Estimation of ultrasound attenuation from broadband echo-signals using bandpass filtering

被引:5
作者
Kim, Hyungsuk [1 ]
Zagzebski, James A. [1 ]
Varghese, Tomy [1 ]
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
关键词
D O I
10.1109/TUFFC.2008.768
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A problem with video signal analysis for estimating frequency-dependent ultrasonic attenuation is that relative echogenicity versus depth curves are distorted when broadband pulses are used. In this correspondence, we present results that demonstrate improved accuracy of attenuation estimates computed from B-mode or envelope data derived after narrowband (1 MHz BW) filtering at different frequencies around the center frequency of the broadband echo signal. Based on the premise that transducer center frequencies are selected in part on penetration or imaging depth requirements, simulation and experimental results for a typical ultrasound imaging system show that narrowband video signal analysis for frequencies lower than or at the center frequency of the broadband pulse provide unbiased attenuation estimation over this depth. Filtered signals above the center frequency of the pulse yield accurate results only at shallow depths.
引用
收藏
页码:1153 / 1159
页数:7
相关论文
共 22 条
[1]   GLOBAL BREAST ATTENUATION - CONTROL-GROUP AND BENIGN BREAST DISEASES [J].
BERGER, G ;
LAUGIER, P ;
THALABARD, JC ;
PERRIN, J .
ULTRASONIC IMAGING, 1990, 12 (01) :47-57
[2]   A BEAM CORRECTED ESTIMATION OF THE FREQUENCY-DEPENDENT ATTENUATION OF BIOLOGICAL TISSUES FROM BACKSCATTERED ULTRASOUND [J].
CLOOSTERMANS, MJTM ;
THIJSSEN, JM .
ULTRASONIC IMAGING, 1983, 5 (02) :136-147
[3]   ULTRASONIC SIGNAL-PROCESSING FOR INVIVO ATTENUATION MEASUREMENT - SHORT-TIME FOURIER-ANALYSIS [J].
FINK, M ;
HOTTIER, F ;
CARDOSO, JF .
ULTRASONIC IMAGING, 1983, 5 (02) :117-135
[4]   SPECTRAL CHARACTERIZATION AND ATTENUATION MEASUREMENTS IN ULTRASOUND [J].
FLAX, SW ;
PELC, NJ ;
GLOVER, GH ;
GUTMANN, FD ;
MCLACHLAN, M .
ULTRASONIC IMAGING, 1983, 5 (02) :95-116
[5]   APPLICATION OF STOCHASTIC-ANALYSIS TO ULTRASONIC ECHOES - ESTIMATION OF ATTENUATION AND TISSUE HETEROGENEITY FROM PEAKS OF ECHO ENVELOPE [J].
HE, P ;
GREENLEAF, JF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1986, 79 (02) :526-534
[6]   ULTRASOUND ATTENUATION ESTIMATION IN SOFT-TISSUE USING THE ENTROPY DIFFERENCE OF PULSED ECHOES BETWEEN 2 ADJACENT ENVELOPE SEGMENTS [J].
JANG, HS ;
SONG, TK ;
PARK, SB .
ULTRASONIC IMAGING, 1988, 10 (04) :248-264
[7]   Attenuation and backscatter estimation using video signal analysis applied to B-mode images [J].
Knipp, BS ;
Zagzebski, JA ;
Wilson, TA ;
Dong, F ;
Madsen, EL .
ULTRASONIC IMAGING, 1997, 19 (03) :221-233
[8]  
KUC R, 1985, ULTRASONIC IMAGING, V7, P244, DOI 10.1016/0161-7346(85)90004-5
[9]   BOUNDS ON ESTIMATING THE ACOUSTIC ATTENUATION OF SMALL TISSUE REGIONS FROM REFLECTED ULTRASOUND [J].
KUC, R .
PROCEEDINGS OF THE IEEE, 1985, 73 (07) :1159-1168
[10]   A frequency domain model for generating B-mode images with array transducers [J].
Li, YD ;
Zagzebski, JA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (03) :690-699