Impedance and admittance control for respiratory-motion compensation during robotic needle insertion - a preliminary test

被引:12
作者
Kim, Yeoun Jae [1 ]
Seo, Jong Hyun [1 ]
Kim, Hong Rae [1 ]
Kim, Kwang Gi [1 ,2 ]
机构
[1] Natl Canc Ctr, Biomed Engn Branch, 323 Ilsan Ro, Goyang Si 410769, Gyeonggi Do, South Korea
[2] Dept Biomed Engn, Incheon, South Korea
基金
新加坡国家研究基金会;
关键词
admittance control; biopsy; impedance control; respiratory-motion compensation; robotic needle insertion; Stewart-Gough platform; ASPIRATION BIOPSY; SYSTEM;
D O I
10.1002/rcs.1795
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Many robotic needle-biopsy systems have been developed to enhance the accuracy of needle-biopsy intervention. These systems can reduce the intervention time and the radiation exposure of clinicians. However, respiratory-motion compensation is needed to ensure the accuracy and efficiency of needle biopsy intervention. Methods Human respiratory-motion data were acquired using three inertial measurement units (IMUs), and respiratory motion was simulated using the Stewart-Gough platform. Robotic needle intervention was performed using impedance and admittance control algorithms for respiratory-motion compensation using the Stewart-Gough platform and a gelatin phantom. Results The impedance and admittance control algorithms can be used to compensate for respiratory motion during robotic needle insertion. The admittance control algorithm exhibits better performance than the impedance control algorithm. Conclusions The impedance and admittance control algorithms can be applied for respiratory-motion compensation during robotic needle insertion. However, further study is needed for them to become clinically feasible.
引用
收藏
页数:10
相关论文
共 31 条
[1]   Fine-needle aspiration biopsy [J].
Amedee, RG ;
Dhurandhar, NR .
LARYNGOSCOPE, 2001, 111 (09) :1551-1557
[2]  
An CH, 2002, IEEE INT C ROB AUT
[3]  
[Anonymous], MED IMAGE COMPUT ASS
[4]   Intelligent control algorithms for robotic-assisted beating heart surgery [J].
Bebek, Oezkan ;
Cavusoglu, M. Cenk .
IEEE TRANSACTIONS ON ROBOTICS, 2007, 23 (03) :468-480
[5]  
BERGSTROM J, 1975, SCAND J CLIN LAB INV, V35, P606
[6]  
Cavusoglu MC, 2005, 2005 12TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS, P431
[7]   Vision-based variable impedance control with oscillation observer for respiratory motion compensation during robotic needle insertion: a preliminary test [J].
Cho, Chang Nho ;
Seo, Jong Hyun ;
Kim, Hong Rae ;
Jung, Hyunchul ;
Kim, Kwang Gi .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2015, 11 (04) :502-511
[8]  
DEGOULANGE E, 1994, J ROBOTIC SYST, V11, P523, DOI 10.1002/rob.4620110607
[9]   FINE-NEEDLE ASPIRATION BIOPSY OF THE THYROID - AN APPRAISAL [J].
GHARIB, H ;
GOELLNER, JR .
ANNALS OF INTERNAL MEDICINE, 1993, 118 (04) :282-289
[10]  
Hogan N., 1984, P 1984 AM CONTR C SA, P304, DOI DOI 10.23919/ACC.1984.4788393