Knee Capsule Anatomy: An MR Imaging and Cadaveric Study

被引:3
作者
Zibis, Aristeidis H. [1 ]
Vassalou, Evangelia E. [2 ,3 ]
Raoulis, Vasileios A. [1 ]
Lampridis, Vasileios [4 ]
Klontzas, Michail E. [2 ,5 ]
Fyllos, Apostolos [1 ]
Stavlas, Panagiotis [6 ]
Karantanas, Apostolos H. [2 ,5 ]
机构
[1] Univ Thessaly, Anat Lab, Dept Med, Sch Hlth Sci, 3 Univ Str, Biopolis 41110, Larissa, Greece
[2] Univ Hosp, Dept Med Imaging, Iraklion 71500, Greece
[3] Gen Hosp Sitia, Dept Med Imaging, Sitia 72300, Greece
[4] 424 Mil Gen Hosp, Dept Trauma & Orthopaed, Peripheriaki Odos Efkarpias, Thessaloniki 56429, Greece
[5] Univ Crete, Sch Med, Dept Radiol, Iraklion 71500, Greece
[6] Thriasio Gen Hosp, Dept Orthopaed, Athens 19600, Greece
关键词
external fixator; knee joint capsule; intra-capsular insertion; MR imaging/knee joint; MR arthrography; cadavers/knee joint; EXTRACAPSULAR PLACEMENT; EXTERNAL FIXATION; DISTAL; JOINT; PIN;
D O I
10.3390/diagnostics11111965
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This research focuses on the anatomical insertion of the synovial capsule around the knee. The attachments of the capsule were measured in 50 knee MR imaging studies with large intraarticular effusion. Corresponding measurements were performed in 20 fresh frozen cadaveric specimens, for validation. Femoral and tibial capsular reflections were defined as the distances between the attachment sites of the capsule and the femoral or tibial joint line and they were recorded in three coronal planes (anterior/middle/posterior). On MR imaging, the lateral/medial femoral capsular reflection mean values were 6.5/4.57 cm, 2.74/1.74 cm and 1.52/1.99 cm in the anterior, middle and posterior plane, respectively. MR imaging-based measurements did not differ significantly compared to corresponding cadaveric measurements. The mean values of the lateral/medial tibial capsular reflection on MR imaging were 0.09/0.11 cm, 0.34/0.26 cm and 0.62/0.34 cm in the anterior, middle and posterior plane, respectively. On cadaveric dissection, the maximum mean value was 1.45 cm, measured on the lateral side of the anterior plane. Apart from the lateral aspect of the posterior plane, MR imaging measurements were significantly lower, compared to the corresponding cadaveric measurements. The greatest femoral and tibial capsular reflections were found on the anterior and lateral side of the anterior plane. MR imaging appears to underestimate the distal extent of the knee capsule. Anatomical details of the knee capsule should be considered for safe insertion of external fixator pins.
引用
收藏
页数:10
相关论文
共 18 条
  • [1] Early outcome of hybrid external fixation for fracture of the distal tibia
    Anglen, JO
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (02) : 92 - 97
  • [2] ANATOMIC BASIS FOR IMPLANTATION OF THE ILIZAROV SYSTEM IN THE LEG
    BORRIONE, F
    JOUVE, JL
    LOUIS, R
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 1988, 10 (04) : 283 - 289
  • [3] Checketts RG, 1993, Int J Orthop Trauma Suppl, V3, P16, DOI [10.1007/978-1-4471-0691-311, DOI 10.1007/978-1-4471-0691-311]
  • [4] Safe extracapsular placement of proximal tibia transfixation pins
    DeCoster, TA
    Crawford, MK
    Kraut, MAS
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (04) : 236 - 240
  • [5] Infections in periarticular fractures of the lower extremity treated with tensioned wire hybrid fixators
    Hutson, JJ
    Zych, GA
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (03) : 214 - 218
  • [6] Anatomy of the distal knee joint and pyarthrosis following external fixation
    Hyman, J
    Moore, T
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (04) : 241 - 246
  • [7] Jelev L., 2021, TRANSL RES ANAT, V25
  • [8] Lateral femoral traction pin entry: risk to the femoral artery and other medial neurovascular structures
    Kwon, John Y.
    Johnson, Catherine E.
    Appleton, Paul
    Rodriguez, Edward K.
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2010, 5
  • [9] Cadaveric analysis of capsular attachments of the distal femur related to pin and wire placement
    Lowery, Kathryn
    Dearden, Paul
    Sherman, Kevin
    Mahadevan, Vishy
    Sharma, Hemant
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (06): : 970 - 974
  • [10] The adductor ratio: a new tool for joint line reconstruction in revision TKA
    Luyckx, T.
    Beckers, L.
    Colyn, W.
    Vandenneucker, H.
    Bellemans, J.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 3028 - 3033