Signal intensity change on unenhanced T1-weighted images in dentate nucleus following gadobenate dimeglumine in patients with and without previous multiple administrations of gadodiamide

被引:48
|
作者
Ramalho, Joana [1 ,2 ]
Semelka, Richard C. [1 ]
AlObaidy, Mamdoh [1 ,3 ]
Ramalho, Miguel [1 ,4 ]
Nunes, Renato H. [1 ,5 ]
Castillo, Mauricio [1 ]
机构
[1] Univ North Carolina Hosp, Chapel Hill, NC 27514 USA
[2] Ctr Hosp Lisboa Cent, Lisbon, Portugal
[3] King Faisal Specialist Hosp & Res Ctr, Riyadh, Saudi Arabia
[4] Hosp Garcia de Orta, Almada, Portugal
[5] Santa Casa de Misericordia Sao Paulo, Sao Paulo, Brazil
关键词
Gadolinium deposition; Gadodiamide; Gadobenate dimeglumine; Neural tissue; Dentate nucleus; MR-IMAGES; CONTRAST AGENTS; GLOBUS-PALLIDUS; GADOLINIUM RETENTION;
D O I
10.1007/s00330-016-4269-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the impact of previous administration of gadodiamide and neural tissue gadolinium deposition in patients who received gadobenate dimeglumine. Our population included 62 patients who underwent at least three administrations of gadobenate dimeglumine, plus an additional contrast-enhanced last MRI for reference, divided into two groups: group 1, patients who in addition to gadobenate dimeglumine administrations had prior exposure to multiple doses of gadodiamide; group 2, patients without previous exposure to other gadolinium-based contrast agent (GBCAs). Quantitative analysis was performed on the first and last gadobenate dimeglumine MRIs in both groups. Dentate nucleus-to-middle cerebellar peduncle signal intensity ratios (DN/MCP) and relative change (RC) in signal over time were calculated and compared between groups using generalized additive model. Group 1 showed significant increase in baseline and follow-up DN/MCP compared to group 2 (p < 0.0001). The RC DN/MCP showed a non-statistically significant trend towards an increase in patients who underwent previous gadodiamide (p = 0.0735). There is increased T1 signal change over time in patients who underwent gadobenate dimeglumine and had received prior gadodiamide compared to those without known exposure to previous gadodiamide. A potentiating effect from prior gadodiamide on subsequent administered gadobenate dimeglumine may occur. aEuro cent Neural gadolinium deposition is associated with multiple administrations of less stable GBCAs. aEuro cent Less stable GBCA effect on subsequent more stable GBCA administrations is undetermined. aEuro cent Significant increase of DN/MCP was seen in patients with previous gadodiamide exposure. aEuro cent RC DN/MCP showed a non-significant increase in patients who received previous gadodiamide. aEuro cent Potentiating effects from prior gadodiamide on subsequent administered gadobenate dimeglumine may occur.
引用
收藏
页码:4080 / 4088
页数:9
相关论文
共 50 条
  • [31] Comparison of Unenhanced T1-Weighted Signal Intensities Within the Dentate Nucleus and the Globus Pallidus After Serial Applications of Gadopentetate Dimeglumine Versus Gadobutrol in a Pediatric Population
    Renz, Diane M.
    Kuempel, Stefanie
    Boettcher, Joachim
    Pfeil, Alexander
    Streitparth, Florian
    Waginger, Matthias
    Reichenbach, Juergen R.
    Teichgraeber, Ulf K.
    Mentzel, Hans-Joachim
    INVESTIGATIVE RADIOLOGY, 2018, 53 (02) : 119 - 127
  • [32] Pediatric Brain: No Increased Signal Intensity in the Dentate Nucleus on Unenhanced T1-weighted MR Images after Consecutive Exposure to a Macrocyclic Gadolinium-based Contrast Agent
    Radbruch, Alexander
    Haase, Robert
    Kickingereder, Philipp
    Baeumer, Philipp
    Bickelhaupt, Sebastian
    Paech, Daniel
    Wick, Wolfgang
    Schlemmer, Heinz-Peter
    Seitz, Angelika
    Bendszus, Martin
    RADIOLOGY, 2017, 283 (03) : 827 - 835
  • [33] High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-weighted MR Images: Relationship with Increasing Cumulative Dose of a Gadolinium-based Contrast Material
    Kanda, Tomonori
    Ishii, Kazunari
    Kawaguchi, Hiroki
    Kitajima, Kazuhiro
    Takenaka, Daisuke
    RADIOLOGY, 2014, 270 (03) : 834 - 841
  • [34] High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted MR Images: Comparison between Gadobutrol and Linear Gadolinium-Based Contrast Agents
    Moser, F. G.
    Watterson, C. T.
    Weiss, S.
    Austin, M.
    Mirocha, J.
    Prasad, R.
    Wang, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (03) : 421 - 426
  • [35] EVALUATION OF HIGH SIGNAL INTENSITY IN GLOBUS PALLIDUS AND DENTATE NUCLEUS ON UNENHANCED T1-WEIGHTED IMAGES AFTER ADMINISTRATION OF DOTAREM VS. GADAVIST IN BRAIN TUMOR PATIENTS WHO UNDERGO MULTIPLE MRI EVALUATIONS
    Rozenblatt, S.
    Luckman, J.
    Yust-Katz, S.
    Siegal, T.
    NEURO-ONCOLOGY, 2018, 20 : 255 - 255
  • [36] Automated workflow for volumetric assessment of signal intensity ratio on T1-weighted MR images after multiple gadolinium administrations
    Liu, Chia-Ying
    Ramos, Marc
    Moreno-Dominguez, David
    Prckovska, Vesna
    Rodrigues, Paulo
    Blank, Markus
    Moser, Franklin G.
    Agris, Jacob
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (01)
  • [37] High Signal Intensity of the Cochlear Modiolus on Unenhanced T1-Weighted Images in Classical Infratentorial Superficial Siderosis
    Matsusue, Eiji
    Inoue, Chie
    Matsumoto, Kensuke
    Tanino, Tomohiko
    Nakamura, Kazuhiko
    Fujii, Shinya
    YONAGO ACTA MEDICA, 2022, 65 (04) : 270 - 277
  • [38] No Signal Intensity Increase in the Dentate Nucleus on Unenhanced T1-weighted MR Images after More than 20 Serial Injections of Macrocyclic Gadolinium-based Contrast Agents
    Radbruch, Alexander
    Haase, Robert
    Kieslich, Pascal J.
    Weberling, Lukas D.
    Kickingereder, Philipp
    Wick, Wolfgang
    Schlemmer, Heinz-Peter
    Bendszus, Martin
    RADIOLOGY, 2017, 282 (03) : 699 - 707
  • [39] A retrospective cohort evaluation of the effect of multiple administrations of gadopentetate dimeglumine on brain magnetic resonance imaging T1-weighted signal
    Alexander J. Towbin
    Bin Zhang
    Jonathan R. Dillman
    Pediatric Radiology, 2021, 51 : 457 - 470
  • [40] A retrospective cohort evaluation of the effect of multiple administrations of gadopentetate dimeglumine on brain magnetic resonance imaging T1-weighted signal
    Towbin, Alexander J.
    Zhang, Bin
    Dillman, Jonathan R.
    PEDIATRIC RADIOLOGY, 2021, 51 (03) : 457 - 470