The effectiveness of germicidal wipes and ultraviolet irradiation in reducing bacterial loads on electronic tablet devices used to obtain patient information in orthopaedic clinics: evaluation of tablet cleaning methods

被引:7
作者
Allen, E. M. [1 ,2 ]
McTague, M. F. [1 ,2 ]
Bay, C. P. [4 ]
Esposito, J. G. [1 ,3 ]
von Keudell, A. [1 ,2 ]
Weaver, M. J. [1 ,2 ]
机构
[1] Harvard Med Sch Orthoped Trauma Initiat, Boston, MA USA
[2] Brigham & Womens Hosp, Dept Orthoped Surg, 75 Francis St, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Dept Orthoped Surg, Boston, MA 02114 USA
[4] Brigham & Womens Hosp, Ctr Clin Invest, 75 Francis St, Boston, MA 02115 USA
关键词
Tablet; Bacteria; Orthopaedics; Ultraviolet radiation; Infection control; Disinfection; DISINFECTION; IPAD;
D O I
10.1016/j.jhin.2020.04.014
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Electronic tablet devices are commonly used in outpatient clinics to obtain patient information for both clinical and research purposes. These devices are often colonized with bacteria; there are many cleaning methods to reduce this bacterial load. Aim: The primary purpose of this study was to evaluate whether regular cleaning with either germicidal wipes or ultraviolet (UV) irradiation leads to lower bacterial levels compared with irregular cleaning. Methods: A randomized blinded trial was conducted of tablet cleaning strategies between each patient encounter in orthopaedic clinics. The cleaning method was randomized to either germicidal wipes, UV irradiation, or cleaning only when the tablet was visibly soiled. Research assistants (blinded to the treatment) obtained bacterial cultures from the tablets at the beginning and end of each clinic day. Findings: Using germicidal wipes between each patient encounter vs no routine cleaning resulted in a marked decrease in the amount of bacterial contamination (risk ratio (RR) = 0.17 (0.04-0.67)). Similarly, using UV irradiation between each patient encounter led to significantly lower bacterial contamination rates (RR = 0.29 (95% confidence interval (CI) = 0.09-0.95)) compared with no routine cleaning. The majority of bacteria identified were normal skin flora. No meticillin-resistant Staphylococcus aureus was identified and only sparse colonies of meticillin-sensitive S. aureus. Conclusion: Electronic tablets used in orthopaedic trauma clinics are colonized with bacteria if no routine cleaning is performed. Routine use of either UV irradiation or germicidal wipes significantly decreases this bacterial burden. Providers should implement routine cleaning of tablets between each patient encounter to minimize exposure to potential pathogens. (C) 2020 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:200 / 204
页数:5
相关论文
共 20 条
[1]   Standardized, App-Based Disinfection of iPads in a Clinical and Nonclinical Setting: Comparative Analysis [J].
Albrecht, Urs-Vito ;
von Jan, Ute ;
Sedlacek, Ludwig ;
Groos, Stephanie ;
Suerbaum, Sebastian ;
Vonberg, Ralf-Peter .
JOURNAL OF MEDICAL INTERNET RESEARCH, 2013, 15 (08)
[2]  
Apple Inc, 2018, IPAD US GUID SAF HAN
[3]   Evaluation of an Ultraviolet C (UVC) Light-Emitting Device for Disinfection of High Touch Surfaces in Hospital Critical Areas [J].
Casini, Beatrice ;
Tuvo, Benedetta ;
Cristina, Maria Luisa ;
Spagnolo, Anna Maria ;
Totaro, Michele ;
Baggiani, Angelo ;
Privitera, Gaetano Pierpaolo .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (19)
[4]   Healthcare workers mobile phone usage: A potential risk for viral contamination. Surveillance pilot study [J].
Cavari, Yuval ;
Kaplan, Or ;
Zander, Aviva ;
Hazan, Guy ;
Shemer-Avni, Yonat ;
Borer, Abraham .
INFECTIOUS DISEASES, 2016, 48 (06) :432-435
[5]  
Cutler Timothy D., 2011, Animal Health Research Reviews, V12, P15, DOI 10.1017/S1466252311000016
[6]   Evaluation of a pulsed xenon ultraviolet disinfection system to decrease bacterial contamination in operating rooms [J].
El Haddad, Lynn ;
Ghantoji, Shashank S. ;
Stibich, Mark ;
Fleming, Jason B. ;
Segal, Cindy ;
Ware, Kathy M. ;
Chemaly, Roy F. .
BMC INFECTIOUS DISEASES, 2017, 17
[7]   Healthcare Personnel Attire and Devices as Fomites: A Systematic Review [J].
Haun, Nicholas ;
Hooper-Lane, Christopher ;
Safdar, Nasia .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2016, 37 (11) :1367-1373
[8]  
Health Quality Ontario, 2018, Ont Health Technol Assess Ser, V18, P1
[9]   Surface Microbiology of the iPad Tablet Computer and the Potential to Serve as a Fomite in Both Inpatient Practice Settings as Well as Outside of the Hospital Environment [J].
Hirsch, Elizabeth B. ;
Raux, Brian R. ;
Lancaster, Jason W. ;
Mann, Rachael L. ;
Leonard, Steven N. .
PLOS ONE, 2014, 9 (10)
[10]   Disinfecting the iPad: evaluating effective methods [J].
Howell, V. ;
Thoppil, A. ;
Mariyaselvam, M. ;
Jones, R. ;
Young, H. ;
Sharma, S. ;
Blunt, M. ;
Young, P. .