Local impedance measurements during contact force-guided cavotricuspid isthmus ablation for predicting an effective radiofrequency ablation

被引:3
作者
Sasaki, Takehito [1 ]
Nakamura, Kohki [1 ]
Minami, Kentaro [1 ]
Take, Yutaka [1 ]
Nakatani, Yosuke [1 ]
Miki, Yuko [1 ]
Goto, Koji [1 ]
Kaseno, Kenichi [1 ]
Yamashita, Eiji [1 ]
Koyama, Keiko [2 ]
Naito, Shigeto [1 ]
机构
[1] Gunma Prefectural Cardiovasc Ctr, Div Cardiol, 3-12 Kameizumi Machi, Maebashi, Gumma 3710004, Japan
[2] Gunma Prefectural Cardiovasc Ctr, Div Radiol, Maebashi, Gumma, Japan
关键词
atrial flutter; cavotricuspid isthmus; contact force; local impedance; radiofrequency catheter ablation; INDEX;
D O I
10.1002/joa3.12680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: An ablation catheter capable of contact force (CF) and local impedance (LI) monitoring (IntellaNav StablePoint, Boston Scientific) has been recently launched. We evaluated the relationship between the CF and LI values during radiofrequency catheter ablation (RFCA) along the cavotricuspid isthmus (CTI). Methods: Fifty consecutive subjects who underwent a CTI-RFCA using IntellaNav StablePoint catheters were retrospectively studied. The initial CF and LI at the start of the RF applications and mean CF and minimum LI during the RF applications were measured. The absolute and percentage LI drops were calculated as the difference between the initial and minimum LIs and 100 x absolute LI drop/initial LI, respectively. Results: We analyzed 602 first-pass RF applications. A weak correlation was observed between the initial CF and LI (r = 0.13) and between the mean CF and LI drops (r = 0.22). The initial LI and absolute and percentage LI drops were greater at effective ablation sites than ineffective ablation sites (median, 151 vs. 138 omega, 22 vs. 14 omega, and 14.4% vs. 9.9%; p < .001), but the initial and mean CF did not differ. At optimal cutoffs of 21 omega and 10.8% for the absolute and percentage LI drops according to the receiver-operating characteristic analysis, the sensitivity, and specificity for predicting an effective ablation were 57.4% and 88.9% and 80.0%, and 61.1%, respectively. Conclusions: The effective sites during the CF-guided CTI-RFCA had greater initial LI and LI drops than the ineffective sites. Absolute and percentage LI drops of 21 omega and 10.8% may be appropriate targets for an effective ablation.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 50 条
[21]   Insight into contact force local impedance technology for predicting effective pulmonary vein isolation [J].
Lepillier, Antoine ;
Maggio, Ruggero ;
De Sanctis, Valerio ;
Malacrida, Maurizio ;
Stabile, Giuseppe ;
Zakine, Cyril ;
Champ-Rigot, Laure ;
Anselmino, Matteo ;
Segreti, Luca ;
Dell'Era, Gabriele ;
Garnier, Fabien ;
Mascia, Giuseppe ;
Pandozi, Claudio ;
Dello Russo, Antonio ;
Scaglione, Marco ;
Cosaro, Giuseppe ;
Ferraro, Anna ;
Paziaud, Olivier ;
Maglia, Giampiero ;
Solimene, Francesco .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
[22]   Local impedance-guided radiofrequency ablation with standard and high power: Results of a preclinical investigation [J].
Osei, Kofi ;
Sulkin, Matthew S. ;
Hamann, Jason J. ;
Hughes, Christopher ;
Shuros, Allan ;
Nagy, Tamas ;
Kapa, Suraj ;
Meyers, Jason .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (08) :2060-2068
[23]   Predictors of chronic pulmonary vein reconnections after contact force-guided ablation: importance of completing electrical isolation with circumferential lines and creating sufficient ablation lesion densities [J].
