Quantitative description of radiofrequency (RF) power-based ratiometric chemical exchange saturation transfer (CEST) pH imaging

被引:48
|
作者
Wu, Renhua [1 ]
Longo, Dario Livio [2 ]
Aime, Silvio [3 ]
Sun, Phillip Zhe [4 ,5 ]
机构
[1] Shantou Univ, Coll Med, Affiliated Hosp 2, Dept Radiol, Shantou, Peoples R China
[2] Univ Turin, Ctr Mol Biotechnol, Inst Biostruct & Bioimaging, CNR, Turin, Italy
[3] Univ Turin, Mol Imaging Ctr, Dept Mol Biotechnol & Hlth Sci, Turin, Italy
[4] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
[5] Harvard Univ, Sch Med, Boston, MA USA
基金
美国国家科学基金会;
关键词
chemical exchange saturation transfer (CEST); MRI; pH; quantitative CEST (qCEST) analysis; ratiometric CEST analysis; IN-VIVO; CONTRAST AGENT; MRI; TIME; IOPAMIDOL; QUESP; RATES; WATER;
D O I
10.1002/nbm.3284
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Chemical exchange saturation transfer (CEST) MRI holds great promise for the imaging of pH. However, routine CEST measurement varies not only with the pH-dependent chemical exchange rate, but also with CEST agent concentration, providing pH-weighted information. Conventional ratiometric CEST imaging normalizes the confounding concentration factor by analyzing the relative CEST effect from different exchangeable groups, requiring CEST agents with multiple chemically distinguishable labile proton sites. Recently, a radiofrequency (RF) power-based ratiometric CEST MRI approach has been developed for concentration-independent pH MRI using CEST agents with a single exchangeable group. To facilitate quantification and optimization of the new ratiometric analysis, we quantified the RF power-based ratiometric CEST ratio (rCESTR) and derived its signal-to-noise and contrast-to-noise ratios. Using creatine as a representative CEST agent containing a single exchangeable site, our study demonstrated that optimized RF power-based ratiometric analysis provides good pH sensitivity. We showed that rCESTR follows a base-catalyzed exchange relationship with pH independent of creatine concentration. The pH accuracy of RF power-based ratiometric MRI was within 0.15-0.20 pH units. Furthermore, the absolute exchange rate can be obtained from the proposed ratiometric analysis. To summarize, RF power-based ratiometric CEST analysis provides concentration-independent pH-sensitive imaging and complements conventional multiple labile proton group-based ratiometric CEST analysis. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:555 / 565
页数:11
相关论文
共 50 条
  • [31] Quantitative chemical exchange saturation transfer with hyperpolarized nuclei (qHyper-CEST): Sensing xenon-host exchange dynamics and binding affinities by NMR
    Kunth, M.
    Witte, C.
    Schroeder, L.
    JOURNAL OF CHEMICAL PHYSICS, 2014, 141 (19)
  • [32] Imaging chemical exchange saturation transfer (CEST) effects following tumor-selective acidification using lonidamine
    McVicar, Nevin
    Li, Alex X.
    Meakin, Susan O.
    Bartha, Robert
    NMR IN BIOMEDICINE, 2015, 28 (05) : 566 - 575
  • [33] Investigation of optimizing and translating pH-sensitive pulsed-chemical exchange saturation transfer (CEST) imaging to a 3T clinical scanner
    Sun, Phillip Zhe
    Benner, Thomas
    Kumar, Ashok
    Sorensen, A. Gregory
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (04) : 834 - 841
  • [34] A lanthanide complex with dual biosensing properties: CEST (chemical exchange saturation transfer) and BIRDS (biosensor imaging of redundant deviation in shifts) with europium DOTA-tetraglycinate
    Coman, Daniel
    Kiefer, Garry E.
    Rothman, Douglas L.
    Sherry, A. Dean
    Hyder, Fahmeed
    NMR IN BIOMEDICINE, 2011, 24 (10) : 1216 - 1225
  • [35] Development of a Nanoscale Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agent That Measures pH
    Kombala, Chathuri J.
    Kotrotsou, Aikaterini
    Schuler, F. William
    de la Cerda, Jorge
    Ma, Jacqueline C.
    Zhang, Shu
    Pagel, Mark D.
    ACS NANO, 2021, 15 (12) : 20678 - 20688
  • [36] Imaging In Vivo Extracellular pH with a Single Paramagnetic Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agent
    Liu, Guanshu
    Li, Yuguo
    Sheth, Vipul R.
    Pagel, Mark D.
    MOLECULAR IMAGING, 2012, 11 (01): : 47 - 57
  • [37] Hydrazo-CEST: Hydrazone-Dependent Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agents
    Dang, Trina
    Suchy, Mojmir
    Truong, Yen J.
    Oakden, Wendy
    Lam, Wilfred W.
    Lazurko, Caitlin
    Facey, Glenn
    Stanisz, Greg J.
    Shuhendler, Adam J.
    CHEMISTRY-A EUROPEAN JOURNAL, 2018, 24 (36) : 9148 - 9156
  • [38] A New Contrast in MR Mammography by Means of Chemical Exchange Saturation Transfer (CEST) Imaging at 3 Tesla: Preliminary Results
    Schmitt, B.
    Zamecnik, P.
    Zaiss, M.
    Rerich, E.
    Schuster, L.
    Bachert, P.
    Schlemmer, H. -P.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (11): : 1030 - 1036
  • [39] Two point Dixon-based chemical exchange saturation transfer (CEST) MRI in renal transplant patients on 3 T
    Stabinska, Julia
    Mueller-Lutz, Anja
    Wittsack, Hans-Jorg
    Tell, Christian
    Rump, Lars Christian
    Ertas, Neslihan
    Antoch, Gerald
    Ljimani, Alexandra
    MAGNETIC RESONANCE IMAGING, 2022, 90 : 61 - 69
  • [40] Relaxation-compensated CEST (chemical exchange saturation transfer) imaging in breast cancer diagnostics at 7T
    Loi, Lisa
    Zimmermann, Ferdinand
    Goerke, Steffen
    Korzowski, Andreas
    Meissner, Jan-Eric
    Deike-Hofmann, Katerina
    Stieber, Anne
    Bachert, Peter
    Ladd, Mark Edward
    Schlemmer, Heinz-Peter
    Bickelhaupt, Sebastian
    Schott, Sarah
    Paech, Daniel
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129