Performance of laboratories analysing welding fume on filter samples: Results from the WASP proficiency testing scheme

被引:17
作者
Stacey, Peter [1 ]
Butler, Owen [1 ]
机构
[1] Hlth & Safety Lab, Buxton SK17 9JN, England
关键词
air sampling; analysis; fume; proficiency testing; quality of data; WASP; welding;
D O I
10.1093/annhyg/men016
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
This paper emphasizes the need for occupational hygiene professionals to require evidence of the quality of welding fume data from analytical laboratories. The measurement of metals in welding fume using atomic spectrometric techniques is a complex analysis often requiring specialist digestion procedures. The results from a trial programme testing the proficiency of laboratories in the Workplace Analysis Scheme for Proficiency (WASP) to measure potentially harmful metals in several different types of welding fume showed that most laboratories underestimated the mass of analyte on the filters. The average recovery was 70-80% of the target value and > 20% of reported recoveries for some of the more difficult welding fume matrices were < 50%. This level of under-reporting has significant implications for any health or hygiene studies of the exposure of welders to toxic metals for the types of fumes included in this study. Good laboratories' performance measuring spiked WASP filter samples containing soluble metal salts did not guarantee good performance when measuring the more complex welding fume trial filter samples. Consistent rather than erratic error predominated, suggesting that the main analytical factor contributing to the differences between the target values and results was the effectiveness of the sample preparation procedures used by participating laboratories. It is concluded that, with practice and regular participation in WASP, performance can improve over time.
引用
收藏
页码:287 / 295
页数:9
相关论文
共 12 条
  • [1] AKANES R, 1992, QUALITY ASSURANCE WO
  • [2] AKANES R, 1990, QUALITY ASSURANCE WO
  • [3] AKANES R, 1995, QUALITY ASSURANCE WO
  • [4] IRON, MANGANESE, COPPER AND TITANIUM IN WELDING FUME DUST ON FILTERS FOR INTERNAL AND EXTERNAL QUALITY ASSURANCE
    ANGLOV, JTB
    HOLST, E
    DYG, S
    CHRISTENSEN, JM
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (2-4): : 335 - 339
  • [5] *BSI, 1991, 7384 BSI BS
  • [6] Development of an international standard for the determination of metals and metalloids in workplace air using ICP-AES: evaluation of sample dissolution procedures through an interlaboratory trial
    Butler, OT
    Howe, AM
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (01): : 23 - 32
  • [7] *HLTH SAF EX, 1998, 91 MDHS HLTH SAF EX
  • [8] *HLTH SAF EX, 2005, EH402005 HLTH SAF EX
  • [9] ISO, 2004, 152023 ISO
  • [10] ISO, 2005, 13528 ISO