Measurement of Ion Concentration in the Unstirred Boundary Layer with Open Patch-Clamp Pipette: Implications in Control of Ion Channels by Fluid Flow

被引:2
|
作者
Kim, Jae Gon [1 ]
Park, Sang Woong [2 ]
Shin, Kyung Chul [1 ]
Kim, Bokyung [1 ]
Byun, Doyoung [3 ]
Bae, Young Min [1 ]
机构
[1] Konkuk Univ, Res Inst Med Sci, Sch Med, KU Open Innovat Ctr,Dept Physiol, Seoul, South Korea
[2] Eulji Univ, Dept Emergency Med Serv, Daejeon, South Korea
[3] Sungkyunkwan Univ, Dept Mech Engn, Seoul, South Korea
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2019年 / 143期
基金
新加坡国家研究基金会;
关键词
Biochemistry; Issue; 143; Fluid flow; shear force; unstirred layer; patch-clamp; Ag/AgCl reference electrode; liquid/metal junction potential; convection; ion channel; SHEAR-STRESS; TRANSPORT NUMBERS; CA2+ CHANNEL; ENDOTHELIUM; ELECTROOSMOSIS; MEMBRANES;
D O I
10.3791/58228
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Fluid flow is an important environmental stimulus that controls many physiological and pathological processes, such as fluid flow-induced vasodilation. Although the molecular mechanisms for the biological responses to fluid flow/shear force are not fully understood, fluid flow-mediated regulation of ion channel gating may contribute critically. Therefore, fluid flow/shear force sensitivity of ion channels has been studied using the patch-clamp technique. However, depending on the experimental protocol, the outcomes and interpretation of data can be erroneous. Here, we present experimental and theoretical evidence for fluid flow-related errors and provide methods for estimating, preventing, and correcting these errors. Changes in junction potential between the Ag/AgCl reference electrode and bathing fluid were measured with an open pipette filled with 3 M KCl. Fluid flow could then shift the liquid/metal junction potential to approximately 7 mV. Conversely, by measuring the voltage shift induced by fluid flow, we estimated the ion concentration in the unstirred boundary layer. In the static condition, the real ion concentrations adjacent to the Ag/AgCl reference electrode or ion channel inlet at the cell-membrane surface can reach as low as approximately 30% of that in the flow condition. Placing an agarose 3 M KCl bridge between the bathing fluid and reference electrode may have prevented this problem of junction potential shifting. However, the unstirred layer effect adjacent to the cell membrane surface could not be fixed in this way. Here, we provide a method for measuring real ion concentrations in the unstirred boundary layer with an open patch-clamp pipette, emphasizing the importance of using an agarose salt-bridge while studying fluid flow-induced regulation of ion currents. Therefore, this novel approach, which takes into consideration the real concentrations of ions in the unstirred boundary layer, may provide useful insight on the experimental design and data interpretation related to fluid shear stress regulation of ion channels.
引用
收藏
页数:9
相关论文
共 18 条
  • [1] ION CHANNELS IN THE THYLAKOID MEMBRANE (A PATCH-CLAMP STUDY)
    ENZ, C
    STEINKAMP, T
    WAGNER, R
    BIOCHIMICA ET BIOPHYSICA ACTA, 1993, 1143 (01) : 67 - 76
  • [2] Rediscovering sperm ion channels with the patch-clamp technique
    Kirichok, Yuriy
    Lishko, Polina V.
    MOLECULAR HUMAN REPRODUCTION, 2011, 17 (08) : 478 - 499
  • [3] PATCH-CLAMP STUDY OF VASCULAR PLANT CHLOROPLASTS - ION CHANNELS AND PHOTOCURRENTS
    MUNIZ, JJ
    POTTOSIN, II
    SANDOVAL, L
    JOURNAL OF BIOENERGETICS AND BIOMEMBRANES, 1995, 27 (02) : 249 - 258
  • [4] Patch-clamp technique to characterize ion channels in enlarged individual endolysosomes
    Chen, Cheng-Chang
    Cang, Chunlei
    Fenske, Stefanie
    Butz, Elisabeth
    Chao, Yu-Kai
    Biel, Martin
    Ren, Dejian
    Wahl-Schott, Christian
    Grimm, Christian
    NATURE PROTOCOLS, 2017, 12 (08) : 1639 - 1658
  • [5] PATCH-CLAMP STUDY ON ION CHANNELS IN THE TONOPLAST OF NITELLOPSIS-OBTUSA
    KATSUHARA, M
    MIMURA, T
    TAZAWA, M
    PLANT AND CELL PHYSIOLOGY, 1991, 32 (02) : 179 - 184
  • [6] RECORDING AND CONTROL OF ION-CHANNEL CURRENTS IN BILAYER AND PATCH-CLAMP EXPERIMENTS
    RING, A
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1994, 45 (04) : 311 - 320
  • [7] PATCH-CLAMP PROFILE OF ION CHANNELS IN RESTING MURINE LYMPHOCYTES-B
    MCCANN, FV
    MCCARTHY, DC
    NOELLE, RJ
    JOURNAL OF MEMBRANE BIOLOGY, 1990, 114 (02) : 175 - 188
  • [8] Nanoscale-Targeted Patch-Clamp Recordings of Functional Presynaptic Ion Channels
    Novak, Pavel
    Gorelik, Julia
    Vivekananda, Umesh
    Shevchuk, Andrew I.
    Ermolyuk, Yaroslav S.
    Bailey, Russell J.
    Bushby, Andrew J.
    Moss, Guy W. J.
    Rusakov, Dmitri A.
    Klenerman, David
    Kullmann, Dimitri M.
    Volynski, Kirill E.
    Korchev, Yuri E.
    NEURON, 2013, 79 (06) : 1067 - 1077
  • [9] Characterization of the effects of amphotericin B on ion channels in MDCK cells using the patch-clamp technique
    Hsu, SF
    Burnette, RR
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1997, 1329 (01): : 26 - 38
  • [10] Ion Channels in Native Chloroplast Membranes: Challenges and Potential for Direct Patch-Clamp Studies
    Pottosin, Igor
    Dobrovinskaya, Oxana
    FRONTIERS IN PHYSIOLOGY, 2015, 6