Evaluation of reconstructed images with different voxel sizes of acquisition in the diagnosis of simulated external root resorption using cone beam computed tomography

被引:39
作者
Neves, F. S. [1 ]
Vasconcelos, T. V. [1 ]
Vaz, S. L. A. [1 ]
Freitas, D. Q. [1 ]
Haiter-Neto, F. [1 ]
机构
[1] Univ Estadual Campinas, Dept Oral Diag, Piracicaba Dent Sch, Div Oral Radiol, BR-3414903 Piracicaba, SP, Brazil
关键词
cone beam computed tomography; external root resorption; noise; voxel size; ORTHODONTIC TREATMENT; IN-VITRO; RADIOGRAPHY; MANAGEMENT; ACCURACY; ABILITY;
D O I
10.1111/j.1365-2591.2011.01966.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate the diagnosis of simulated external root resorption in cone beam computed tomography (CBCT) images acquired with different voxel sizes, then reconstructed with the same voxel size. Methodology Buccal, mesial and distal root surfaces of twenty single-rooted premolar teeth were evaluated for the presence or absence of simulated resorption defects. Images were obtained using a Classic i-CAT CBCT unit with two different voxel sizes (0.25 and 0.30 mm). Then all images were reconstructed to 0.25 mm voxel size. The McNemars test was applied to evaluate the agreement between the two protocols (different voxel sizes/reconstruction parameters) with the gold standard (defects created in the root). Accuracy, sensitivity, specificity, positive and negative predictive values were calculated for each voxel and defect sizes. Results Better sensitivity and accuracy were obtained with 0.25 (0.25 mm) voxel size. Specificity, positive and negative predictive values were highest with the 0.25 (0.30 mm) voxel size. McNemars test results revealed significant differences between the protocols with the gold standard (P < 0.0001). The results revealed that as the cavity size increased, sensitivity, accuracy, positive and negative predictive values also increased. When correlating the voxel size and root third, better sensitivity, accuracy, positive and negative predictive values were obtained in the middle third. Conclusions In the diagnosis of simulated external root resorption with the Classic i-CAT CBCT unit, images acquired with 0.30 mm voxel size and reconstructed with 0.25 mm voxel size provided the best protocol with a lower radiation dose than the 0.25 mm voxel size.
引用
收藏
页码:234 / 239
页数:6
相关论文
共 29 条
[11]   Density value means in the evaluation of external apical root resorption:: an in vitro study for early detection in orthodontic case simulations [J].
Eraso, F. E. ;
Parks, E. T. ;
Roberts, W. E. ;
Hohlt, W. F. ;
Ofner, S. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (03) :130-137
[12]   Method to Evaluate Inflammatory Root Resorption by Using Cone Beam Computed Tomography [J].
Estrela, Carlos ;
Bueno, Mike Reis ;
Goncalves De Alencar, Ana Helena ;
Mattar, Rinaldo ;
Valladares Neto, Jose ;
Azevedo, Bruno Correa ;
De Araujo Estrela, Cyntia Rodrigues .
JOURNAL OF ENDODONTICS, 2009, 35 (11) :1491-1497
[13]   Detection and size differentiation of simulated tooth root defects using flat-panel volume computerized tomography (fpVCT) [J].
Hahn, Wolfram ;
Fricke-Zech, Susanne ;
Fricke, Julia ;
Gruber, Rudolf M. ;
Dullin, Christian ;
Zapf, Antonia ;
Hannig, Christian ;
Kubein-Meesenburg, Dietmar ;
Sadat-Khonsari, Reza .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (02) :272-278
[14]   Operational principles for cone-beam computed tomography [J].
Hatcher, David C. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10) :3S-6S
[15]   The current status of cone beam computed tomography imaging in orthodontics [J].
Kapila, S. ;
Conley, R. S. ;
Harrell, W. E., Jr. .
DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (01) :24-34
[16]   Radiographic diagnosis of root resorption in relation to orthodontics [J].
Leach, HA ;
Ireland, AJ ;
Whaites, EJ .
BRITISH DENTAL JOURNAL, 2001, 190 (01) :16-22
[17]   Long-term follow-up of maxillary incisors with severe apical root resorption [J].
Levander, E ;
Malmgren, O .
EUROPEAN JOURNAL OF ORTHODONTICS, 2000, 22 (01) :85-92
[18]   A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT) Part I. On subjective image quality [J].
Liang, Xin ;
Jacobs, Reinhilde ;
Hassan, Bassam ;
Li, Limin ;
Pauwels, Ruben ;
Corpas, Livia ;
Souza, Paulo Couto ;
Martens, Wendy ;
Shahbazian, Maryam ;
Alonso, Arie ;
Lambrichts, Ivo .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (02) :265-269
[19]   Influence of Voxel Size in the Diagnostic Ability of Cone Beam Tomography to Evaluate Simulated External Root Resorption [J].
Liedke, Gabriela Salatino ;
Dias da Silveira, Heloisa Emilia ;
Dias da Silveira, Heraldo Luis ;
Dutra, Vinicius ;
Poli de Figueiredo, Jose Antonio .
JOURNAL OF ENDODONTICS, 2009, 35 (02) :233-235
[20]   Conebeam CT of the Head and Neck, Part 1: Physical Principles [J].
Miracle, A. C. ;
Mukherji, S. K. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (06) :1088-1095