Glucose biosensor based on the microcantilever

被引:251
作者
Pei, JH [1 ]
Tian, F [1 ]
Thundat, T [1 ]
机构
[1] Oak Ridge Natl Lab, Life Sci Div, Oak Ridge, TN 37831 USA
关键词
D O I
10.1021/ac035048k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Diagnosis and management of diabetes require quantitative and selective detection of blood glucose levels. We report a technique for micromechanical detection of biologically relevant glucose concentrations by immobilization of glucose oxidase (GOx) onto a microcantilever surface. Microfabricated cantilevers have traditionally found utility in atomic force microscope imaging. During the past decade, however; microcantilevers have been increasingly used as transducers in chemical-sensing systems. This paper describes the combination of this technology with enzyme specificity to construct a highly selective glucose biosensor. The enzyme-functionalized microcantilever undergoes bending due to a change in surface stress induced by the reaction between glucose in solution and the GOx immobilized on the cantilever surface. Experiments were carried out under flow conditions. The common interferences for glucose detection in other detection schemes have been tested and have shown to have no effect on the measurement of blood glucose level by this technique.
引用
收藏
页码:292 / 297
页数:6
相关论文
共 31 条
[1]   A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout [J].
Battiston, FM ;
Ramseyer, JP ;
Lang, HP ;
Baller, MK ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Güntherodt, HJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) :122-131
[2]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[3]  
CASS AEG, 1990, BIOSENSORS PRACTICAL, P15
[4]   Nanocantilever signal transduction by electron transfer [J].
Datskos, PG ;
Thundat, T .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2002, 2 (3-4) :369-373
[5]   USE OF POLYMER-FILMS IN AMPEROMETRIC BIOSENSORS [J].
EMR, SA ;
YACYNYCH, AM .
ELECTROANALYSIS, 1995, 7 (10) :913-923
[6]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[7]   DEVELOPMENT OF THE IMPLANTABLE GLUCOSE SENSOR - WHAT ARE THE PROSPECTS AND WHY IS IT TAKING SO LONG [J].
GOUGH, DA ;
ARMOUR, JC .
DIABETES, 1995, 44 (09) :1005-1009
[8]   Characterisation of an antibody coated microcantilever as a potential immuno-based biosensor [J].
Grogan, C ;
Raiteri, R ;
O'Connor, GM ;
Glynn, TJ ;
Cunningham, V ;
Kane, M ;
Charlton, M ;
Leech, D .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (03) :201-207
[9]   Cantilever-based optical deflection assay for discrimination of DNA single-nucleotide mismatches [J].
Hansen, KM ;
Ji, HF ;
Wu, GH ;
Datar, R ;
Cote, R ;
Majumdar, A ;
Thundat, T .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1567-1571
[10]  
Henry C, 1998, ANAL CHEM, V70, p594A