Flashover improvement of polluted high voltage insulators by nonlinear nanofilled hydrophobic coating

被引:7
|
作者
Ibrahim, Mohamed E. [1 ]
Sabiha, Nehmdoh A. [1 ]
Izzularab, Mohamed A. [1 ]
机构
[1] Menoufia Univ, High Voltage & Dielect Mat Lab, Fac Engn, Shibin Al Kawm 32511, Egypt
关键词
Coating; Flashover; High voltage insulators; Nanotechnology; PERFORMANCE; SURFACES;
D O I
10.1016/j.epsr.2016.04.025
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a model for computing the dry band arcing voltage is proposed and verified by experiments on glass specimens coated with the nanofilled material with different characteristics. Such coating is to increase the dry band arcing voltage which leads to a better flashover performance of high voltage insulators. Then, a simple technique to enhance the flashover performance of high voltage insulators is presented. The proposed technique depends on coating only the insulator metal cap and pin. Studying the effect of RTV silicone rubber for metal cap and pin coating is presented and about 200% (on average) flashover performance improvement is achieved. Enhancing the cap and pin coating with a thin layer of the nonlinear nanofilled material, the flashover performance is improved by about 235% (on average). Finally, a model based on developing Obenaus's model for computing the flashover voltage is proposed. A good agreement between experimental and model results is achieved. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:821 / 829
页数:9
相关论文
共 50 条
  • [1] Nanofilled Nonlinear Coating Material for Improving Proactive Flashover Performance of High Voltage Insulators
    Ibrahim, Mohamed E.
    Sabiha, Nehmdoh A.
    Izzularab, Mohamed A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (05) : 2156 - 2163
  • [2] Modeling of altitude effects on AC flashover of polluted high voltage insulators
    Rizk, FAM
    Rezazada, AQ
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (02) : 810 - 822
  • [3] CALCULATION OF DC AND AC FLASHOVER VOLTAGE OF POLLUTED INSULATORS
    GUAN, ZC
    ZHANG, R
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1990, 25 (04): : 723 - 729
  • [4] Observation of Surface Flashover Process on High Voltage Polluted Insulators Near Shoreline
    Hussain, M. Majid
    Farokhi, S.
    McMeekin, S. G.
    Farzaneh, M.
    2016 IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), VOLS 1-2, 2016, : 764 - 767
  • [5] Using correced criteria to model flashover voltage of polluted insulators
    Ziari, Iman
    Gholami, Ahmad
    Jalilian, Afireza
    PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 262 - 266
  • [6] Flashover dynamic model of polluted insulators under ac voltage
    Dhahbi-Megriche, N
    Beroual, A
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2000, 7 (02) : 283 - 289
  • [7] Using corrected criteria to model flashover voltage of polluted insulators
    Ziari, Iman
    Gholami, Ahmad
    Jalilian, Alireza
    First International Power & Energy Conference (PECon 2006), Proceedings, 2006, : 602 - 606
  • [8] The pollution flashover on high voltage insulators
    Gencoglu, Muhsin Tunay
    Cebeci, Mehmet
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (11) : 1914 - 1921
  • [9] FLASHOVER MECHANISM OF HIGH VOLTAGE INSULATORS
    Rahal, A.M.
    Huraux, C.
    1979,
  • [10] Calculation of AC flashover voltage of polluted double-shed insulators
    Chen, Li-Qin
    Zhou, Jun
    Shi, Wei-Dong
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (04): : 952 - 956