Method Development and Validation of a New Stability Indicating Reverse Phase Ultra-fast Liquid Chromatographic Method for the Determination of Gefitinib (Anticancer Agent) in the Presence of an Internal Standard

被引:0
|
作者
Kulkarni, Dipak Chandrakant [1 ]
Dadhich, Anima Sunil [1 ]
Annapurna, Mukthinuthalapati Mathrusri [2 ]
机构
[1] Gandhi Inst Technol & Management Deemed Univ, Gandhi Inst Technol & Management, Inst Sci, Dept Chem, Visakhapatnam, Andhra Pradesh, India
[2] Gandhi Inst Technol & Management Deemed Univ, Gandhi Inst Technol & Management, Inst Pharm, Visakhapatnam, Andhra Pradesh, India
关键词
Gefitinib; International Council for Harmonisation guidelines; reverse phase ultra-fast liquid chromatographic; stability indicating; stress degradation studies; Trifluridine (internal standard); validation; MOUSE PLASMA;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Y Introduction: A new stability indicating reverse phase ultra-fast liquid chromatographic (UFLC) method has been developed and validated for the quantification of Gefitinib in pharmaceutical formulations, that is, tablets in presence of an internal standard, Trifluridine. Gefitinib is an anticancer drug and it is used for the treatment of lung cancer, prostate cancer, and breast cancer. Materials and Methods: A mixture of tetra butyl ammonium hydrogen sulfate:methanol:Acetic acid (55:45:0.1) (pH 3.4) was used as the mobile phase for the chromatographic study (Flow rate: 0.8 mL/min; ultraviolet detection: 264 nm; Injection volume: 20 mu l). Shimadzu Model CBM-20A/20 Alite UFLC system with Agilent C-18 column and photodiode-array detection detector was used for the present study. Results and Discussion: Gefitinib has shown linearity over the concentration range 0.5-100 mu g/ml with linear regression equation, y = 0.1027x + 0.0022 (R-2 = 0.9999). The limit of detection and limit of quantitation were found to be 0.1392 mu g/ml and 0.4269 mu g/ml, respectively. Stress degradation studies were performed by treating Gefitinib with different stress conditions, and the method was validated as per the International Council for Harmonisation guidelines.
引用
收藏
页码:478 / 487
页数:10
相关论文
共 50 条
  • [1] New Stability Indicating Liquid Chromatographic Method for the Determination of Eplerenone in the Presence of Internal Standard
    Annapurna, Mukthinuthalapati Mathrusri
    Madhuri, Vasantham Lakshmi
    Valli, Duvvi Sri
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (01) : S189 - S194
  • [2] Analytical lifecycle management oriented development and validation of a new stability-indicating ultra-fast liquid chromatographic method: case study of Glycopyrrolate
    Panda, Sagar Suman
    Kumar, B. V. V. Ravi
    Swain, Suchismita
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 56
  • [3] DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING ULTRA-FAST LIQUID CHROMATOGRAPHIC ANALYSIS FOR THE SIMULTANEOUS DETERMINATION OF FENTICONAZOLE AND ITS RELATED SUBSTANCES IN PHARMACEUTICAL FORMULATIONS
    Onal, Cem
    Binay, Emrullah
    Onal, Armagan
    REVUE ROUMAINE DE CHIMIE, 2020, 65 (02) : 201 - 209
  • [4] Development of a Validated Stability Indicating Liquid Chromatographic Method for the Determination of Pterostilbene
    Annapurna, Mukthinuthalapati Mathrusri
    Venkatesh, Bukkapatnam
    Teja, Gunnam Ravi
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2018, 52 (04) : S63 - S70
  • [5] Development and Validation of a Stability Indicating Liquid Chromatographic Method for the Determination of Milnacipran in Bulk and its Formulations
    Singhvi, Gautam
    Gampa, Gautham
    Saha, Ranendra N.
    CURRENT PHARMACEUTICAL ANALYSIS, 2013, 9 (02) : 191 - 198
  • [6] Development and validation of stability indicating chromatographic method for determination of impurities in maprotiline pharmaceutical tablets
    Duric, Svetlana Lj.
    Naskovic, Daniela C.
    Velickovic, Dragan T.
    Milenovic, Dragan M.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (02) : 225 - 233
  • [7] Development and validation of stability indicating chromatographic method for determination of impurities in maprotiline pharmaceutical tablets
    Svetlana Lj. Đurić
    Daniela Č. Nasković
    Dragan T. Veličković
    Dragan M. Milenović
    Journal of Analytical Chemistry, 2015, 70 : 225 - 233
  • [8] Development and validation of a stability-indicating reverse phase ultra performance liquid chromatographic method for the estimation of nebivolol impurities in active pharmaceutical ingredients and pharmaceutical formulation
    Thuivimala, Veera Raghava Raju
    Lana, Mohana Krishnaa
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (10) : 1051 - 1058
  • [9] DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING REVERSED PHASE ULTRA PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR THE QUANTITATIVE ANALYSIS OF RALOXIFENE HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORM
    Saini, Deepa
    Baboota, Sanjula
    Ali, Mushir
    Patel, Harilal
    Jain, Pankaj
    Neerumulla, Sudhakar
    Ali, Javed
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (1-4) : 162 - 173
  • [10] New Stability Indicating Ultrafast Liquid Chromatographic Method for the Determination of Sofosbuvir in Tablets
    Annapurna, Mukthinuthalapati Mathrusri
    Teja, Gunnam Ravi
    Chaitanya, Sunkara Mrunal
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (01) : S151 - S158