Hypersensitivity reactions and contrast medium injection: Are they always related?

被引:13
作者
Boehm, Ingrid [1 ]
Alfke, Heiko [2 ]
Klose, Klaus Jochen [1 ]
机构
[1] Univ Marburg, Dept Radiol, D-35039 Marburg, Germany
[2] Klinikum Ludenscheid, Dept Radiol, Ludenscheid, Germany
关键词
Adverse reaction; Contrast medium; Hypersensitivity; Causal analysis; Safety of CM-injection; ADVERSE REACTIONS; ANAPHYLAXIS; ALLERGY; SAFETY; PREVENTION; COMMITTEE; LATEX;
D O I
10.1016/j.ejrad.2010.12.049
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Hypersensitivity (allergic or non-allergic) reactions that occur after contrast medium (CM) injection are usually related to the CM. Recent studies, and case reports lack the analysis of alternate causes that could be also responsible in individual cases. Patients and methods: We investigated the individual relevant factor/causative agent of adult patients with hypersensitivity reactions that occurred in radiological units during CM-enhanced procedures (CT, angiography, urography, or MR-examinations). Both immediate and non-immediate (delayed) reactions were included. To find out the relevant agent a detailed patients' history was carefully analyzed. In addition, the records were retrospectively reviewed, and if indicated and possible laboratory (e. g. basophil activation test) and skin tests (e. g. prick) and/or provocations with CM-injections under routine conditions were performed. Results: 38 patients (men n = 21) suspected for CM-hypersensitivity reactions were identified. These reactions were in most cases mild (n = 21), moderate reactions occurred in 13 cases, and four patients had severe reactions. In 28 patients the reactions were induced by the CM (iodinated CM in 25 cases). Four patients had reactions that were not CM-related (latex allergy, adenosine reaction, vasovagal reaction, unknown cause) and in six cases the reaction was partly CM-related (immunological activation was present due to the patients' diseases). Conclusion: Our data support the hypothesis that in CM-enhanced procedures not only contrast materials but also a broad range of other factors may also induce hypersensitivity reactions. Therefore, the number of CM-induced hypersensitivity is smaller than initially suspected. The knowledge of the cause of a reaction is essential to effectively prevent its recurrence and to improve safety aspects in patients undergoing CM-injection. Larger trials should be performed to more specifically assess alternate causes in patients who acquire hypersensitivity reactions in CM-enhanced diagnostic procedures. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:368 / 372
页数:5
相关论文
共 27 条
[1]  
Ay D, 2009, AM J EMERG MED, V27, p[130, e1]
[2]   Heparin-induced recurrent anaphylaxis [J].
Berkun, Y ;
Haviv, YS ;
Schwartz, LB ;
Shalit, M .
CLINICAL AND EXPERIMENTAL ALLERGY, 2004, 34 (12) :1916-1918
[3]   Safety of adenosine stress magnetic resonance imaging using a mobile cardiac magnetic resonance system [J].
Bernhardt, Peter ;
Steffens, Michael ;
Kleinertz, Klaus ;
Morell, Roland ;
Budde, Rainer ;
Leischik, Roman ;
Kraemer, Alfred ;
Overhoff, Ulrich ;
Strohm, Oliver .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (03) :475-478
[4]   Contrast Medium and Patients at Risk: Asthma [J].
Boehm, I. .
ACTA RADIOLOGICA, 2009, 50 (03) :348-348
[5]  
Böhm I, 2008, ROFO-FORTSCHR RONTG, V180, P1127, DOI 10.1055/s-2008-1027771
[6]   Fixed drug eruption induced by an iodinated non-ionic X-ray contrast medium:: a practical approach to identify the causative agent and to prevent its recurrence [J].
Boehm, Ingrid ;
Medina, Jesus ;
Prieto, Pilar ;
Block, Wolfgang ;
Schild, Hans H. .
EUROPEAN RADIOLOGY, 2007, 17 (02) :485-489
[7]   Pilot study on basophil activation induced by contrast medium [J].
Boehm, Ingrid ;
Speck, Ulrich ;
Schild, Hans H. .
FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2011, 25 (02) :267-276
[8]   Latex allergy in patients suspected for contrast medium hypersensitivity: A neglected differential diagnosis [J].
Boehm, Ingrid .
ACTA RADIOLOGICA, 2010, 51 (06) :709-710
[9]  
Bohm I., 2007, EUR J RADIOL EXTRA, V61, P129, DOI [10.1016/j.ejrex.2006.12.005, DOI 10.1016/J.EJREX.2006.12.005]
[10]   Skin testing in patients with hypersensitivity reactions to iodinated contrast media - a European multicenter study [J].
Brockow, K. ;
Romano, A. ;
Aberer, W. ;
Bircher, A. J. ;
Barbaud, A. ;
Bonadonna, P. ;
Faria, E. ;
Kanny, G. ;
Lerch, M. ;
Pichler, W. J. ;
Ring, J. ;
Cernadas, J. Rodrigues ;
Tomaz, E. ;
Demoly, P. ;
Christiansen, C. .
ALLERGY, 2009, 64 (02) :234-241