Influence of corneal thickness on comparative intraocular pressure measurements with goldmann and non-contact tonometers in keratoconus

被引:0
作者
Silih, MS [1 ]
Hawlina, M [1 ]
机构
[1] Univ Eye Clin, Med Ctr, Ljubljana 1000, Slovenia
关键词
Goldmann tonometry; non-contact tonometry; corneal thickness; keratoconus;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The influence of corneal thickness and curvature on the difference between intraocular pressure (IOP) measurements obtained with non-contact (NCT) and those with the Goldmann applanation tonometer (GAT) was studied in patients with keratoconus. Materials and methods: We examined 113 patients with keratoconus. IOP was measured by the Canon TX 10 non-contact tonometer and the Goldmann tonometer, corneal curvature and thickness were obtained by Humphrey Automatic Refractometer Keratometer and Orbscan Version 3.0 Bausch & Lomb Surgical. Results: The IOP measured by NCT was significantly lower than that measured by GAT. The mean pachymetry of the thinnest point was 423.15 +/- 98.43 mum for the right eyes and 426.7 +/- 93.88 mum for the left eyes. The difference between NCT-GAT and corneal thickness showed a significant negative correlation (r = -0.427, p < 0.0001; t = -3.677, p < 0.0001). Values of NCT measurements were significantly increasing with corneal thickness (F = 6.505, p < 0.0001 for right eyes and F = 4.37, p = 0.004 for left eyes), whilst GAT measurements did not show a significant influence of the corneal thickness. The keratometry had no effect on the difference between NCT-GAT measurements (t = 1.090, p = 0.278). Conclusions: The thin cornea has more influence on the measurement with NCT than GAT. The relative precision of NCT compared with GAT seems to be influenced by the corneal thickness.
引用
收藏
页码:843 / 847
页数:5
相关论文
共 25 条
[1]   Tono-Pen determination of intraocular pressure in patients with band keratopathy or glued cornea [J].
Azuara-Blanco, A ;
Bhojani, TK ;
Sarhan, AR ;
Pillai, CT ;
Dua, HS .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (06) :634-636
[2]   The effects of changed biomechanical parameters on measurements of intraocular pressure in keratoconus patients [J].
Bohm, A ;
Kohlhaas, M ;
Lerche, RC ;
Bischoff, B ;
Richard, G .
OPHTHALMOLOGE, 1997, 94 (11) :771-774
[3]   OCULAR RIGIDITY AND INTRAOCULAR-PRESSURE IN KERATOCONUS [J].
BROOKS, AMV ;
ROBERTSON, IF ;
MAHONEY, AM .
AUSTRALIAN JOURNAL OF OPHTHALMOLOGY, 1984, 12 (04) :317-324
[4]  
Budu, 2000, JPN J OPHTHALMOL, V44, P610
[5]  
Copt RP, 1999, ARCH OPHTHALMOL-CHIC, V117, P14
[6]   Influence of corneal variables on accuracy of intraocular pressure measurement [J].
Damji, KF ;
Muni, RH ;
Munger, RM .
JOURNAL OF GLAUCOMA, 2003, 12 (01) :69-80
[7]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[8]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[9]   Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques:: Reykjavik Eye Study [J].
Eysteinsson, T ;
Jonasson, F ;
Sasaki, H ;
Arnarsson, A ;
Sverrisson, T ;
Sasaki, K ;
Stefánsson, E .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2002, 80 (01) :11-15
[10]   Central corneal thickness and intraocular pressure in a Mongolian population [J].
Foster, PJ ;
Baasanhu, J ;
Alsbirk, PH ;
Munkhbayar, D ;
Uranchimeg, D ;
Johnson, GJ .
OPHTHALMOLOGY, 1998, 105 (06) :969-973