摘要
The aim of this study was to investigate the feasibility of a motion correction method for dynamic positron emission tomography (PET) using sinogram registration. The NCAT phantom was simulated with respiratory motion and either 10 nun or 20 nun lesions located at the upper, middle, and base of the right lung. Additionally, a Jaszczak phantom filled with F-18 was placed on a motion platform. The NCAT data were binned into 16 gates, and the Jaszczak data were binned into 12 gates. In both studies lesions had a source to background ratio of either 5:1 or 10:1, and data were reconstructed with OSEM, 4 iterations and 8 subsets. Three methods were used to obtain the transformations between each frame: non-rigid image registration, rigid image registration, and sinogram registration. The sinogram method was derived from forward projecting only the lesion from image space to projection space. The transformations were applied to the gated sinograms to produce motion corrected sinograms, which were summed prior to reconstruction and resulted in a motion corrected image volume. The mean lesion signal, lesion contrast to noise ratio (CNR), and registration accuracy were evaluated. Compared to the other motion correction methods, sinogram registration resulted in comparable or improved lesion signal recovery, lesion CNR recovery, and registration accuracy. With respect to the NCAT data, sinogram registration resulted in a 5%-23% and 5%-10% higher CNR recovery compared to the non-rigid and rigid registration, respectively. With respect to the Jaszczak data, sinogram registration resulted in a 10%-14% higher mean signal recovery of the 1 mL lesion compared to rigid registration, and a 5-25% higher CNR recovery compared to the rigid motion correction method. As lesion size and contrast decreased, the mean signal recovery and CNR recovery achieved with the motion correction methods increased.
引用
收藏
页码:3577 / 3582
页数:6
相关论文
共 50 条
  • [1] Motion Correction in Dual Gated Cardiac PET Using Mass-Preserving Image Registration
    Gigengack, Fabian
    Ruthotto, Lars
    Burger, Martin
    Wolters, Carsten H.
    Jiang, Xiaoyi
    Schaefers, Klaus P.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (03) : 698 - 712
  • [2] Non-Rigid Respiratory Motion Correction for 4D Gated PET Sinogram Data
    Feng, Tao
    Tsui, Benjamin M. W.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [3] Motion correction of respiratory-gated PET images using deep learning based image registration framework
    Li, Tiantian
    Zhang, Mengxi
    Qi, Wenyuan
    Asma, Evren
    Qi, Jinyi
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (15):
  • [4] Motion Correction of Respiratory-gated PET Image Using Deep Learning Based Image Registration Framework
    Li, Tiantian
    Zhang, Mengxi
    Qi, Wenyuan
    Asma, Evren
    Qi, Jinyi
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [5] Pipeline for Motion Correction in Dual Gated PET
    Gigengack, Fabian
    Ruthotto, Lars
    Koesters, Thomas
    Jiang, Xiaoyi
    Modersitzki, Jan
    Burger, Martin
    Wolters, Carsten H.
    Schaefers, Klaus P.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2983 - +
  • [6] Motion Correction for Respiratory Gated PET Images
    Detorie, Nicole
    Dahlbom, Magnus
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3273 - 3277
  • [7] Respiratory motion correction of PET using MR-constrained PET-PET registration
    Balfour, Daniel R.
    Marsden, Paul K.
    Polycarpou, Irene
    Kolbitsch, Christoph
    King, Andrew P.
    BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [8] Respiratory motion correction of PET using MR-constrained PET-PET registration
    Daniel R. Balfour
    Paul K. Marsden
    Irene Polycarpou
    Christoph Kolbitsch
    Andrew P. King
    BioMedical Engineering OnLine, 14
  • [9] Registration-weighted motion correction for PET
    Dikaios, Nikolaos
    Fryer, Tim D.
    MEDICAL PHYSICS, 2012, 39 (03) : 1253 - 1264
  • [10] Respiratory motion correction in PET with gated PET/CT data
    Iglesias, J. E.
    Kimiaei, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S315 - S315