Geometric Calibration of an OCT Imaging System

被引:0
|
作者
Ourak, M. [1 ]
Tamadazte, B. [1 ]
Laurent, G. J. [1 ]
Andreff, N. [1 ]
机构
[1] Univ Bourgogne Franche Comte, CNRS, ENSMM, FEMTO ST Inst,Dept AS2M, F-25000 Besancon, France
来源
2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA) | 2018年
关键词
OPTICAL COHERENCE TOMOGRAPHY; DISTORTIONS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper deals with an OCT (optical coherence tomography) geometric calibration method. OCT medical imaging system has received a growing interest during the last two decades. In medical purposes, OCT images are generally called optical biopsies which allows in-vivo investigation almost similar to a histopathological study. The physician can rely on the OCT images to establish a rapid and direct diagnosis. But the OCT images formation suffered numerous distortions due in particular to the optical path, from the source to the viewed sample passing through the two reflecting mirrors and a scan objective. The obtained optical biopsies include several spectral and geometric distortions. The proposed calibration model aims to compensate the geometrical ones. More precisely, two models were developed allowing the correction of both 2D images (B-Scan slices) and 3D images (volume). These models were experimentally validated (in both artificial and biological samples) using a spectral domain OCT system. It has demonstrated a significant enhancement of the OCT images accuracy.
引用
收藏
页码:3993 / 3999
页数:7
相关论文
共 50 条
  • [1] Geometric calibration of a hyperspectral imaging system
    Spiclin, Ziga
    Katrasnik, Jaka
    Burmen, Miran
    Pernus, Franjo
    Likar, Bostjan
    APPLIED OPTICS, 2010, 49 (15) : 2813 - 2818
  • [2] Geometric calibration for a SPECT system dedicated to breast imaging
    武丽伟
    曹学香
    王璐
    黄先超
    柴培
    贠明凯
    张玉包
    张龙
    单保慈
    魏龙
    Chinese Physics C, 2012, 36 (10) : 1019 - 1024
  • [3] Geometric calibration for a SPECT system dedicated to breast imaging
    Wu Li-Wei
    Cao Xue-Xiang
    Wang Lu
    Huang Xian-Chao
    Chai Pei
    Yun Ming-Kai
    Zhang Yu-Bao
    Zhang Long
    Shan Bao-Ci
    Wei Long
    CHINESE PHYSICS C, 2012, 36 (10) : 1019 - 1024
  • [4] Geometric calibration for a SPECT system dedicated to breast imaging
    武丽伟
    曹学香
    王璐
    黄先超
    柴培
    贠明凯
    张玉包
    张龙
    单保慈
    魏龙
    Chinese Physics C, 2012, (10) : 1019 - 1024
  • [5] GEOMETRIC MODELLING AND CALIBRATION OF A SPHERICAL CAMERA IMAGING SYSTEM
    Lichti, Derek D.
    Jarron, David
    Tredoux, Wynand
    Shahbazi, Mozhdeh
    Radovanovic, Robert
    PHOTOGRAMMETRIC RECORD, 2020, 35 (170): : 123 - 142
  • [6] Post-launch geometric calibration of linear array imaging system
    Zhou, GQ
    Baysal, O
    RAST 2003: RECENT ADVANCES IN SPACE TECHNOLOGIES, PROCEEDINGS, 2003, : 325 - 330
  • [7] Geometric Calibration of a Micro-CT System and Performance for Insect Imaging
    Hu, Zhanli
    Gui, Jianbao
    Zou, Jing
    Rong, Junyan
    Zhang, Qiyang
    Zheng, Hairong
    Xia, Dan
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (04): : 655 - 660
  • [8] Online Geometric Calibration of a Hybrid CT System for Ultrahigh-Resolution Imaging
    King, Dakota H.
    Wang, Muyang
    Bennett, Eric E.
    Mazilu, Dumitru
    Chen, Marcus Y.
    Wen, Han
    TOMOGRAPHY, 2022, 8 (05) : 2547 - 2555
  • [9] Group geometric calibration and rectification for circular multi-camera imaging system
    Abedi, Firas
    Yang, You
    Liu, Qiong
    OPTICS EXPRESS, 2018, 26 (23): : 30596 - 30613
  • [10] Camera calibration with a near-parallel imaging system based on geometric moments
    Li, JunLan
    Zhang, DaWei
    OPTICAL ENGINEERING, 2011, 50 (02)