Free-running ADC- and FPGA-based signal processing method for brain PET using GAPD arrays

被引:25
作者
Hu, Wei [1 ,2 ]
Choi, Yong [1 ]
Hong, Key Jo [1 ]
Rang, Jihoon [1 ,2 ]
Jung, Jin Ho [1 ]
Huh, Youn Sul [1 ,2 ]
Lim, Hyun Keong [1 ]
Kim, Sang Su [1 ]
Kim, Byung-Tae [2 ]
Chung, Yonghyun [3 ]
机构
[1] Sogang Univ, Dept Elect Engn, Seoul 121742, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Nucl Med, Seoul 135710, South Korea
[3] Yonsei Univ, Coll Hlth Sci, Dept Radiol Sci, Heungup Wonju 220710, Kangwon Do, South Korea
基金
新加坡国家研究基金会;
关键词
Positron emission tomography; Gamma ray signal processing; Field-programmable gate array (FPGA); Data acquisition (DAQ); Analog-to-digital converter (ADC); Geiger mode avalanche photodiodes (GAPDs); FRONT-END ELECTRONICS; RESOLUTION; SYSTEM;
D O I
10.1016/j.nima.2011.05.053
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Currently, for most photomultiplier tube (PMT)-based PET systems, constant fraction discriminators (CFD) and time to digital converters (TDC) have been employed to detect gamma ray signal arrival time, whereas anger logic circuits and peak detection analog-to-digital converters (ADCs) have been implemented to acquire position and energy information of detected events. As compared to PMT the Geiger-mode avalanche photodiodes (GAPDs) have a variety of advantages, such as compactness, low bias voltage requirement and MRI compatibility. Furthermore, the individual read-out method using a GAPD array coupled 1:1 with an array scintillator can provide better image uniformity than can be achieved using PMT and anger logic circuits. Recently, a brain PET using 72 GAPD arrays (4 x 4 array, pixel size: 3 mm x 3 mm) coupled 1:1 with LYSO scintillators (4 x 4 array, pixel size: 3 mm x 3 mm x 20 mm) has been developed for simultaneous PET/MRI imaging in our laboratory. Eighteen 64:1 position decoder circuits (PDCs) were used to reduce GAPD channel number and three off-the-shelf free-running ADC and field programmable gate array (FPGA) combined data acquisition (DAQ) cards were used for data acquisition and processing. In this study, a free-running ADC- and FPGA-based signal processing method was developed for the detection of gamma ray signal arrival time, energy and position information all together for each GAPD channel. For the method developed herein, three DAQ cards continuously acquired 18 channels of pre-amplified analog gamma ray signals and 108-bit digital addresses from 18 PDCs. In the FPGA, the digitized gamma ray pulses and digital addresses were processed to generate data packages containing pulse arrival time, baseline value, energy value and GAPD channel ID. Finally, these data packages were saved to a 128 Mbyte on-board synchronous dynamic random access memory (SDRAM) and then transferred to a host computer for coincidence sorting and image reconstruction. In order to evaluate the functionality of the developed signal processing method, energy and timing resolutions for brain PET were measured via the placement of a 6 mu Ci Na-22 point source at the center of the PET scanner. Furthermore the PET image of the hot rod phantom (rod diameter: from 2.5 mm to 6.5 mm) with activity of 1 mCi was simulated, and then image acquisition experiment was performed using the brain PET. Measured average energy resolution for 1152 GAPD channels and system timing resolution were 19.5% (FWHM%) and 2.7 ns (FWHM), respectively. With regard to the acquisition of the hot rod phantom image, rods could be resolved down to a diameter of 2.5 mm, which was similar to simulated results. The experimental results demonstrated that the signal processing method developed herein was successfully implemented for brain PET. This reduced the complexity, cost and developing duration for PET system relative to normal PET electronics, and it will obviously be useful for the development of high-performance investigational PET systems. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:370 / 375
页数:6
相关论文
共 25 条
[1]   A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY [J].
CASEY, ME ;
NUTT, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :460-463
[2]  
Cherry S.R., 2002, PHYS NUCL MED
[3]   USE OF DIGITAL FRONT-END ELECTRONICS FOR OPTIMIZATION OF A MODULAR PET DETECTOR [J].
CUTLER, PD ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :408-418
[4]   FPGA Electronics for OPET: A Dual-Modality Optical and Positron Emission Tomograph [J].
Douraghy, Ali ;
Rannou, Fernando R. ;
Silverman, Robert W. ;
Chatziioannou, Arion F. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) :2541-2545
[5]   Time resolution studies using digital constant fraction discrimination [J].
Fallu-Labruyere, A. ;
Tan, H. ;
Hennig, W. ;
Warburton, W. K. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01) :247-251
[6]   Real time digital signal processing implementation for an APD-based PET scanner with phoswich detectors [J].
Fontaine, R. ;
Tetrault, M. -A. ;
Belanger, F. ;
Viscogliosi, N. ;
Himmich, R. ;
Michaud, J. -B. ;
Robert, S. ;
Leroux, J. -D. ;
Semmaoui, H. ;
Berard, P. ;
Cadorette, J. ;
Pepin, C. M. ;
Lecomte, R. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) :784-788
[7]   New embedded digital front-end for high resolution PET scanner [J].
Guerra, P. ;
Espinosa, J. ;
Ortuno, J. E. ;
Kontaxakis, G. ;
Vaquero, J. J. ;
Desco, M. ;
Santos, A. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) :770-775
[8]   A simple and improved digital timing method for positron emission tomography [J].
Hu, Wei ;
Choi, Yong ;
Hong, Key Jo ;
Kang, Jihoon ;
Jung, Jin Ho ;
Huh, Youn Suk ;
Lim, Hyun Keong ;
Kim, Sang Su ;
Min, Byung Jun ;
Kim, Byung-Tae .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01) :219-224
[9]   Development of an FPGA-based data acquisition module for small animal PET [J].
Imrek, J. ;
Novak, D. ;
Hegyesi, Gy. ;
Kalinka, G. ;
Molnar, J. ;
Vegh, J. ;
Balkay, L. ;
Emri, M. ;
Molnar, G. ;
Tron, L. ;
Bagamery, I. ;
Bukki, T. ;
Rozsa, S. ;
Szabo, Zs. ;
Kerek, A. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) :2698-2703
[10]   Development of a position decoder circuit for PET consisting of GAPD arrays [J].
Jung, Jin Ho ;
Choi, Yong ;
Hong, Key Jo ;
Hu, Wei ;
Kang, Ji Hoon ;
Min, Byung Jun ;
Shin, Seung Han ;
Lim, Hyun Keong ;
Huh, Yoon Suk ;
Kim, Eun-Jeong .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3) :310-315