Integration of an in-home monitoring system into home care nurses' workflow: A case study

被引:18
作者
Klemets, Joakim [1 ]
Maattala, Jukka [1 ]
Hakala, Ismo [1 ]
机构
[1] Univ Jyvaskyla, Kokkola Univ Consortium Chydenius, Talonpojankatu 2B, FI-67701 Kokkola, Finland
关键词
In-home monitoring; Home care; Nursing informatics; Qualitative research; SMART HOMES; HEALTH-CARE; TECHNOLOGIES; OUTCOMES; ELDERS; ADULTS; IMPACT; OLDER;
D O I
10.1016/j.ijmedinf.2018.12.006
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Background: The healthcare system faces a major challenge in caring for an increasingly ageing population as this task requires more resources than are currently available. Adopting monitoring technologies could enable more efficient care practices and support ageing in place. Objectives: To investigate how the use of an in-home motion monitoring system can be integrated into home care nurses' workflows and to uncover the factors behind system adoption. Design: A single case study adopting a qualitative approach. Setting: A home care unit serving older adults living in independent living residences within an apartment complex. Method: Multiple data collection methods were used including individual and group interviews, a questionnaire with open-ended questions, evaluation probes, and system log data. The qualitative material was analysed using a stepwise-deductive inductive approach. Results: A central factor behind system adoption was the perceived usefulness of gaining information about older adults' night-time activities. In particular, monitoring older adults suffering from memory disorders was considered advantageous. The information that the system provided supported nurses in health assessments and assisted in adjusting care decisions. Previous negative experiences with similar technologies initially influenced the time for adoption. Further, although nurses were closely involved in the system design process, they took some time to get acquainted with the system and to integrate its use into daily practice. System reliability and accuracy issues influenced nurses' trust in the sensory data. Conclusion: The findings suggests that in a home care setting, focusing on motion pattern monitoring for older adults with memory disorders can provide significant benefits and therefore also facilitate system adoption among nurses. Involving nurses in the design of the technology and providing opportunities to trial the system in real practice also appear to be important in achieving system adoption.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 39 条
[1]   Evolution of an Early Illness Warning System to Monitor Frail Elders in Independent Living [J].
Alexander, Gregory L. ;
Rantz, Marilyn ;
Skubic, Marjorie ;
Koopman, Richelle J. ;
Phillips, Lorraine J. ;
Guevara, Rainer D. ;
Miller, Steven J. .
JOURNAL OF HEALTHCARE ENGINEERING, 2011, 2 (03) :337-363
[2]  
[Anonymous], 2008, THESIS MASSACHUSETTS
[3]  
Bossen C., 2018, SOCIOTECHNICAL BETWI, P77, DOI [10.1016/B978-0-12-812583-0.00005-5, DOI 10.1016/B978-0-12-812583-0.00005-5]
[4]   The Use of Health Information Technology to Improve Care and Outcomes for Older Adults [J].
Bowles, Kathryn H. ;
Dykes, Patricia ;
Demiris, George .
RESEARCH IN GERONTOLOGICAL NURSING, 2015, 8 (01) :4-9
[5]   Building a context sensitive telephone: Some hopes and pitfalls for context sensitive computing [J].
Brown B. ;
Randell R. .
Computer Supported Cooperative Work (CSCW), 2004, 13 (3-4) :329-345
[6]   Attitudes and perceptions of adults of 60 years and older towards in-home monitoring of the activities of daily living with contactless sensors: An explorative study [J].
Claes, Veerle ;
Devriendt, Els ;
Tournoy, Jos ;
Milisen, Koen .
INTERNATIONAL JOURNAL OF NURSING STUDIES, 2015, 52 (01) :134-148
[7]  
Courtney Karen L, 2008, Inform Prim Care, V16, P195
[8]  
Demiris G., 2016, CONSUMER HLTH INFORM, P245, DOI [10.1007/978-3-319-19590-2_11, DOI 10.1007/978-3-319-19590-2_11]
[9]  
Gaver Bill., 1999, Interactions, V6, P21, DOI [DOI 10.1145/291224.291235, https://doi.org/10.1145/291224.291235]
[10]  
Glascock AP, 2006, J UNIVERS COMPUT SCI, V12, P59