Kohki Nakamura ;
Shigeto Naito ;
Takehito Sasaki ;
Kentaro Minami ;
Yutaka Take ;
Satoru Shimizu ;
Yoshiaki Yamaguchi ;
Toshiaki Yano ;
Michiharu Senga ;
Eiji Yamashita ;
Yoshinao Sugai ;
Koji Kumagai ;
Nobusada Funabashi ;
Shigeru Oshima .
Journal of Interventional Cardiac Electrophysiology, 2016, 47 :321-331
[24]   Interactions of contact force, impedance, and power during repeated atrial arrhythmia ablation after previous atrial fibrillation ablation [J].
Alken, Fares-Alexander ;
Scherschel, Katharina ;
Zhu, Ernan ;
Wafaisade, Bahram ;
Kahle, Ann-Kathrin ;
Meyer, Christian .
HEART RHYTHM, 2025, 22 (06) :1411-1420
[25]   Predictors of chronic pulmonary vein reconnections after contact force-guided ablation: importance of completing electrical isolation with circumferential lines and creating sufficient ablation lesion densities [J].
Nakamura, Kohki ;
Naito, Shigeto ;
Sasaki, Takehito ;
Minami, Kentaro ;
Take, Yutaka ;
Shimizu, Satoru ;
Yamaguchi, Yoshiaki ;
Yano, Toshiaki ;
Senga, Michiharu ;
Yamashita, Eiji ;
Sugai, Yoshinao ;
Kumagai, Koji ;
Funabashi, Nobusada ;
Oshima, Shigeru .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 47 (03) :321-331
[26]   Optimized radiofrequency lesions through local impedance guidance for effective CTI ablation in right atrial flutter [J].
Ducceschi, Valentino ;
Zingarini, Gianluca ;
Nigro, Gerardo ;
Brasca, Francesco Maria Angelo ;
Malacrida, Maurizio ;
Carbone, Angelo ;
Lavalle, Carlo ;
Maglia, Giampiero ;
Infusino, Tommaso ;
Aloia, Antonio ;
Nicolis, Daniele ;
Auricchio, Claudia ;
Uccello, Ambra ;
Notaristefano, Francesco ;
Rago, Anna ;
Botto, Giovanni Luca ;
Esposito, Luca .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (05) :612-618
[27]   Recurrent atrial arrhythmia in a randomised controlled trial comparing contact force-guided and contact force-blinded ablation for typical atrial flutter [J].
Giehm-Reese, Mikkel ;
Kronborg, Mads Brix ;
Lukac, Peter ;
Kristiansen, Steen Buus ;
Jensen, Henrik Kjaerulf ;
Gerdes, Christian ;
Kristensen, Jens ;
Nielsen, Jan Moller ;
Nielsen, Jens Cosedis .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 63 (03) :699-707
[28]   The effect of contact force during radiofrequency catheter ablation using a vibrating catheter: New cooling method for catheter ablation [J].
Yu, Kaihong ;
Yamashita, Tetsui ;
Shingyochi, Shigeaki ;
Matsumoto, Kazuo ;
Komiya, Atsuki ;
Ohta, Makoto .
TECHNOLOGY AND HEALTH CARE, 2019, 27 (06) :589-601
[29]   The non-fluoroscopic navigation reduces significantly not only the fluoroscopic exposure during catheter ablation of the cavotricuspid isthmus but the total radiofrequency time as well [J].
Shalganov, Tchavdar ;
Stoyanov, Milko ;
Kunev, Boyan .
ACTA CARDIOLOGICA, 2017, 72 (02) :167-171
[30]   Higher power achieves greater local impedance drop, shorter ablation time, and more transmural lesion formation in comparison to lower power in local impedance guided radiofrequency ablation of atrial fibrillation [J].
Yamashita, Shu ;
Mizukami, Akira ;
Ono, Maki ;
Hiroki, Jiro ;
Miyakuni, Shota ;
Ueshima, Daisuke ;
Matsumura, Akihiko ;
Miyazaki, Shinsuke ;
Sasano, Tetsuo .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (09) :1869-1877