Methods of Joint Stiffness Measurement Using a Manually Actuated Dynamometer

被引:0
作者
Kutilek, Patrik [1 ,2 ]
Volf, Petr [1 ]
Hybl, Jan [1 ]
Hejda, Jan [1 ]
Viteckova, Slavka [1 ]
Krivanek, Vaclav [2 ]
Doskocil, Radek [2 ]
Smrcka, Pavel [1 ]
机构
[1] Czech Tech Univ, Fac Biomed Engn, Sitna Sq, Kladno 3105, Czech Republic
[2] Univ Def, Fac Mil Technol, Kounicova 65, Brno, Czech Republic
来源
MECHATRONICS 2019: RECENT ADVANCES TOWARDS INDUSTRY 4.0 | 2020年 / 1044卷
关键词
Joint stiffness; Muscle myotonia; Dynamometer; Angular movement; Torque; Muscle; MUSCLE; RELIABILITY; SPASTICITY; TORQUE;
D O I
10.1007/978-3-030-29993-4_16
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The methods described provide for quantitative evaluation of skeletal muscles' passive resistance, also known as muscle stiffness, muscle myotonia or spasticity. They are employed in the quantitative evaluation of muscle groups responsible for angular movements in the elbow joint. The methods, along with the manually actuated dynamometer, represent an alternative to current evaluation methods which are considered inaccurate and subjective. The function of the electronic dynamometer subsystem is to measure angle and torque in the elbow joint. Stiffness can be evaluated by a graph of the torque moment and joint angle in mutual dependence. Since the curve of dependence demonstrates a relation between the torque moment and joint angle is composed of three parts (small, mean, and high angles), three polynomial equations for three regression lines must be calculated. This means that for three regression lines, three values of joint stiffness are obtained. Angular velocity of the rotational movement in a joint is the result of movement affected by a manually controlled lever of dynamometer. No statistically significant difference in joint stiffness values was identified, when comparing values for individual joint stiffness across three different groups of angular velocities; however, when the same comparison was made for small, mean and high angles, a statistically significant difference was identified for all three angular velocities used. The experiments with healthy subjects confirmed, that the torsional moment is dependent on the elbow angle, not on the velocity of the movement. Finding a correlation between a passive moment of force and kinematic angular parameters allows for the study of a complex movement in a joint.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 50 条
[21]   InvestIgatIon of WeldIng forces and torque MeasureMent usIng octagonal rIng dynaMoMeter In refIll frIctIon stIr spot WeldIng of pure copper [J].
Xiaole, G.E. ;
Kolupaev, I.N. ;
Jiang, Di ;
Wang, Hongfeng .
Archives of Metallurgy and Materials, 2025, 70 (02) :539-552
[22]   Improving Measurement of Hip Joint Center Location Using Neural Networks [J].
Abdulrahman, Alan ;
Iqbal, Kamran .
2014 Middle East Conference on Biomedical Engineering (MECBME), 2014, :342-345
[23]   Direct Measurement of Elbow Joint Angle Using Galvanic Couple System [J].
Chen, Xi Mei ;
Barma, Shovan ;
Pun, Sio Hang ;
Vai, Mang I. ;
Mak, Peng Un .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (04) :757-766
[24]   Objective measurement of Inferior-Directed stiffness in glenohumeral joint using a specially designed robotic device in healthy shoulders; Within- and Between-Session reliability [J].
Azarsa, Mohammad Hassan ;
Mirbagheri, Alireza ;
Hosseini, Seyed Ramezan ;
Shadmehr, Azadeh ;
Karimi, Noureddin .
JOURNAL OF BIOMECHANICS, 2021, 127
[25]   Measurement of passive ankle stiffness in subjects with chronic hemiparesis using a novel ankle robot [J].
Roy, Anindo ;
Krebs, Hermano I. ;
Bever, Christopher T. ;
Forrester, Larry W. ;
Macko, Richard F. ;
Hogan, Neville .
JOURNAL OF NEUROPHYSIOLOGY, 2011, 105 (05) :2132-2149
[26]   Patterns of lower limb muscular activity and joint moments during directional efforts using a static dynamometer [J].
Mathieu Lalumiere ;
Cloé Villeneuve ;
Cassandra Bellavance ;
Michel Goyette ;
Daniel Bourbonnais .
BMC Biomedical Engineering, 2 (1)
[27]   Reliability of a new stabilization device for measurement of muscle strength using a hand-held dynamometer [J].
Yasaci, Zeynal ;
Argut, Sezen Karaborklu ;
Celik, Derya .
MUSCLE & NERVE, 2024, 70 (06) :1240-1246
[28]   Reliability and validity of eccentric strength measurement of the shoulder abductor muscles using a hand-held dynamometer [J].
Karabay, Damla ;
Yesilyaprak, Sevgi Sevi ;
Picak, Gonca Sahiner .
PHYSICAL THERAPY IN SPORT, 2020, 43 :52-57
[29]   Fiber Bragg Grating Sensors for Clinical Measurement of the First Metatarsophalangeal Joint Quasi-Stiffness [J].
Kong, Pui Wah ;
Chan, Chi Chiu ;
Heng, Marabelle Liwen ;
Liu, Yimin ;
Leow, Yixuan ;
Fong, Daniel T. P. .
IEEE SENSORS JOURNAL, 2020, 20 (03) :1322-1328
[30]   Methods for the Identification of Time-Varying Hammerstein Systems with Applications to the Study of Dynamic Joint Stiffness [J].
Tehrani, Ehsan Sobhani ;
Golkar, Mahsa A. ;
Guarin, Diego L. ;
Jalaleddini, Kian ;
Kearney, Robert E. .
IFAC PAPERSONLINE, 2015, 48 (28) :1023-1028