Phase adjustment analysis and performance of a looped thermoacoustic prime mover with compliance/resistance tube

被引:43
作者
Jin, Tao
Yang, Rui [1 ]
Wang, Yi
Liu, Yuanliang
Feng, Ye
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermoacoustic engine; Thermoacoustic prime mover; Looped structure; Phase adjustment; Onset temperature; OPERATION FEATURES; GENERATOR; REFRIGERATOR; ENGINES; ONSET;
D O I
10.1016/j.apenergy.2016.08.182
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To realize high normalized acoustic impedance and near travelling-wave acoustic field in the regenerator is the key issue for a thermoacoustic engine to be driven by low-grade heat (e.g., waste heat, geothermal energy and solar thermal energy, etc.), and a looped thermoacoustic system with the appropriate acoustic field is considered one of the promising techniques. The present work analyzes the conception and mechanism of the phase adjustment in a looped structure, based on which two phase adjustors (namely compliance tube and resistance tube) are introduced to build appropriate acoustic field. Systematic experiments have then been conducted on a looped thermoacoustic prime mover with compliance/resistance tube, and the results show that the system with appropriate compliance/resistance tube can be initiated to oscillate at quite low heating temperature, indicating the phase adjustor can help to build up proper acoustic field. The lowest onset temperature is 40 degrees C, with a compliance tube and using the CO2 of 2.37 MPa as working fluid. Features of the acoustic field, including pressure amplitude, volumetric velocity amplitude and their phase difference, have also been numerically analyzed to verify the phase adjustment mechanism. Besides, the influence of its installation position and length of the compliance tube on the performance of the prime mover has been experimentally and numerically studied. Finally, a comparison is made to analyze the similarity and difference between the performances of compliance tube and resistance tube for phase adjustment. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:290 / 298
页数:9
相关论文
共 25 条
[1]   A thermoacoustic Stirling heat engine [J].
Backhaus, S ;
Swift, GW .
NATURE, 1999, 399 (6734) :335-338
[2]   Development of a 5 kW traveling-wave thermoacoustic electric generator [J].
Bi, Tianjiao ;
Wu, Zhanghua ;
Zhang, Limin ;
Yu, Guoyao ;
Luo, Ercang ;
Dai, Wei .
APPLIED ENERGY, 2017, 185 :1355-1361
[3]  
Biwa T, 2004, PHYS REV E, V69, DOI 10.1103/PhysRevE.69.066304
[4]   PISTONLESS STIRLING ENGINE - TRAVELING WAVE HEAT ENGINE [J].
CEPERLEY, PH .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1979, 66 (05) :1508-1513
[5]  
De Blok K, 2012, 19 INT C SOUND VIBR
[6]   Basic treatment of onset conditions and transient effects in thermoacoustic Stirling engines [J].
de Waele, A. T. A. M. .
JOURNAL OF SOUND AND VIBRATION, 2009, 325 (4-5) :974-988
[7]   2-SENSOR POWER MEASUREMENTS IN LOSSY DUCTS [J].
FUSCO, AM ;
WARD, WC ;
SWIFT, GW .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 91 (04) :2229-2235
[8]   A cascade thermoacoustic engine [J].
Gardner, DL ;
Swift, GW .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 114 (04) :1905-1919
[9]   A linearly-acting variable-reluctance generator for thermoacoustic engines [J].
Hail, Claudio U. ;
Knodel, Philip C. ;
Lang, Jeffrey H. ;
Brisson, John G. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 100 :168-176
[10]   Thermodynamic characteristics during the onset and damping processes in a looped thermoacoustic prime mover [J].
Jin, Tao ;
Yang, Rui ;
Liu, Yuanliang ;
Tang, Ke .
APPLIED THERMAL ENGINEERING, 2016, 100 :1169-1172