Optimization of DCE-MRI protocol for the assessment of patients with brain tumors

被引:5
作者
Artzi, Moran [1 ,2 ]
Liberman, Gilad [1 ,3 ]
Nadav, Guy [1 ,4 ]
Blumenthal, Deborah T. [5 ]
Bokstein, Felix [5 ]
Aizenstein, Orna [1 ]
Ben Bashat, Dafna [1 ,2 ,6 ]
机构
[1] Tel Aviv Sourasky Med Ctr, Funct Brain Ctr, Wohl Inst Adv Imaging, 6 Weizmann St, IL-64239 Tel Aviv, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Weizmann Inst Sci, Dept Chem Phys, Rehovot, Israel
[4] Tel Aviv Univ, Fac Engn, Tel Aviv, Israel
[5] Tel Aviv Sourasky Med Ctr, Neurooncol Serv, Tel Aviv, Israel
[6] Tel Aviv Univ, Sagol Sch Neurosci, Tel Aviv, Israel
关键词
Dynamic contrast enhanced MRI (DCE-MRI); Pharmacokinetic parameters (PR); Interstitium to plasma rate constant (k(ep)); Model selection; Brain tumors; CONTRAST-ENHANCED MRI; ARTERIAL INPUT FUNCTION; PHARMACOKINETIC PARAMETERS; BARRIER PERMEABILITY; MODEL SELECTION; ANGIOGENESIS; GLIOBLASTOMA; LEAKAGE; BREAST; CANCER;
D O I
10.1016/j.mri.2016.07.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The interstitium-to-plasma rate constant (k(ep)), extracted from dynamic contrast enhancement (DCE-MRI) MRI data, seems to have an important role in the assessment of patients with brain tumors. This parameter is affected by the slow behavior of the system, and thus is expected to be highly dependent on acquisition duration. The aim of this study was to optimize the scan duration and protocol of DCE-MRI for accurate estimation of the k(ep) parameter in patients with high grade brain tumors. The effects of DCE-MRI scan duration and protocol design (continuous vs integrated scanning) on the estimated pharmacokinetic (PK) parameters and on model selection, were studied using both simulated and patient data. Scan duration varied, up to 60 min for simulated data, and up to 25 min in 25 MRI scans obtained from patients with high grade brain tumors, with continuous and integrated scanning protocols. Converging results were obtained from simulated and real data. Significant effect of scan duration was detected on k(ep). Scan duration of 9 min, with integrated protocol in which the data are acquired continuously for 5 min, and additional volumes at 7 and 9 min, was sufficient for accurate estimation of even low k(ep) values, with an average error of 3%. Over-estimation of the PR parameters was detected for scan duration <12 min, being more pronounced at low k(ep) values (<0.1 min(-1)). For the model selection maps, significantly lower percentage of the full extended-Tofts-model (ETM) was selected in patients at scan duration of 5 min compared to >12 min. An integrated protocol of 9 min is suggested as optimal for clinical use in patients with high grade brain tumors: Lower acquisition time may result in over-estimation of k(ep) when using ETM, and therefore care should be taken using model selection. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1242 / 1247
页数:6
相关论文
共 28 条
  • [1] The precision of pharmacokinetic parameters in dynamic contrast-enhanced magnetic resonance imaging: the effect of sampling frequency and duration
    Aerts, Hugo J. W. L.
    Jaspers, K.
    Backes, Walter H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17) : 5665 - 5678
  • [2] Differentiation between treatment-related changes and progressive disease in patients with high grade brain tumors using support vector machine classification based on DCE MRI
    Artzi, Moran
    Liberman, Gilad
    Nadav, Guy
    Blumenthal, Deborah T.
    Bokstein, Felix
    Aizenstein, Orna
    Ben Bashat, Dafna
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2016, 127 (03) : 515 - 524
  • [3] Dynamic Contrast-Enhanced Magnetic Resonance Imaging-Derived kep as a Potential Biomarker of Matrix Metalloproteinase 9 Expression in Patients With Glioblastoma Multiforme: A Pilot Study
    Awasthi, Rishi
    Pandey, Chandra M.
    Sahoo, Prativa
    Behari, Sanjay
    Kumar, Vijendra
    Kumar, Shaleen
    Misra, Shagun
    Husain, Nuzhat
    Soni, Priyanka
    Rathore, Ram K. S.
    Gupta, Rakesh Kumar
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (01) : 125 - 130
  • [4] Model selection for DCE-T1 studies in glioblastoma
    Bagher-Ebadian, Hassan
    Jain, Rajan
    Nejad-Davarani, Siamak P.
    Mikkelsen, Tom
    Lu, Mei
    Jiang, Quan
    Scarpace, Lisa
    Arbab, Ali S.
    Narang, Jayant
    Soltanian-Zadeh, Hamid
    Paudyal, Ramesh
    Ewing, James. R.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 241 - 251
  • [5] Committee RQD-MT DCE MRI Technical Committee, 2012, DCI MRI QUANT PROF Q
  • [6] Accurate determination of blood brain barrier permeability using dynamic contrast-enhanced T1-weighted MRI: a simulation and in vivo study on healthy subjects and multiple sclerosis patients
    Cramer, Stig P.
    Larsson, Henrik B. W.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2014, 34 (10) : 1655 - 1665
  • [7] Cuenod C A, 2013, Diagn Interv Imaging, V94, P1187, DOI 10.1016/j.diii.2013.10.010
  • [8] High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2
    Deoni, SCL
    Peters, TM
    Rutt, BK
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) : 237 - 241
  • [9] The accuracy of pharmacokinetic parameter measurement in DCE-MRI of the breast at 3 T
    Di Giovanni, P.
    Azlan, C. A.
    Ahearn, T. S.
    Semple, S. I.
    Gilbert, F. J.
    Redpath, T. W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01) : 121 - 132
  • [10] Model selection in magnetic resonance imaging measurements of vascular permeability: Gadomer in a 9L model of rat cerebral tumor
    Ewing, JR
    Brown, SL
    Lu, M
    Panda, S
    Ding, GL
    Knight, RA
    Cao, Y
    Jiang, Q
    Nagaraja, TN
    Churchman, JL
    Fenstermacher, JD
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2006, 26 (03) : 310 - 320