Knee Capsule Anatomy: An MR Imaging and Cadaveric Study

被引:3
作者
Zibis, Aristeidis H. [1 ]
Vassalou, Evangelia E. [2 ,3 ]
Raoulis, Vasileios A. [1 ]
Lampridis, Vasileios [4 ]
Klontzas, Michail E. [2 ,5 ]
Fyllos, Apostolos [1 ]
Stavlas, Panagiotis [6 ]
Karantanas, Apostolos H. [2 ,5 ]
机构
[1] Univ Thessaly, Anat Lab, Dept Med, Sch Hlth Sci, 3 Univ Str, Biopolis 41110, Larissa, Greece
[2] Univ Hosp, Dept Med Imaging, Iraklion 71500, Greece
[3] Gen Hosp Sitia, Dept Med Imaging, Sitia 72300, Greece
[4] 424 Mil Gen Hosp, Dept Trauma & Orthopaed, Peripheriaki Odos Efkarpias, Thessaloniki 56429, Greece
[5] Univ Crete, Sch Med, Dept Radiol, Iraklion 71500, Greece
[6] Thriasio Gen Hosp, Dept Orthopaed, Athens 19600, Greece
关键词
external fixator; knee joint capsule; intra-capsular insertion; MR imaging/knee joint; MR arthrography; cadavers/knee joint; EXTRACAPSULAR PLACEMENT; EXTERNAL FIXATION; DISTAL; JOINT; PIN;
D O I
10.3390/diagnostics11111965
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This research focuses on the anatomical insertion of the synovial capsule around the knee. The attachments of the capsule were measured in 50 knee MR imaging studies with large intraarticular effusion. Corresponding measurements were performed in 20 fresh frozen cadaveric specimens, for validation. Femoral and tibial capsular reflections were defined as the distances between the attachment sites of the capsule and the femoral or tibial joint line and they were recorded in three coronal planes (anterior/middle/posterior). On MR imaging, the lateral/medial femoral capsular reflection mean values were 6.5/4.57 cm, 2.74/1.74 cm and 1.52/1.99 cm in the anterior, middle and posterior plane, respectively. MR imaging-based measurements did not differ significantly compared to corresponding cadaveric measurements. The mean values of the lateral/medial tibial capsular reflection on MR imaging were 0.09/0.11 cm, 0.34/0.26 cm and 0.62/0.34 cm in the anterior, middle and posterior plane, respectively. On cadaveric dissection, the maximum mean value was 1.45 cm, measured on the lateral side of the anterior plane. Apart from the lateral aspect of the posterior plane, MR imaging measurements were significantly lower, compared to the corresponding cadaveric measurements. The greatest femoral and tibial capsular reflections were found on the anterior and lateral side of the anterior plane. MR imaging appears to underestimate the distal extent of the knee capsule. Anatomical details of the knee capsule should be considered for safe insertion of external fixator pins.
引用
收藏
页数:10
相关论文
共 18 条
  • [11] MAHAN J, 1991, ORTHOPEDICS, V14, P305
  • [12] The volume of the human knee joint
    Matziolis, Georg
    Roehner, Eric
    Windisch, Christoph
    Wagner, Andreas
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (10) : 1401 - 1403
  • [13] Are Distal Femoral Traction Pins Intra-Articular? A Cadaveric Study
    McElvany, Matthew
    Benninger, Brion
    Smith, Sawyer
    Mirza, Amer
    Marshall, Lynn
    Friess, Darin
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (11) : e250 - e253
  • [14] Safe placement of proximal tibial transfixation wires with respect to intracapsular penetration
    Reid, JS
    Van Slyke, MA
    Moulton, MJR
    Mann, TA
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (01) : 10 - 17
  • [15] Septic arthritis of the major joints of the lower limb after periarticular external fixation application: are conventional safe corridors enough to prevent it?
    Stavlas, P
    Polyzois, D
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (02): : 239 - 247
  • [16] Stevens M A, 1995, Iowa Orthop J, V15, P217
  • [17] Szwedowski D., 2021, TRANSL RES ANAT, V23
  • [18] Extracapsular placement of distal tibial transfixation wires
    Vora, AM
    Haddad, SL
    Kadakia, A
    Lazarus, ML
    Merk, BR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05) : 988 - 993