The ED50 and ED95 of intrathecal isobaric bupivacaine with opioids for cesarean delivery

被引:91
作者
Carvalho, B
Durbin, M
Drover, DR
Cohen, SE
Ginosar, Y
Riley, ET
机构
[1] Stanford Univ, Sch Med, Dept Anesthesia, Stanford, CA 94305 USA
[2] Hadassah Hebrew Univ, Med Ctr, Dept Anesthesiol & Crit Care Med, Jerusalem, Israel
关键词
D O I
10.1097/00000542-200509000-00025
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The ideal intrathecal isobaric bupivacaine dose for cesarean delivery anesthesia is uncertain. While small doses (5-9 mg) of bupivacaine may reduce side effects such as hypotension, they potentially increase spinal anesthetic failures. This study determined the ED50 and ED95 of intrathecal isobaric bupivacaine (with adjuvant opioids) for cesarean delivery. Methods: After institutional review board approval and written informed consent were obtained, 48 parturients undergoing elective cesarean delivery under combined spinal-epidural anesthesia were enrolled in this double-blind, randomized, dose-ranging study. Patients received a 5-, 6-, 7-, 8-, 9-, 10-, 11-, or 12-mg intrathecal isobaric bupivacaine dose with 10 mu g fentanyl and 200 mu g morphine. Overall anesthetic success was recorded when no intraoperative epidural supplement was required during the cesarean delivery. ED50 and ED95 values for overall anesthetic success were determined using a logistic regression model. Results: ED50 and ED95 values for overall anesthetic success were 7.25 and 13.0 mg, respectively. No advantages for low doses could be demonstrated with regard to hypotension, nausea, vomiting, pruritus, or maternal satisfaction, although this study was underpowered to detect significant differences in secondary outcome variables. Conclusions: The ED50 and ED95 values (7.25 and 13.0 mg, respectively) for intrathecal isobaric hupivacaine in this circumstance are similar to values the authors determined recently for hyperbaric bupivacaine using similar methodology. These ED50 and ED95 values are significantly higher than those advocated in previous reports in which success was claimed using lower intrathecal bupivacaine doses. The current study used stricter criteria to define "successful" anesthesia and support the use of larger bupivacaine doses to ensure adequate patient comfort.
引用
收藏
页码:606 / 612
页数:7
相关论文
共 24 条
[1]   Low-dose bupivacaine-fentanyl spinal anesthesia for cesarean delivery [J].
Ben-David, B ;
Miller, G ;
Gavriel, R ;
Gurevitch, A .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2000, 25 (03) :235-239
[2]   Bupivacaine-sparing effect of fentanyl in spinal anesthesia for cesarean delivery [J].
Choi, DH ;
Ahn, HJ ;
Kim, MH .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2000, 25 (03) :240-245
[3]   Spinal anaesthesia for Caesarean section with bupivacaine 5 mg ml-1 in glucose 8 or 80 mg ml-1 [J].
Connolly, C ;
McLeod, GA ;
Wildsmith, JAW .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 86 (06) :805-807
[4]   The influence of baricity on the haemodynamic effects of intrathecal bupivacaine 0.5% [J].
Critchley, LAH ;
Morley, AP ;
Derrick, J .
ANAESTHESIA, 1999, 54 (05) :469-474
[5]  
Danelli G, 2001, Minerva Anestesiol, V67, P573
[6]   A randomized, double-blind, dose-response study of ondansetron in the prevention of postoperative nausea and vomiting [J].
Dershwitz, M ;
Conant, JA ;
Chang, YC ;
Rosow, CE ;
Connors, PM .
JOURNAL OF CLINICAL ANESTHESIA, 1998, 10 (04) :314-320
[7]  
FAN SZ, 1994, ANESTH ANALG, V78, P474
[8]  
FINUCANE BT, 1995, REGION ANESTH, V20, P87
[9]   ED50 and ED95 of intrathecal hyperbaric bupivacaine coadministered with opioids for cesarean delivery [J].
Ginosar, Y ;
Mirikatani, E ;
Drover, DR ;
Cohen, SE ;
Riley, ET .
ANESTHESIOLOGY, 2004, 100 (03) :676-682
[10]  
HARTWELL BL, 1991, REGION ANESTH, V16, P17