Angle-stable and compressed angle-stable locking for tibiotalocalcaneal arthrodesis with retrograde intramedullary nails

被引:32
作者
Muckley, Thomas [1 ]
Hoffmeier, Konrad [1 ]
Klos, Kajetan [1 ]
Petrovitch, Alexander [1 ]
von Oldenburg, Geert [1 ]
Hofmann, Gunther O. [1 ]
机构
[1] Univ Jena, Dept Traumatol Hand & Reconstruct Surg, D-07740 Jena, Germany
关键词
D O I
10.2106/JBJS.G.00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Retrograde intramedullary nailing is an established procedure for tibiotalocalcaneal arthrodesis. The goal of this study was to evaluate the effects of angle-stable locking or compressed angle-stable locking on the initial stability of the nails and on the behavior of the constructs under cyclic loading conditions. Methods: Tibiotalocalcaneal arthrodesis was performed in fifteen third-generation synthetic bones and twenty-four fresh-frozen cadaver legs with use of retrograde intramedullary nailing with three different locking modes: a Stryker nail with compressed angle-stable locking, a Stryker nail with angle-stable locking, and a statically locked Biomet nail. Analyses were performed of the initial stability of the specimens (range of motion) and the laxity of the constructs (neutral zone) in dorsiflexion/plantar flexion, varus/valgus, and external rotation/internal rotation. Cyclic testing up to 100,000 cycles was also performed. The range of motion and the neutral zone in dorsiflexion/plantar flexion at specific cycle increments were determined. Results: In both bone models, the intramedullary nails with compressed angle-stable locking and those with angle-stable locking were significantly superior, in terms of a smaller range of motion and neutral zone, to the statically locked nails. The compressed angle-stable nails were superior to the angle-stable nails only in the synthetic bone model, in external/internal rotation. Cyclic testing showed the nails with angle-stable locking and those with compressed angle-stable locking to have greater stability in both models. In the synthetic bone model, compressed angle-stable locking was significantly better than angle-stable locking; in the cadaver bone model, there was no significant difference between these two locking modes. During cyclic testing, five statically locked nails in the cadaver bone model failed, whereas one nail with angle-stable locking and one with compressed angle-stable locking failed. Conclusions: Regardless of the bone model, the nails with angle-stable or compressed angle-stable locking had better initial stability and better stability following cycling than did the nails with static locking. Clinical Relevance: Angle-stable locking of retrograde nails used for tibiotalocalcaneal arthrodesis can enhance construct stability in the hindfoot and may reduce loosening, which may help to improve the clinical outcome.
引用
收藏
页码:620 / 627
页数:8
相关论文
共 15 条
[1]   Biomechanical comparison of intramedullary nail and blade plate fixation for tibiotalocalcaneal arthrodesis [J].
Alfahd, UA ;
Roth, SE ;
Stephen, D ;
Whyne, CM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (10) :703-708
[2]   A biomechanical comparison of intramedullary nail and crossed lag screw fixation for tibiotalocalcaneal arthrodesis [J].
Berend, ME ;
Glisson, RR ;
Nunley, JA .
FOOT & ANKLE INTERNATIONAL, 1997, 18 (10) :639-643
[3]   Evaluation of compression in intramedullary hindfoot arthrodesis [J].
Berson, L ;
McGarvey, WC ;
Clanton, TO .
FOOT & ANKLE INTERNATIONAL, 2002, 23 (11) :992-995
[4]   Intramedullary rod fixation compared with blade-plate-and-screw fixation for tibiotalocalcaneal arthrodesis: A biomechanical investigation [J].
Chiodo, CP ;
Acevedo, JI ;
Sammarco, VJ ;
Parks, BG ;
Boucher, HR ;
Myerson, MS ;
Schon, LC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12) :2425-2428
[5]   Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[6]   Mechanical validation of whole bone composite tibia models [J].
Cristofolini, L ;
Viceconti, M .
JOURNAL OF BIOMECHANICS, 2000, 33 (03) :279-288
[7]  
Fleming S S, 1998, J South Orthop Assoc, V7, P19
[8]   A BIOMECHANICAL COMPARATIVE-ANALYSIS OF 2 TECHNIQUES FOR TIBIOTALAR ARTHRODESIS [J].
FRIEDMAN, RL ;
GLISSON, RR ;
NUNLEY, JA .
FOOT & ANKLE INTERNATIONAL, 1994, 15 (06) :301-305
[9]   Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing -: Study of a displaced osteotomy model in sheep tibiae [J].
Kaspar, K ;
Schell, H ;
Seebeck, P ;
Thompson, MS ;
Schütz, M ;
Haas, NP ;
Duda, GN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :2028-2037
[10]  
KUNTSCHER G, 1962, PRAXIS MARKNAGELUNG, P349