Radiation dose efficiency of multi-energy photon-counting-detector CT for dual-contrast imaging

被引:30
作者
Ren, Liqiang [1 ]
Rajendran, Kishore [1 ]
McCollough, Cynthia H. [1 ]
Yu, Lifeng [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 1st St SW, Rochester, MN 55902 USA
基金
美国国家卫生研究院;
关键词
multi-energy CT; photon-counting-detector CT; single-energy CT; material decomposition; radiation dose efficiency; COMPUTED-TOMOGRAPHY; ENERGY CT; IODINE; QUANTIFICATION; AGENTS;
D O I
10.1088/1361-6560/ab55bf
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Compared to traditional multi-scan single-energy CT (SECT), one potential advantage of single-scan multi-energy CT (MECT) proposed for simultaneous imaging of multiple contrast agents is the radiation dose reduction. This phantom study aims to rigorously evaluate whether the radiation dose can truly be reduced in a single-scan MECT protocol (MECT_1s) in biphasic liver imaging with iodine and gadolinium, and small bowel imaging with iodine and bismuth, compared to traditional two-scan SECT protocols (SECT_2s). For MECT_1s, mixed iodine/gadolinium samples were prepared corresponding to late arterial/portal-venous phase for biphasic liver imaging. Mixed iodine/bismuth samples were prepared representing the arterial/enteric enhancement for small bowel imaging. For SECT_2s, separate contrast samples were prepared to mimic separate scans in arterial/venous phase and arterial/enteric enhancement. Samples were placed in a 35 cm wide water phantom and scanned by a research whole-body photon-counting-detector-CT (PCDCT) system ('chess' mode). MECT images were acquired with optimized kV/threshold settings for each imaging task, and SECT images were acquired at 120 kV. Total CTDIvol was matched for the two protocols. Image-based three-material decomposition was employed in MECT_1s to determine the basis material concentration values, which were converted to CT numbers at 120 kV (i.e. virtual SECT images) to compare with the SECT images directly acquired with SECT_2s. The noise difference between the SECT and the virtual SECT images was compared to evaluate the dose efficiency of MECT_1s. Compared to SECT_2s, MECT_1s was not dose efficient for both imaging tasks. The amount of noise increase is highly task dependent, with noise increased by 203%/278% and 110%/82% in virtual SECT images for iodine/gadolinium and iodine/bismuth quantifications, respectively, corresponding to dose increase by 819%/1328% and 340%/230% in MECT_1s to achieve the same image noise level. MECT with the current PCD-CT technique requires higher radiation dose than SECT to achieve the same image quality.
引用
收藏
页数:13
相关论文
共 37 条
[1]   Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE [J].
Anderson, N. G. ;
Butler, A. P. ;
Scott, N. J. A. ;
Cook, N. J. ;
Butzer, J. S. ;
Schleich, N. ;
Firsching, M. ;
Grasset, R. ;
de Ruiter, N. ;
Campbell, M. ;
Butler, P. H. .
EUROPEAN RADIOLOGY, 2010, 20 (09) :2126-2134
[2]   Multicolor spectral photon-counting computed tomography: in vivo dual contrast imaging with a high count rate scanner [J].
Cormode, David P. ;
Si-Mohamed, Salim ;
Bar-Ness, Daniel ;
Sigovan, Monica ;
Naha, Pratap C. ;
Balegamire, Joelle ;
Lavenne, Franck ;
Coulon, Philippe ;
Roessl, Ewald ;
Bartels, Matthias ;
Rokni, Michal ;
Blevis, Ira ;
Boussel, Loic ;
Douek, Philippe .
SCIENTIFIC REPORTS, 2017, 7
[3]   Experimental feasibility of spectral photon-counting computed tomography with two contrast agents for the detection of endoleaks following endovascular aortic repair [J].
Dangelmaier, Julia ;
Bar-Ness, Daniel ;
Daerr, Heiner ;
Muenzel, Daniela ;
Si-Mohamed, Salim ;
Ehn, Sebastian ;
Fingerle, Alexander A. ;
Kimm, Melanie A. ;
Kopp, Felix K. ;
Boussel, Loic ;
Roessl, Ewald ;
Pfeiffer, Franz ;
Rummeny, Ernst J. ;
Proksa, Roland ;
Douek, Philippe ;
Noel, Peter B. .
EUROPEAN RADIOLOGY, 2018, 28 (08) :3318-3325
[4]   Performance of today's dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study [J].
Faby, Sebastian ;
Kuchenbecker, Stefan ;
Sawall, Stefan ;
Simons, David ;
Schlemmer, Heinz-Peter ;
Lell, Michael ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2015, 42 (07) :4349-4366
[5]   Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies [J].
Gutjahr, Ralf ;
Halaweish, Ahmed F. ;
Yu, Zhicong ;
Leng, Shuai ;
Yu, Lifeng ;
Li, Zhoubo ;
Jorgensen, Steven M. ;
Ritman, Erik L. ;
Kappler, Steffen ;
McCollough, Cynthia H. .
INVESTIGATIVE RADIOLOGY, 2016, 51 (07) :421-429
[6]  
KELCZ F, 1979, Medical Physics (Woodbury), V6, P418, DOI 10.1118/1.594520
[7]   Gadolinium deposition and the potential for toxicological sequelae - A literature review of issues surrounding gadolinium-based contrast agents [J].
Layne, Kerry A. ;
Dargan, Paul I. ;
Archer, John R. H. ;
Wood, David M. .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2018, 84 (11) :2522-2534
[8]   150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology Technical Performance and First Patient Images [J].
Leng, Shuai ;
Rajendran, Kishore ;
Gong, Hao ;
Zhou, Wei ;
Halaweish, Ahmed F. ;
Henning, Andre ;
Kappler, Steffen ;
Baer, Matthias ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
INVESTIGATIVE RADIOLOGY, 2018, 53 (11) :655-662
[9]   Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system [J].
Leng, Shuai ;
Yu, Zhicong ;
Halaweish, Ahmed ;
Kappler, Steffen ;
Hahn, Katharina ;
Henning, Andre ;
Li, Zhoubo ;
Lane, John ;
Levin, David L. ;
Jorgensen, Steven ;
Ritman, Erik ;
McCollough, Cynthia .
JOURNAL OF MEDICAL IMAGING, 2016, 3 (04)
[10]   Estimation of signal and noise for a whole-body research photon-counting CT system [J].
Li, Zhoubo ;
Leng, Shuai ;
Yu, Zhicong ;
Kappler, Steffen ;
McCollough, Cynthia H. .
Journal of Medical Imaging, 2017, 4 (02)