Motion correction for gated PET using sinogram registration

被引:0
|
作者
Detorie, Nicole C. [1 ]
Dahlbom, Magnus [1 ]
机构
[1] Univ Calif Los Angeles, Dept Mol & Med Pharmacol, David Geffen Sch Med, Los Angeles, CA 90095 USA
来源
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11 | 2007年
关键词
MODE; IMAGES;
D O I
10.1109/NSSMIC.2007.4436898
中图分类号
O59 [应用物理学];
学科分类号
摘要
The aim of this study was to investigate the feasibility of a motion correction method for dynamic positron emission tomography (PET) using sinogram registration. The NCAT phantom was simulated with respiratory motion and either 10 nun or 20 nun lesions located at the upper, middle, and base of the right lung. Additionally, a Jaszczak phantom filled with F-18 was placed on a motion platform. The NCAT data were binned into 16 gates, and the Jaszczak data were binned into 12 gates. In both studies lesions had a source to background ratio of either 5:1 or 10:1, and data were reconstructed with OSEM, 4 iterations and 8 subsets. Three methods were used to obtain the transformations between each frame: non-rigid image registration, rigid image registration, and sinogram registration. The sinogram method was derived from forward projecting only the lesion from image space to projection space. The transformations were applied to the gated sinograms to produce motion corrected sinograms, which were summed prior to reconstruction and resulted in a motion corrected image volume. The mean lesion signal, lesion contrast to noise ratio (CNR), and registration accuracy were evaluated. Compared to the other motion correction methods, sinogram registration resulted in comparable or improved lesion signal recovery, lesion CNR recovery, and registration accuracy. With respect to the NCAT data, sinogram registration resulted in a 5%-23% and 5%-10% higher CNR recovery compared to the non-rigid and rigid registration, respectively. With respect to the Jaszczak data, sinogram registration resulted in a 10%-14% higher mean signal recovery of the 1 mL lesion compared to rigid registration, and a 5-25% higher CNR recovery compared to the rigid motion correction method. As lesion size and contrast decreased, the mean signal recovery and CNR recovery achieved with the motion correction methods increased.
引用
收藏
页码:3577 / 3582
页数:6
相关论文
共 50 条
  • [41] Respiratory compensated PET with DOTATOC PET/MRI using motion registered and gated reconstruction
    Tao, Dora
    Pampaloni, Miguel Hernandez
    Ravanfar, Vahid
    Nakakura, Eric
    Bergsland, Emily
    Hope, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [42] Clinical Evaluation of MR-Gated Respiratory Motion Correction in Simultaneous PET/MRI
    Li, Hui
    Meng, Xiangxi
    Guan, Xiangping
    Zhou, Nina
    Liu, Hui
    Zhang, Yan
    Yu, Boqi
    Zhu, Hua
    Li, Nan
    Yang, Zhi
    CLINICAL NUCLEAR MEDICINE, 2021, 46 (04) : 297 - 302
  • [43] PET motion correction using MR-derived motion parameters
    Matthew Bickell
    Thomas Koesters
    Fernando Boada
    Johan Nuyts
    EJNMMI Physics, 1 (Suppl 1)
  • [44] Respiratory Motion Correction of PET using Motion Parameters from MR
    Dikaios, Nikolaos
    Fryer, Tim D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2806 - 2808
  • [45] Regularized B-spline Deformable Registration for Respiratory Motion Correction in PET Images
    Bai, Wenjia
    Brady, Michael
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2977 - 2983
  • [46] Motion Correction of PET Data with a Joint Registration Functional for Multi-Modal Data
    Fieseler, Michael
    Gigengack, Fabian
    Jiang, Xiaoyi
    Schaefers, Klaus P.
    2012 INTERNATIONAL CONFERENCE ON COMPUTERIZED HEALTHCARE (ICCH), 2012, : 170 - 173
  • [47] Regularized B-spline deformable registration for respiratory motion correction in PET images
    Bai, Wenjia
    Brady, Michael
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09): : 2719 - 2736
  • [48] Misregistration correction of data-drivegated (DDG) PET/CT by self-gated PET and deformable image registration CT
    Sun, Peng
    Pan, Tinsu
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [49] Motion registration and compensation in PET imaging
    Bundschuh, R. A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S47 - S48
  • [50] Metal Artifact Reduction in CT-Based Attenuation Correction of PET using Sobolev Sinogram Restoration
    Mehranian, A.
    Ay, M. R.
    Rahmim, A.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2936 - 2942