12) ambulatory blood pressure monitor [J].
Jones, CR ;
Taylor, K ;
Chowienczyk, P ;
Poston, L ;
Shennan, AH .
BLOOD PRESSURE MONITORING, 2000, 5 (04) :233-238
[10]   Comparison of acceptability of and preferences for different methods of measuring blood pressure in primary care [J].
Little, P ;
Barnett, J ;
Barnsley, L ;
Marjoram, J ;
Fitzgerald-Barron, A ;
Mant, D .
BRITISH MEDICAL JOURNAL, 2002, 325 (7358) :258-259