Polymers for Neural Implants

被引:359
作者
Hassler, Christina [1 ,2 ]
Boretius, Tim [1 ]
Stieglitz, Thomas [1 ,2 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn IMTEK, Lab Biomed Microtechnol, Freiburg, Germany
[2] Bernstein Ctr Freiburg, Freiburg, Germany
关键词
biocompatibility; biomaterials; polyimides; silicones; thin-films; ANTERIOR ROOT STIMULATORS; VAGAL NERVE-STIMULATION; NEUROLOGICAL PROSTHESES; ELECTRICAL-STIMULATION; SILICONE-RUBBER; MICROELECTRODE ARRAY; MULTIELECTRODE ARRAY; RETINAL PROSTHESIS; COCHLEAR IMPLANT; ELECTRODE ARRAYS;
D O I
10.1002/polb.22169
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Neural implants are technical systems that restore sensory or motor functions after injury and modulate neural behavior in neuronal diseases. Neural interfaces or prostheses have lead to new therapeutic options and rehabilitation approaches in the last 40 years. The interface between the nervous tissue and the technical material is the place that determines success or failure of the neural implant. Recording of nerve signals and stimulation of nerve cells take place at this neuro-technical interface. Polymers are the most common material class for substrate and insulation materials in combination with metals for interconnection wires and electrode sites. This work focuses on the neuro-technical interface and summarizes its fundamental specifications first. The most common polymer materials are presented and described in detail. We conclude with an overview of the different applications and their specific designs with the accompanying manufacturing processes from precision mechanics, laser structuring and micromachining that are introduced in either the peripheral or central nervous system. (C) 2010 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 49: 18-33, 2011
引用
收藏
页码:18 / 33
页数:16
相关论文
共 145 条
[1]  
Agarwal S, 2003, J REHABIL RES DEV, V40, P241
[2]   Deep brain stimulation, vagal nerve stimulation and transcranial stimulation: An overview of stimulation parameters and neurotransmitter release [J].
Albert, G. C. ;
Cook, C. M. ;
Prato, F. S. ;
Thomas, A. W. .
NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 2009, 33 (07) :1042-1060
[3]   VISUAL SENSATIONS PRODUCED BY INTRACORTICAL MICROSTIMULATION OF THE HUMAN OCCIPITAL CORTEX [J].
BAK, M ;
GIRVIN, JP ;
HAMBRECHT, FT ;
KUFTA, CV ;
LOEB, GE ;
SCHMIDT, EM .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (03) :257-259
[4]   Single-mode TE00-TM00 optical waveguides on SU-8 polymer [J].
Bêche, B ;
Pelletier, N ;
Gaviot, E ;
Zyss, J .
OPTICS COMMUNICATIONS, 2004, 230 (1-3) :91-94
[5]  
BORETIUS T, 2010, ARTIF ORGANS, V34, pA43
[6]   A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve [J].
Boretius, Tim ;
Badia, Jordi ;
Pascual-Font, Aran ;
Schuettler, Martin ;
Navarro, Xavier ;
Yoshida, Ken ;
Stieglitz, Thomas .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (01) :62-69
[7]  
BRINDLEY G S, 1972, Journal of Physiology (Cambridge), V222, P135
[8]   SENSATIONS PRODUCED BY ELECTRICAL STIMULATION OF VISUAL CORTEX [J].
BRINDLEY, GS ;
LEWIN, WS .
JOURNAL OF PHYSIOLOGY-LONDON, 1968, 196 (02) :479-&
[9]   THE FIRST 500 SACRAL ANTERIOR ROOT STIMULATORS - IMPLANT FAILURES AND THEIR REPAIR [J].
BRINDLEY, GS .
PARAPLEGIA, 1995, 33 (01) :5-9
[10]   THE FIRST 500 PATIENTS WITH SACRAL ANTERIOR ROOT STIMULATOR IMPLANTS - GENERAL DESCRIPTION [J].
BRINDLEY, GS .
PARAPLEGIA, 1994, 32 (12) :795-805