Renal function measurements from MR renography and a simplified multicompartmental model

被引:116
作者
Lee, Vivian S.
Rusinek, Henry
Bokacheva, Louisa
Huang, Ambrose J.
Oesingmann, Niels
Chen, Qun
Kaur, Manmeen
Prince, Keyma
Song, Ting
Kramer, Elissa L.
Leonard, Edward F.
机构
[1] NYU, Sch Med, Dept Radiol, New York, NY 10016 USA
[2] Columbia Univ, Dept Biomed Engn, New York, NY USA
[3] Columbia Univ, Dept Chem Engn, New York, NY USA
[4] Siemens Med Solut, Malvern, PA USA
关键词
multicompartmental modeling; magnetic resonance imaging; tracer kinetics; glomerular filtration rate; radionuclide scintigraphy; gadolinium chelates;
D O I
10.1152/ajprenal.00347.2006
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of this study was to determine the accuracy and sources of error in estimating single-kidney glomerular filtration rate (GFR) derived from low- dose gado-linium-enhanced T1- weighted MR renography. To analyze imaging data, MR signal intensity curves were converted to concentration vs. time curves, and a three- compartment, six- parameter model of the vascular- nephron system was used to analyze measured aortic, cortical, and medullary enhancement curves. Reliability of the parameter estimates was evaluated by sensitivity analysis and by Monte Carlo analyses of model solutions to which random noise had been added. The dominant sensitivity of the medullary enhancement curve to GFR 1 - 4 min after tracer injection was supported by a low coefficient of variation in model- fit GFR values ( 4%) when measured data were subjected to 5% noise. These analyses also showed the minimal effects of bolus dispersion in the aorta on parameter reliability. Single- kidney GFR from MR renography analyzed by the three-compartment model ( 4.0 - 71.4 ml/ min) agreed well with reference measurements from (99m)Tc-DTPA clearance and scintigraphy ( r = 0.84, P < 0.001). Bland-Altman analysis showed an average difference of 11.9 ml/ min ( 95% confidence interval = 5.8 - 17.9 ml/ min) between model and reference values. We conclude that a nephronbased multicompartmental model can be used to derive clinically useful estimates of single- kidney GFR from low- dose MR renography.
引用
收藏
页码:F1548 / F1559
页数:12
相关论文
共 38 条
[21]   Modeling regional myocardial flows from residue functions of an intravascular indicator [J].
Kroll, K ;
Wilke, N ;
JeroschHerold, M ;
Wang, Y ;
Zhang, Y ;
Bache, RJ ;
Bassingthwaighte, JB .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1996, 271 (04) :H1643-H1655
[22]   FUNCTIONAL-EVALUATION OF NORMAL AND ISCHEMIC KIDNEY BY MEANS OF GADOLINIUM-DOTA ENHANCED TURBOFLASH MR-IMAGING - A PRELIMINARY COMPARISON WITH TC-99M-MAG3 DYNAMIC SCINTIGRAPHY [J].
LAISSY, JP ;
FARAGGI, M ;
LEBTAHI, R ;
SOYER, P ;
BRILLET, G ;
MERY, JP ;
MENU, Y ;
LEGULUDEC, D .
MAGNETIC RESONANCE IMAGING, 1994, 12 (03) :413-419
[23]   Dynamic three-dimensional MR renography for the measurement of single kidney function: Initial experience [J].
Lee, VS ;
Rusinek, H ;
Noz, ME ;
Lee, P ;
Raghavan, M ;
Kramer, EL .
RADIOLOGY, 2003, 227 (01) :289-294
[24]   MR renography with low-dose gadopentetate dimeglumine: Feasibility [J].
Lee, VS ;
Rusinek, H ;
Johnson, G ;
Rofsky, NM ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 2001, 221 (02) :371-379
[25]   Renal artery stenosis: Functional assessment with dynamic MR perfusion measurements - Feasibility study [J].
Michaely, HJ ;
Schoenberg, SO ;
Oesingmann, N ;
Ittrich, C ;
Buhlig, C ;
Friedrich, D ;
Struwe, A ;
Rieger, J ;
Reininger, C ;
Samtleben, W ;
Weiss, M ;
Reiser, MF .
RADIOLOGY, 2006, 238 (02) :586-596
[26]   DETERMINATION OF SPLIT RENAL-FUNCTION FROM GAMMA-CAMERA RENOGRAPHY - A STUDY OF 3 METHODS [J].
MOONEN, M ;
JACOBSSON, L ;
GRANERUS, G ;
FRIBERG, P ;
VOLKMANN, R .
NUCLEAR MEDICINE COMMUNICATIONS, 1994, 15 (09) :704-711
[27]   A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION [J].
NELDER, JA ;
MEAD, R .
COMPUTER JOURNAL, 1965, 7 (04) :308-313
[28]   Rapid in vivo measurement of single-kidney extraction fraction and glomerular filtration rate with MR imaging [J].
Niendorf, ER ;
Grist, TM ;
Lee, FT ;
Brazy, PC ;
Santyr, GE .
RADIOLOGY, 1998, 206 (03) :791-798
[29]   Contrast-enhanced magnetic resonance angiography of cerebral arteries - A review [J].
Parker, DL ;
Tsuruda, JS ;
Goodrich, KC ;
Alexander, AL ;
Buswell, HR .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :560-572
[30]   QUANTITATIVE MORPHOLOGY OF THE RAT-KIDNEY [J].
PFALLER, W ;
RITTINGER, M .
INTERNATIONAL JOURNAL OF BIOCHEMISTRY, 1980, 12 (1-2) :17-22