Challenging loop-mediated isothermal amplification (LAMP) technique for molecular detection of Toxoplasma gondii

被引:41
作者
Fallahi, Shirzad [1 ]
Mazar, Zahra Arab [2 ]
Ghasemian, Mehrdad [3 ]
Haghighi, Ali [2 ]
机构
[1] Lorestan Univ Med Sci, Sch Med, Dept Med Parasitol & Mycol, Khorrarnabad, Iran
[2] Shahid Beheshti Univ Med Sci, Sch Med, Dept Med Parasitol & Mycol, Tehran, Iran
[3] Iran Univ Med Sci, Sch Med, Dept Med Parasitol & Mycol, Tehran, Iran
关键词
LAMP; Nested-PCR; Molecular detection; Toxoplasma gondii; POLYMERASE-CHAIN-REACTION; REAL-TIME PCR; RAPID DETECTION; BLOOD-SAMPLES; B1; GENE; DIAGNOSIS; INFECTIONS; ASSAY; DNA; IDENTIFICATION;
D O I
10.1016/S1995-7645(14)60345-X
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective: To compare analytical sensitivity and specificity of a newly described DNA amplification technique. LAMP and nested PCR assay targeting the RE and B I genes for the detection of Toxoplasma gondii (T. gondii) DNA. Methods: The analytical sensitivity of LAMP and nested-PCR was obtained against 10-fold serial dilutions of T. gondii DNA ranging from I ng to 0.01 fg. DNA samples of other parasites and human chromosomal DNA were used to determine the specificity of molecular assays. Results: After testing LAMP and nested-PCR in duplicate, the detection limit of RE-LAMP. B1-LAMP, RE-nested PCR and B1-nested PCR assays was one fg, 100 fg, 1 pg and 10 pg of T. gondii DNA respectively. All the LAMP assays and nested PCRs were 100% specific. The RE-LAMP assay revealed the most sensitivity for the detection of T. gondii DNA. Conclusions: The obtained results demonstrate that the LAMP technique has a greater sensitivity for detection of T. gondii. Furthermore, these findings indicate that primers based on the RE are more suitable than those based on the B I gene. However, the B1-LAMP assay has potential as a diagnostic tool for detection of T. gondii.
引用
收藏
页码:366 / 372
页数:7
相关论文
共 47 条
[21]  
Kotresha D, 2012, TROP BIOMED, V29, P129
[22]   Development of loop-mediated isothermal amplification (LAMP) as a diagnostic tool of toxoplasmosis [J].
Krasteva, D. ;
Toubiana, M. ;
Hartati, Sri ;
Kusumawati, Asmarani ;
Dubremetz, J. F. ;
Widada, J. Sri .
VETERINARY PARASITOLOGY, 2009, 162 (3-4) :327-331
[23]   Loop-mediated isothermal amplification for detection of African trypanosomes [J].
Kuboki, N ;
Inoue, N ;
Sakurai, T ;
Di Cello, F ;
Grab, DJ ;
Suzuki, H ;
Sugimoto, C ;
Igarashi, I .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (12) :5517-5524
[24]   Detection of Early and Single Infections of Schistosoma japonicum in the Intermediate Host Snail, Oncomelania hupensis, by PCR and Loop-Mediated Isothermal Amplification (LAMP) Assay [J].
Kumagai, Takashi ;
Furushima-Shimogawara, Rieko ;
Ohmae, Hiroshi ;
Wang, Tian-Ping ;
Lu, Shaohong ;
Chen, Rui ;
Wen, Liyong ;
Ohta, Nobuo .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2010, 83 (03) :542-548
[25]   Specific, Sensitive, and Rapid Diagnosis of Active Toxoplasmosis by a Loop-Mediated Isothermal Amplification Method Using Blood Samples from Patients [J].
Lau, Yee Ling ;
Meganathan, Puviarasi ;
Sonaimuthu, Parthasarathy ;
Thiruvengadam, Girija ;
Nissapatorn, Veeranoot ;
Chen, Yeng .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (10) :3698-3702
[26]   Development of Loop-Mediated Isothermal Amplification Assay for Detection of Entamoeba histolytica [J].
Liang, Shih-Yu ;
Chan, Yun-Hsien ;
Hsia, Kan-Tai ;
Lee, Jing-Lun ;
Kuo, Ming-Chu ;
Hwa, Kuo-Yuan ;
Chan, Chi-Wen ;
Chiang, Ting-Yi ;
Chen, Jung-Sheng ;
Wu, Fang-Tzy ;
Ji, Dar-Der .
JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (06) :1892-1895
[27]   Comparison of loop-mediated isothermal amplification (LAMP) and real-time PCR method targeting a 529-bp repeat element for diagnosis of toxoplasmosis [J].
Lin, Zhibing ;
Zhang, Yanlei ;
Zhang, Houshuang ;
Zhou, Yongzhi ;
Cao, Jie ;
Zhou, Jinlin .
VETERINARY PARASITOLOGY, 2012, 185 (2-4) :296-300
[28]   Development of a visual loop-mediated isothermal amplification method for rapid detection of the bacterial pathogen Pseudomonas putida of the large yellow croaker (Pseudosciaena crocea) [J].
Mao, Zhijuan ;
Qiu, Yangyu ;
Zheng, Lei ;
Chen, Jigang ;
Yang, Jifang .
JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 89 (03) :179-184
[29]   Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation [J].
Mori, Y ;
Nagamine, K ;
Tomita, N ;
Notomi, T .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2001, 289 (01) :150-154
[30]   Accelerated reaction by loop-mediated isothermal amplification using loop primers [J].
Nagamine, K ;
Hase, T ;
Notomi, T .
MOLECULAR AND CELLULAR PROBES, 2002, 16 (03) :223-229