Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques
被引:162
作者:
Park, MC
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USAColumbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USA
Park, MC
[1
]
Cadet, ER
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USAColumbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USA
Cadet, ER
[1
]
Levine, WN
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USAColumbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USA
Levine, WN
[1
]
Bigliani, LU
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USAColumbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USA
Bigliani, LU
[1
]
Ahmad, CS
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USAColumbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USA
Ahmad, CS
[1
]
机构:
[1] Columbia Univ, Ctr Shoulder Elbow & Sports Med, Dept Orthopaed Surg, New York, NY 10032 USA
Background: Interface contact pressure between the tendon and bone has been shown to influence healing. This study evaluates the interface pressure of the rotator cuff tendon to the greater tuberosity for different rotator cuff repair techniques. Hypothesis: The transosseous tunnel rotator cuff repair technique provides larger pressure distributions over a defined insertion footprint than do suture anchor techniques. Study Design: Controlled laboratory study. Methods: Simulated rotator cuff tears over a 1 x 2-cm infraspinatus insertion footprint were created in 25 bovine shoulders. A transosseous tunnel simple suture technique (n = 8), suture anchor simple technique (n = 9), and suture anchor mattress technique (n = 8) were used for repair. Pressurized contact areas and mean pressures of the repaired tendon against the tuberosity were determined using pressure-sensitive film placed between the tendon and the tuberosity. Results: The mean contact area between the tendon and tuberosity insertion footprint was significantly greater for the transosseous technique (67.7 + 5.8 mm(2)) compared with the suture anchor simple (34.1 +/- 9.4 mm(2)) and suture anchor mattress (26.0 +/- 5.3 mm(2)) techniques (P < .05). The mean interface pressure exerted over the footprint by the tendon was also greater for the transosseous technique (0.32 +/- 0.05 MPa) compared with the suture anchor simple (0.26 +/- 0.04 MPa) and suture anchor mattress (0.24 +/- 0.02 MPa) techniques (P < .05). Conclusion: The transosseous tunnel rotator cuff repair technique creates significantly more contact and greater overall pressure distribution over a defined footprint when compared with suture anchor techniques. Clinical Relevance: Stronger and faster rotator cuff healing may be expected when beneficial pressure distributions exist between the repaired rotator cuff and its insertion footprint. Tendon-to-tuberosity pressure and contact characteristics should be considered in the development of improved open and arthroscopic rotator cuff repair techniques.
机构:
Mayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USAMayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
Lee, SB
;
Itoi, E
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USAMayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
Itoi, E
;
O'Driscoll, SW
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USAMayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
O'Driscoll, SW
;
An, KN
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USAMayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
机构:
Mayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USAMayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
Lee, SB
;
Itoi, E
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USAMayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
Itoi, E
;
O'Driscoll, SW
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USAMayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
O'Driscoll, SW
;
An, KN
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USAMayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA