Transient analysis of aerial multi-conductor transmission lines with branch

被引:17
|
作者
Lu, TB [1 ]
Cui, X [1 ]
Li, L [1 ]
机构
[1] N China Elect Power Univ, Dept Elect Engn, Baoding 071003, Hebei, Peoples R China
关键词
FDTD; MTLs; substation; wave propagation;
D O I
10.1109/20.952599
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to analyze the switching transient electromagnetic field generated by the aerial busbars in substation, the transient wave process of the lossy aerial multi-conductor transmission lines (MTLs) with branch is calculated by using the finite-difference time-domain (FDTD) method. Based on the Pade approximation and on Prony's method, the iterative equations of the lossy aerial MTLs with branch are presented in this paper. An aerial busbars model in a 500 kV substation is analyzed when circuit breakers and disconnect switches are closed. The results can be used to research the immunity of the control devices in the substation.
引用
收藏
页码:3298 / 3302
页数:5
相关论文
共 50 条
  • [31] Transient Analysis of the Multi-Conductor Transmission Line Based on Matrix Form of T Type Leapfrog Scheme
    Wang, Tian-Hao
    Gao, Yin-Han
    Gao, Le
    Liu, Chang-Ying
    An, Zhan-Yang
    Jin, Yu
    Chu, Xin-Ze
    JOURNAL OF COMPUTATIONAL AND THEORETICAL NANOSCIENCE, 2015, 12 (09) : 2982 - 2989
  • [32] MATRIX ANALYSIS OF PULSE WAVE PROPAGATION ON MULTI-CONDUCTOR TRANSMISSION SYSTEM
    鲍城志
    Science China Mathematics, 1963, (02) : 245 - 270
  • [33] Reluctance Network Method for Calculating the Series Impedance Matrix of Multi-Conductor Transmission Lines
    Bormann, Dierk
    Tavakoli, Hanif
    IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (10) : 5270 - 5279
  • [34] MATRIX ANALYSIS OF PULSE WAVE PROPAGATION ON MULTI-CONDUCTOR TRANSMISSION SYSTEM
    BOW, ST
    SCIENTIA SINICA, 1963, 12 (02): : 246 - &
  • [35] CHARACTERISTICS OF MULTI-CONDUCTOR, ASYMMETRIC, SLOW-WAVE MICROSTRIP TRANSMISSION-LINES
    MU, TC
    OGAWA, H
    ITOH, T
    MICROWAVE JOURNAL, 1986, 29 (05) : 108 - 108
  • [36] SPICE model composed of exact poles and residues of multi-conductor lossy transmission lines
    Tanji, Y
    ELECTRICAL PERFORMANCE OF ELECTRONIC PACKAGING, 2002, : 293 - 296
  • [37] Attachable Transient Model and Its Modular Packaging of Transformer Winding Multi-conductor Transmission Lines with External Distributed Parameter Components
    Peng L.
    Cheng Y.
    Zheng D.
    Chang W.
    Bi J.
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (10): : 3955 - 3967
  • [38] Thermal analysis for multi-conductor bundle in high voltage overhead transmission lines under the effect of strong wind
    Yang, Wentao
    Zheng, Zhi
    Huang, Wei
    Chen, Danhua
    Yuan, Jie
    Yue, Yishi
    Sun, Zezhong
    Sun, Qiuqin
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 231
  • [39] Alternative Modal Analysis of N-coupled Multi-conductor Power Lines
    Brandao Faria, Jose A.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (19) : 2237 - 2242