Computed tomography evaluation of total knee arthroplasty implants position after two different surgical methods of implantation

被引:11
作者
Benazzo, Francesco [1 ]
Rossi, Stefano Marco Paolo [1 ]
Danesino, Gianmarco [2 ]
Klersy, Catherine [3 ]
Perelli, Simone [1 ]
Ghiara, Matteo [1 ]
机构
[1] Univ Pavia, Dept Clin Surg Sci Diagnost & Pediat, Operat Unit Orthopaed & Traumatol, Fdn IRCCS Policlin San Matteo, Via Golgi 19, I-27100 Pavia, Italy
[2] Fdn IRCCS Policlin San Matteo, Intervent & Diagnost Radiol & Neuroradiol, Pavia, Italy
[3] Fdn IRCCS Policlin San Matteo, Clin Epidemiol & Biometry, Pavia, Italy
关键词
CT measurement TKA rotation; Personalized TKA design; Measured resection and gap balancing; Blended technique with tensor; FEMORAL COMPONENT ROTATION; PAIN;
D O I
10.1007/s00264-018-4180-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe objectives of this study were to determine the reliability of a novel method of measuring the rotational alignment of an anatomical tibial tray, the difference in the rotational alignment of the femoral and tibial component according to pure measured resection or blended technique with tensor, and, finally, the difference in terms of clinical results according to the two different methods.Patients and methodsWe performed a total of 60 consecutive TKAs: 30 according to pure measured resection and 30 according to blended technique with tensor (FuZion (R)). Clinical scores and CT scan were done at sixmonths to measure patient's outcome and prosthetic components rotation.ResultsThe method of measurement of tibial tray had high agreement between different radiological observers. Mean external rotation alignment of the femur was 2.7 degrees in standard group and 0.5 degrees in the FuZion (R) group. For all clinical indices, we observed a large and significant improvement at follow-up, better in blended technique group, but without a clear superiority, and no statistically significant difference was evident between the two groups. At follow-up, HSS was to 89.7 in the FuZion (R) group and 89.0 in the standard group, KSS (clinical) was 92.6 in and 91.3 respectively, and KSS (Functional) was 91.0 in the FuZion (R) group and 87.6 in the standard group.ConclusionsOur CT measurement method is reliable and reproducible. All patients operated with this personalized knee system design obtained excellent results; the customization of femoral rotation with a blended technique is, probably, the key to optimize the outcomes and achieve the state of forgotten knee.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 20 条
[1]   Internal Rotation of the Tibial Component is Frequent in Stiff Total Knee Arthroplasty [J].
Bedard, Martin ;
Vince, Kelly G. ;
Redfern, John ;
Collen, Stacy R. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) :2346-2355
[2]   The trivector approach for minimally invasive total knee arthroplasty: A technical note [J].
Benazzo F. ;
Rossi S.M.P. .
Journal of Orthopaedics and Traumatology, 2012, 13 (3) :159-162
[3]   Rotational instability and malrotation after total knee arthroplasty [J].
Berger, RA ;
Rubash, HE .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (04) :639-+
[4]   Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty [J].
Boldt, J. G. ;
Stiehl, J. B. ;
Hodler, J. ;
Zanetti, M. ;
Munzinger, U. .
INTERNATIONAL ORTHOPAEDICS, 2006, 30 (05) :420-425
[5]   What are the factors of residual pain after uncomplicated TKA? [J].
Bonnin, Michel P. ;
Basiglini, Luca ;
Archbold, H. A. Pooler .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (09) :1411-1417
[6]   Gap Balancing vs. Measured Resection Technique in Total Knee Arthroplasty [J].
Daines, Brian K. ;
Dennis, Douglas A. .
CLINICS IN ORTHOPEDIC SURGERY, 2014, 6 (01) :1-8
[7]   The use of tibial tuberosity-trochlear groove indices based on joint size in lower limb evaluation [J].
Ferlic, Peter Wilhelm ;
Runer, Armin ;
Dirisamer, Florian ;
Balcarek, Peter ;
Giesinger, Johannes ;
Biedermann, Rainer ;
Liebensteiner, Michael Christian .
INTERNATIONAL ORTHOPAEDICS, 2018, 42 (05) :995-1000
[8]   Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation? [J].
Figueroa, Jose ;
Pablo Guarachi, Juan ;
Matas, Jose ;
Arnander, Magnus ;
Orrego, Mario .
INTERNATIONAL ORTHOPAEDICS, 2016, 40 (04) :709-714
[9]  
Ghiara M, 2013, J ORTHOP TRAUMA S1, V14, pS111
[10]  
Ghiara M, 2013, J ORTHOP TRAUMA S1, V14, pS109